hit counter script

Expansion Card -Synqnet; Front View; Node Id Switch; Node Led Table - Danaher Motion Kollmorgen SERVOSTAR 300 Series Assembly, Installation, Setup

Digital servo amplifier
Table of Contents

Advertisement

Expansions and Accessories
6.1.7

Expansion card -SYNQNET-

This section describes the SynqNet expansion card for SERVOSTAR 300.
Information on the range of functions and the software protocol can be found in the
SynqNet documentation.
If you ordered the expansion card together with the servo amplifier, then the expansion
card is already fitted and screwed into the slot when the servo amplifier is delivered.
6.1.7.1

Front view

6.1.7.2

NODE ID Switch

With these hexadecimal switches you can set the main and low significant bytes of the
Node ID seperately. SynqNet does not require an address for correct operation in the net-
work, however in some machines this can be a convenient way of identifying build options
to the application program.
6.1.7.3

Node LED table

LED#
LED1
LED2
LED3
LED4
6.1.7.4

SynqNet Connection, Connector X21B/C (RJ-45)

Connection to the SynqNet network via RJ-45 connectors (IN and OUT ports) with inte-
grated LEDs.
86
12/05
Name
Function
ON = receive valid (IN port)
LINK_IN
OFF= not valid, power off, or reset.
ON = network cyclic
CYCLIC
BLINK = network not cyclic
OFF = power off, or reset
ON = receive valid (OUT port)
LINK_OUT
OFF = not valid, power off, or reset
ON = repeater on, network cyclic
REPEATER
BLINK = repeater on, network not cyclic
OFF = repeater off, power off, or reset
LED2 LED1
®
SERVOSTAR
300 Installation Manual
Kollmorgen
LED4 LED3

Advertisement

Table of Contents
loading

Table of Contents