Adapting
microwave
blower
This microwave is shipped assembled
for Room Venting
Installation. The blower unit is already in place and must
not to be adapted.
Adapting microwave blower for roof venting
1. Remove and save the screws holding the blower
motor and the blower plate. Lift up the blower plate
and put it aside.
2. Carefully pull out the blower unit and rotate 90 ° so that
fan blade openings
are facing out the top of the
microwave.
3. Place the blower unit back into the opening.
CAUTION
Do not pull or stretch the blower unit wiring. Make
sure the wires are not pinched, and that they are
properly secured.
4. Replace the blower plate and secure with the screws
removed in step 1.
m
5. Attach the exhaust adapter to the top of the blower
plate by sliding it into the guides. Push in securely until
it is in the locking tabs. Make sure the damper hinge
swings freely.
1;t
Adapting microwave blower for wall venting
1. Remove and save the screws holding the blower
motor and the blower plate. Lift up the blower plate
and put it aside.
2. Carefully pull out the blower unit and rotate 90 ° so that
fan blade openings
are facing out the top of the
microwave.
3. Rotate the blower unit counterclockwise
180 °.
11