  • Page 4 Note Before you use this information and the product it supports, refer to the safety information in the IBM BladeCenter HS23 Types 7875 and 1929: Problem Determination and Service Guide and read the general information under Notices in this document.
  • Page 5: Table Of Contents

    Preface ....xv Removing and replacing blade server components ... . . 1 Before you go to a customer . © Copyright IBM Corp. 2010, 2014...
  • Page 6 Problem Determination and Service Guide Addendum...
  • Page 7: Safety

    Vor der Installation dieses Produkts die Sicherheitshinweise lesen. Greek Hebrew Hungarian Italian Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza. Japanese Korean Macedonian Norwegian Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet. © Copyright IBM Corp. 2010, 2014...
  • Page 8: Guidelines For Trained Technicians

    Use good judgment to identify potential unsafe conditions that might be caused by attachment of non-IBM features or options that are not addressed in this section. If you identify an unsafe condition, you must determine how serious the hazard is and whether you must correct the problem before you work on the product.
  • Page 9: Guidelines For Servicing Electrical Equipment

    Make sure that the insulation is not frayed or worn. 4. Remove the cover. 5. Check for any obvious non-IBM alterations. Use good judgment as to the safety of any non-IBM alterations. 6. Check inside the system for any obvious unsafe conditions, such as metal filings, contamination, water or other liquid, or signs of fire or smoke damage.
  • Page 10: Safety Statements

    v To ensure proper grounding of components such as power supplies, pumps, blowers, fans, and motor generators, do not service these components outside of their normal operating locations. v If an electrical accident occurs, use caution, turn off the power, and send another person to get medical aid.
  • Page 11 Statement 1 DANGER Electrical current from power, telephone, and communication cables is hazardous. To avoid a shock hazard: v Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. v Connect all power cords to a properly wired and grounded electrical outlet. v Connect to properly wired outlets any equipment that will be attached to this product.
  • Page 12 Statement 2 CAUTION: When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer.
  • Page 13 Statement 3 CAUTION: When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or transmitters) are installed, note the following: v Do not remove the covers. Removing the covers of the laser product could result in exposure to hazardous laser radiation. There are no serviceable parts inside the device.
  • Page 14 Statement 8 CAUTION: Never remove the cover on a power supply or any part that has the following label attached. Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components.
  • Page 15 Statement 13 DANGER Overloading a branch circuit is potentially a fire hazard and a shock hazard under certain conditions. To avoid these hazards, ensure that your system electrical requirements do not exceed branch circuit protection requirements. Refer to the information that is provided with your device for electrical specifications.
  • Page 16 Statement 33 CAUTION: This device does not provide a power control button. Removing power supply modules or turning off the server blades does not turn off the electrical current supplied to the device. The device also might have more than one power cord. To remove all electrical current from the device, ensure that all power cords are disconnected from the power source.
  • Page 17: Preface

    BladeCenter Type 7875-AC1. Note: The BoMCsft or BoMCSft2 tool cannot be used by the IBM SSR to support this product. See the field-reflash procedure, which allows the firmware to be updated and the VPD to be set.
  • Page 18 Problem Determination and Service Guide Addendum...
  • Page 19: Removing And Replacing Blade Server Components

    Before you begin, you must understand the importance of the field-reflash. Read the following information: v IBM WebSphere DataPower Integration Blade XI52B appliances have a USB flash key that is plugged into the system board of the device. This key is referred to as the internal key.
  • Page 20: Creating The Service Key

    After you install a new internal key in the blade appliance, you must return the old internal key to IBM. The customer can reformat the old internal key to erase any sensitive data as required by their local policy. Ensure that you follow all packaging instructions and use any packaging materials that are supplied to you.
  • Page 21 Obtain the Win32 Disk Imager tool or any other tool that can create a bootable USB key. – You can get a copy of Win32 Disk Imager at http://ausgsa.ibm.com/ projects/i/ima_support/downloads/bootableISOs/. – Win32 Disk Imager is an open source project on SourceForge at http://sourceforge.net/projects/win32diskimager/.
  • Page 22: Field-Reflashing The Internal Key

    About this task For instruction on removing and installing the internal USB flash key or the system board, see the IBM BladeCenter HS23 Types 7875 and 1929: Problem Determination and Service Guide. The service key comes with a password that must be used to complete the reflash operation.
  • Page 23 7. From the IBM System x screen, select <F1> Setup. 8. From the System Configuration and Boot Management screen, select Load Default Settings. Removing and replacing blade server components...
  • Page 24 9. After the load default settings process completes, select Save Settings. 10. Select Boot Manager and then Add Boot Option. From this panel, select Platform Specific Boot Device. Problem Determination and Service Guide Addendum...
  • Page 25 11. Select USB0 – USB Port0 Hypervisor. 12. Select the Description field, and for description enter USB Port0 Hypervisor as shown. Removing and replacing blade server components...
  • Page 26 13. With the description in place, select Commit Changes and press Enter. 14. Press Esc to return to the Boot Manager panel and then Add WOL Boot Option. From this panel, select Platform Specific Boot Device. Again, choose USB0 – USB Port0 Hypervisor. Problem Determination and Service Guide Addendum...
  • Page 27 15. The description is already provided. Select Commit Changes and press Enter. 16. Press Esc to return to the Boot Manager panel. Select Delete Boot Option. On this panel, press Space to select each of the boot options except USB Port0 Hypervisor.
  • Page 28 17. Press Esc to return to the Boot Manager panel. Select Delete WOL Boot Option. On this panel, press Space to select each of the boot options except USB Port0 Hypervisor. Position the cursor at Commit Changes and press Enter. 18.
  • Page 29 BladeCenter chassis. 20. Press Enter and the appliance boots from the service key. The system reboots one or more times. The IBM System x screen might appear again. Let it time out and proceed.
  • Page 30 26. When the DataPower login screen displays, check the firmware version of the blade appliance in the AMM (select Monitors > Firmware VPD). For more information, see the IBM BladeCenter Advanced Management Module User's Guide. You should see versions at this level or higher.
  • Page 31 After you complete this procedure, notify the customer administrator contact that the appliance is ready to be verified and receive initial configuration through remote serial access. Note: The customer must contact IBM Support to confirm that the licenses are correctly displayed on the repaired appliance. Related tasks: “Creating the service key”...
  • Page 32 Problem Determination and Service Guide Addendum...
  • Page 33: Notices

    Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead.
  • Page 34 Problem Determination and Service Guide Addendum...

Table of Contents