2.
3.
4.
2.4.2
Connecting DC Power
To connect a high or low DC power supply to the device, do the following:
Electrical hazard – risk of damage to equipment
Before testing the dielectric strength (HIPOT) in the field, remove the braided
ground cable connected to the surge ground terminal and chassis ground. This cable
connects transient suppression circuitry to chassis ground and must be removed in
order to avoid damage to transient suppression circuitry during testing.
1.
RUGGEDCOM RS1600T
Installation Manual, 11/2022, C79000-G8976-1015-04
Braided Ground Cable
4
Figure 2.4
Terminal Block Wiring
Connect the negative wire from the power source to the negative/neutral (-/N)
terminal on the terminal block.
Using a braided wire or other appropriate grounding wire, connect the surge
ground terminal to the chassis ground connection. The surge ground terminal
is used as the ground conductor for all surge and transient suppression circuitry
internal to the unit.
Connect the ground terminal on the power source to the chassis ground
terminal on the device.
NOTICE
Connect the positive wire from the power source to the positive/hot (+/
H) terminal on the terminal block. For more information, refer to
Examples" (Page
14).
1
2
3
Positive/Hot (+/H) Terminal
1
Negative/Neutral (-/N) Terminal
2
Surge Ground Terminal
3
Installing Device
2.4.2 Connecting DC Power
"Wiring
4
13