2 Removal and installation / 2.2 Removing the turbocharger
2.2

Removing the turbocharger

WARNING
Risk of tipping
If the turbocharger is not sufficiently supported or not supported at all dur-
ing removal and installation, it may tip over and cause severe injury to per-
sonnel or accidents resulting in fatalities.
Support the turbocharger at a suitable location.
u
Secure with lifting gear wherever possible.
u
Wear safety helmet.
If present: Loosen cable to speed sensor.
u
Disconnect all gas, air and lubricating oil pipes.
u
Fig. 6: Turbocharger suspension points
If present: Remove insulation segments on bearing casing and feet.
u
Attach lifting gear to the suspension lug of the bearing casing and through the boles on
u
the turbine-end foot.