Model(s):
HU161HA U33 / HN1610H NK3
Air-to-water heat pump:
YES
Water-to-water heat pump:
YES
Brine-to-water heat pump:
YES
Low-temperature heat pump:
YES
Equipped with a supplementary heater:
YES
Heat pump combination heater:
YES
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps.
For low- temperature heat pumps, parameters shall be declared for low-temperature application.
Parameters shall be declared for average climate conditions.
Low temperature application
Item
Symbol
Rated heat output (*)
P
Declared capacity for heating for part load at indoor
temperature 20 °C and outdoor temperature T j
T j = – 7 °C
P
T j = + 2 °C
P
T j = + 7 °C
P
T j = + 12 °C
P
T j = bivalent temperature
P
T j = operation limit temperature
P
For air-to-water heat pumps:
P
Tj=-15℃ (if TOL < -20℃)
Bivalent temperature
T
Cycling interval capacity for heating
P
Degradation co-efficient(**)
C
Medium temperature application
Item
Symbol
Rated heat output (*)
P
Declared capacity for heating for part load at indoor
temperature 20 °C and outdoor temperature T j
T j = – 7 °C
P
T j = + 2 °C
P
T j = + 7 °C
P
T j = + 12 °C
P
T j = bivalent temperature
P
T j = operation limit temperature
P
For air-to-water heat pumps:
P
Tj=-15℃ (if TOL < -20℃)
Bivalent temperature
T
Cycling interval capacity for heating
P
Degradation co-efficient(**)
C
Power consumption in modes other than active mode
Off mode
P
Thermostat-off mode
P
Standby mode
P
Crankcase heater mode
P
Other items
Capacity control
Sound power level, indoors/outdoors
L
L
Annual electricity consumption
Q HE, (Low Temp)
(Low Temp)
Annual electricity consumption
Q HE (Mid Temp)
(Mid Temp)
For heat pump combination heater
Declared load profile
Daily elecrictiy consumption
Qelec
Annual electricity consumption
AEC
Name : Christianna Papazahariou
Position : European Regulatory Manager
E-mail address : chris.papazahariou@lge.com Tel. 01 49 89 57 41 – 06 83 077 455
Contact details
Postal address : Paris Nord II – 117 avenue des Nations BP 59372
Villepinte – 95942 Roissy CDG Cedex
www.lg.com
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating
Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
Technical parameters for heat pump space heaters and heat pump combination heaters
NO
NO
NO
NO
NO
NO
Value
Unit
13 kW
rated
11.9 kW
dh
7.0 kW
dh
4.7 kW
dh
4.8 kW
dh
13.5 kW
dh
13.5 kW
dh
x,x kW
dh
-10 ℃
biv
x,x kW
cych
0.9
dh
Value
Unit
11 kW
rated
9.6 kW
dh
5.9 kW
dh
3.7 kW
dh
4.5 kW
dh
10.8 kW
dh
10.8 kW
dh
x,x kW
dh
-10 ℃
biv
x,x kW
cych
0.9
dh
0.060 kW
OFF
0.060 kW
TO
0.060 kW
SB
0.000 kW
CK
Variable
63 dB
WA,indoor
63 dB
WA,Outdoor
8618 kWh
7424 kWh
x
x.xxx
kWh
x kWh
Item
Seasonal space heating energy efficiency
Declared coefficient of performance or primary energy ratio for part load at indoor
temperature 20 °C and outdoor temperature T j
T j = – 7 °C
T j = + 2 °C
T j = + 7 °C
T j = + 12 °C
T j = bivalent temperature
T j = operation limit temperature
For air-to-water heat pumps:
Tj=-15℃ (if TOL < -20℃)
Cycling interval efficiency
Heating water operating limit temperature
Item
Seasonal space heating energy efficiency
Declared coefficient of performance or primary energy ratio for part load at indoor
temperature 20 °C and outdoor temperature T j
T j = – 7 °C
T j = + 2 °C
T j = + 7 °C
T j = + 12 °C
T j = bivalent temperature
T j = operation limit temperature
For air-to-water heat pumps:
Tj=-15℃ (if TOL < -20℃)
For air -to-water heat pumps:
Operation limit temperature
Cycling interval efficiency
Heating water operating limit temperature
Supplementary heater
Rated heat output (*)
Type of energy input
For air-to-water heat pumps:
Rated air flow rate, outdoors (Low Temp)
For air-to-water heat pumps:
Rated air flow rate, outdoors (Mid. Temp)
For water-/brine-to-water heat pumps:
Rated brine or water flow rate,
outdoor heat exchanger
Water Pump EEI
"The benchmark for the most efficient circulators is EEI ≤ 0,20.";
Water heating energy efficiency
Daily fuel consumption
Annual fuel consumption
Symbol
Value
Unit
η
126%
S
COPd or PERd
2.40 – or %
COPd or PERd
3.30 – or %
COPd or PERd
4.20 – or %
COPd or PERd
3.80 – or %
COPd or PERd
2.10 – or %
COPd or PERd
2.10 – or %
COPd or PERd
x,xx – or %
COPcyc or PERcyc
x,xx – or %
WTOL
65 ℃
Symbol
Value
Unit
η
117%
S
COPd or PERd
2.46 – or %
COPd or PERd
3.47 – or %
COPd or PERd
3.00 – or %
COPd or PERd
3.60 – or %
COPd or PERd
2.00 – or %
COPd or PERd
2.00 – or %
COPd or PERd
x,xx – or %
TOL
-15 ℃
COPcyc or PERcyc
x,xx – or %
WTOL
65 ℃
Psup
kW
3.5
Electric
3
7044 m
/h
3
6560 m
/h
x
0.20
η
x %
wh
Qfuel
x,xxx kWh
AFC
x GJ

Advertisement

loading

Summary of Contents for LG HU161HA U33

  • Page 1 Technical parameters for heat pump space heaters and heat pump combination heaters Model(s): HU161HA U33 / HN1610H NK3 Air-to-water heat pump: Water-to-water heat pump: Brine-to-water heat pump: Low-temperature heat pump: Equipped with a supplementary heater: Heat pump combination heater: Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps.
  • Page 2 Warmer climate Low temperature application Item Symbol Value Unit Item Symbol Value Unit Rated heat output (*) 11 kW Seasonal space heating energy efficiency η 118% rated Declared capacity for heating for part load at indoor Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20 °C and outdoor temperature T j temperature 20 °C and outdoor temperature T j T j = + 2 °C...
  • Page 3 IMPORTANT SAFETY INSTRUCTIONS Read the precautions in this manual carefully before operating the unit. This symbol indicates that the Operation Manual should be read carefully. This symbol indicates that a service personnel should be handling this equipment with reference to the Installation Manual. READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
  • Page 4 • Do not modify or extend the power cable. If the power cable or cord has scratches or skin peeled off or deteriorated then it must be replaced. - There is risk of fire or electric shock. • For installation, removal or reinstall , always contact the dealer or an Authorized Service Center.
  • Page 5 • Make sure to check that the power device is not dirty, loose or broken and then turn on the power. - Dirty, loose or broken power device can cause electric shock or fire. • In unit the step-up capacitor supplies high voltage electricity to the electrical components.
  • Page 6 • If you touch the pipe or internal parts, you should be wear protection or wait time to return to normal temperature. - Otherwise , it may cause burns or frostbite, personal injury. • Do not touch leaked refrigerant directly. - There is risk of frostbite.
  • Page 7 - Low refrigerant levels may cause failure of product. • Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer AWHP, not a precision refrigeration system. - There is risk of damage or loss of property. •...
  • Page 8 operation or depending on the amount of hot water. • During floor heating operation it is important to limit the minimum/maximum water temperature. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Page 9 MAINTENANCE AND SERVICE Maintenance activities In order to ensure optimal availability of the unit, a number of checks and inspections on the unit and the field wiring have to be carried out at regular intervals, preferably yearly. This maintenance should be carried out by your local agreed technician. When the unit is not going..
  • Page 10 DISASSEMBLY GUIDE (1/2) Attention! Users should never attempt disassembly on their own! Please contact a professional! “ ”...
  • Page 11 DISASSEMBLY GUIDE (2/2) Attention! Users should never attempt disassembly on their own! Please contact a professional! “ ”...
  • Page 12 DISASSEMBLY GUIDE (1/2) Attention! Users should never attempt disassembly on their own! Please contact a professional! “ ”...
  • Page 13 DISASSEMBLY GUIDE (2/2) Attention! Users should never attempt disassembly on their own! Please contact a professional! “ ”...

This manual is also suitable for:

Hn1610h nk3