Summary of Contents for KARSUN JS-Y001

  • Page 1 Flap Turnstile manual book MODEL: JS-Y001...
  • Page 2: Chapter 1 - Products Specification

    Chapter 1 – Products specification 1.1. Product specifications The JS-Y001 flap turnstiles have the following characteristics: Power requirements: 110V -220V, 250W to 500W. The swing turnstiles are provided with different power supplies, based on country and customer’s requirements. Check the product label before connecting to any power supply.
  • Page 3 Chapter 2 – INSTALLATION Before proceeding to the installation of the turnstile, unpack all components and checkto make sure the all parts from the packing slip are included, verify dimensions and conduit runs. Use the turnstile template to properly align and lay out the site and to determine the right location of the floor stub-ups and anchors.
  • Page 4: Chapter 3 - Cable Connecting

    Warning The depth of buried PVC pipes should be greater than 60mm, and the height of exposed ground should be greater than 50mm. And the outlet is bent back to prevent water from entering the line pipe When installing access gates, the left and right gates of each channel should be aligned; Connect the system protection ground wire;...
  • Page 5 3.3 Cable connecting Please pay attention that these sync cable color should match each other like bellow photo Step : 1. connected sync cable main board to slave board as bellow 2. connected internet cable to main board and slave board as bellow ( internet cable between main board and slave board for sync the infrared sensor ) 3.
  • Page 6: Chapter 4 - Main-Board Features

    Chapter 4 – Main-board Features This control board is suitable for the control of wing gates, swing gates andquick-pass gates equipped with DC brushless motors. 1. This control board adopts ARM embedded system as the core of control. It has the advantages of faster processing speed, more powerful function expansion andmore stable performance.
  • Page 7 Chapter 5 5.1 Main board wiring diagram...
  • Page 8 5.2 Main-board parameter setting operation flow operating procedures: After the Long press the Press the menu key to press+/- Select parameters are enter the parameter menu key till to the set, press the adjustment options, see L-1 enter corresponding confirmation press +/ - to adjust the menu list menu option...
  • Page 9 0-41 Right pass voice Infrared superimposition time (in seconds) 0-30 Power failure opening direction 0 for: left open 1 for: right open Alarm voice 0 for: trespassing please swipe card 13 for: dripping sound Entrance/exit memory function 0 for: without memory function configuration 1 representative: with memory function 0 for: Emergency stop + door opening...
  • Page 10 The higher the value, the earlier the deceleration Chapter 6– Trouble shooting code meanings Display E-1 :Main Motor Hall Error:adjust L-15 to 1 Display E-2 :Slave Motor Hall Error :adjust L-16 to 1 Unmentioned errors, contact with Karsun team for technical trouble-shooting.
  • Page 11: Chapter 7- Safety Attentions

    Chapter 7– Safety attentions Do not strike the product with hard objects. Handle carefully when using to avoid strong collision with hard objects. The product must not be exposed to water or corrosive liquids. If smoke or odor is found in the product, disconnect the power immediately. If the product is abnormal, please contact the dealer in time.