Siemens FCM20 U2 Series Installation And Mounting Manual

Siemens FCM20 U2 Series Installation And Mounting Manual

Operating unit

Advertisement

Quick Links

FCM20xx-U2, FCM20xx-U3
Operating unit, Operating unit (+ LED module),
Operating unit (+ Switch module)
Installation
Mounting
Smart Infrastructure
A6V10315030_d_en_--
2024-02-14

Advertisement

Table of Contents
loading

Summary of Contents for Siemens FCM20 U2 Series

  • Page 1 FCM20xx-U2, FCM20xx-U3 Operating unit, Operating unit (+ LED module), Operating unit (+ Switch module) Installation Mounting Smart Infrastructure A6V10315030_d_en_-- 2024-02-14...
  • Page 2 Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model or design patent are reserved. Issued by: Siemens Industry, Inc. Smart Infrastructure 2 Gatehall Drive Parsippany, NJ 07054 Tel.
  • Page 3: Table Of Contents

    Table of contents Operating unit FCM20xx ................Description ..................... Mounting and wiring the operating unit ............View of PMI & mainboard................Indicators......................Adjustment elements..................Technical data ....................LED module FTO2008 and LED module (red/yellow, yellow) FTO2018... Description ..................... Views......................Adjustment elements..................Technical data ....................
  • Page 4 4 | 26 2024-02-14 A6V10315030_d_en_--...
  • Page 5: Operating Unit Fcm20Xx

    Operating unit FCM20xx 1 Operating unit FCM20xx Fig. 1: View of FCM2018 operating unit Fig. 2: View of FCM2019 and FCM2035 operating unit (+ LED module) Fig. 3: View of FCM2043 operating unit (+ switch module) A6V10315030_d_en_-- 2024-02-14 5 | 26...
  • Page 6: Description

    Operating unit FCM20xx Description 1.1 Description The operating unit is installed in the panels and comes in different versions: ● FCM2018 operating unit with control and display elements ● FCM2019 operating unit (+LED module) with extra integrated LED module ● FCM2035 operating unit (+LED module) with extra integrated LED module [ULC] ●...
  • Page 7: Mounting And Wiring The Operating Unit

    Operating unit FCM20xx Mounting and wiring the operating unit ● Can be controlled via peripheral data bus for fire detection controls ● Each LED can be configured individually Document references The templates for the inscription strips and the operating instructions with button and LED designations have the following document IDs: Desigo Cerberus PRO...
  • Page 8 Operating unit FCM20xx Mounting and wiring the operating unit FHD2004 Inner door with window Operating unit FCM20xx 4x fixing nut for operating unit 4x set screw for operating unit (welded) Mounting steps 1. Plug the operating unit (2) onto the set screws (4) of the inner door (1) from behind, as shown above.
  • Page 9 Operating unit FCM20xx Mounting and wiring the operating unit DIN rail kit FHA2031 Periphery bus connection on periphery board (X201) Ribbon cable fixing with cable support Peripheral data bus connection on PMI & mainboard (X3) Inner door with FCM2018 operating unit Peripheral data bus output connection to optional LED or switch module Peripheral data bus input connection from PMI &...
  • Page 10: View Of Pmi & Mainboard

    Operating unit FCM20xx View of PMI & mainboard Inscription LEDs Inscription for the standard keys in the center Inscription for standard keys on the right Inscription for LED module (depending on whether operating unit is present or not) Inscription for panel and alarm 1.3 View of PMI &...
  • Page 11: Indicators

    Operating unit FCM20xx Indicators Element Des. Function Plug connections Connection for periphery board or fire terminal board (supply and data signals) Ethernet connection Connection for 18-pin cable to the MXL line card (FCL2004) N.C. Slot for network module SAFEDLINK FN2001 Slot for RS485 class A module (isolated) FCA2016 Not used Slot for RS485 class A module (isolated) FCA2016...
  • Page 12: Adjustment Elements

    Operating unit FCM20xx Adjustment elements Color Function Condition Meaning Yellow 'CPLD fail' (reset and Normal operation watchdog logic) Logic unit failed; replace component or contact hotline 'TEMP', CPU module Normal operation excess temperature CPU >113 °F / 45 °C indicator Yellow 'SPEED', Ethernet Data transfer at 10 Mbit/s transmission indicator Data transfer at 100 Mbit/s H842...
  • Page 13: Technical Data

    Operating unit FCM20xx Technical data ● A6V10315021 for Desigo ● A6V10333434 for Cerberus PRO S33: Switch for ground fault supervision of the Ethernet connection Position Function Default setting Setting for networking via FCnet/C-WEB Setting for networking via Ethernet S38: Switch for ground fault supervision of the system supply ●...
  • Page 14 Operating unit FCM20xx Technical data Interfaces Serial modules ● For class A RS485 module for connecting an external printer or FT2014/FT2015 [X14] and [X19] Internal bus ● For MXL line card (FCL2004) synchronization [X11] Networking ● Network module (SAFEDLINK) incl. degraded mode function [X13] Ethernet ●...
  • Page 15: Led Module Fto2008 And Led Module (Red/Yellow, Yellow) Fto2018

    LED module FTO2008 and LED module (red/yellow, yellow) FTO2018 Description 2 LED module FTO2008 and LED module (red/ yellow, yellow) FTO2018 2.1 Description The LED module FTO2008 and the LED module (red/yellow, yellow) FTO2018 are zone indicators which allow events (e.g., alarms and troubles) from 24 zones to be displayed.
  • Page 16: Views

    LED module FTO2008 and LED module (red/yellow, yellow) FTO2018 Views 2.2 Views H337 H338 H301 H302 H339 H303 H340 H341 H304 H305 H306 H342 H343 H344 H307 H308 H345 H309 H310 H311 H346 H347 H348 H312 H349 H350 H313 H314 H351 H315 H316...
  • Page 17: Adjustment Elements

    LED module FTO2008 and LED module (red/yellow, yellow) FTO2018 Adjustment elements Element Des. Function Indicators H301… LEDs for indication on front (designation on PCB) H371 Switch Switch for device address Connectors X400 Peripheral data bus connection (input) X402 Peripheral data bus connection (output) X407 Not used X409...
  • Page 18: Technical Data

    LED module FTO2008 and LED module (red/yellow, yellow) FTO2018 Technical data 2.4 Technical data Supply input Voltage DC 24 V Operating current Max. 5 mA + 1 mA per LED (max. 48 LEDs) Supply output Voltage DC 24 V Curent Looped, max. 1 A LEDs Quantity 48 LEDs for 24 zones: LED module ●...
  • Page 19: Switch Module Fire/Voice Fto2023

    Switch module Fire/Voice FTO2023 Description 3 Switch module Fire/Voice FTO2023 3.1 Description The 'Switch Module- Fire/Voice' FTO2023 is a programmable control module with 24 'Zones' and can be installed in a fire control panel, Fire voice control panel or in 'Remote microphone' VR2005 'Panels'. An FTO2023 can be used to indicate events, provide status information, and activate fire/voice functions.
  • Page 20: Views

    Switch module Fire/Voice FTO2023 Views ● Each LED may be configured as OFF, flashing, or constantly ON ● Audible confirmation when a button is pressed ● Can be controlled via CAN bus for Fire voice control panels or via peripheral data bus for fire control panels ●...
  • Page 21: Adjustment Elements

    Switch module Fire/Voice FTO2023 Adjustment elements Element Des. Function Indicators H301 Status LED for CAN bus H625 Status LED for microprocessor Switches and S326 Switch for device address (ONES) keys S327 Switch for device address (TENS) S328 Reset button Connector plug X202 Peripheral data bus connector B and jumper...
  • Page 22: Technical Data

    Switch module Fire/Voice FTO2023 Technical data CAN bus addresses between 1 and 99 are valid on the 'Switch Module- Fire/Voice' FTO2023. The hardware addresses set for each module must correspond to the matching addresses 201 to 299 in Desigo Fire Safety Works/Cerberus-Engineering-Tool. The CAN bus address 0 is reserved and must not be used for the option modules.
  • Page 23 Switch module Fire/Voice FTO2023 Technical data CAN bus (input and output) for Fire voice X204, X205 control panels Plug connection with ribbon cable A6V10315030_d_en_-- 2024-02-14 23 | 26...
  • Page 24: Fcc Statement

    FCC Statement 4 FCC Statement WARNING Installation and usage of equipment is not in accordance with instructions manual Radiation of radio frequency energy Interference to radio communications ● Install and use equipment in accordance with instructions manual. ● Read the following information. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions manual, may cause interference to radio communications.
  • Page 25 A6V10315030_d_en_-- 25 | 26...
  • Page 26 Issued by Siemens Industry, Inc. Smart Infrastructure 2 Gatehall Drive Parsippany, NJ 07054 +1 973-593-2600 www.usa.siemens.com/fire © Siemens, 2012 Technical specifications and availability subject to change without notice. A6V10315030_d_en_--...