Model(s):
HU161HA U33 / HN1610H NK3
Air-to-water heat pump:
YES
Water-to-water heat pump:
YES
Brine-to-water heat pump:
YES
Low-temperature heat pump:
YES
Equipped with a supplementary heater:
YES
Heat pump combination heater:
YES
Parameters shall be declared for medium-temperature application, except for low-temperature heat pumps.
For low- temperature heat pumps, parameters shall be declared for low-temperature application.
Parameters shall be declared for average climate conditions.
Low temperature application
Item
Symbol
Rated heat output (*)
P
Declared capacity for heating for part load at indoor
temperature 20 °C and outdoor temperature T j
T j = – 7 °C
P
T j = + 2 °C
P
T j = + 7 °C
P
T j = + 12 °C
P
T j = bivalent temperature
P
T j = operation limit temperature
P
For air-to-water heat pumps:
P
Tj=-15℃ (if TOL < -20℃)
Bivalent temperature
T
Cycling interval capacity for heating
P
Degradation co-efficient(**)
C
Medium temperature application
Item
Symbol
Rated heat output (*)
P
Declared capacity for heating for part load at indoor
temperature 20 °C and outdoor temperature T j
T j = – 7 °C
P
T j = + 2 °C
P
T j = + 7 °C
P
T j = + 12 °C
P
T j = bivalent temperature
P
T j = operation limit temperature
P
For air-to-water heat pumps:
P
Tj=-15℃ (if TOL < -20℃)
Bivalent temperature
T
Cycling interval capacity for heating
P
Degradation co-efficient(**)
C
Power consumption in modes other than active mode
Off mode
P
Thermostat-off mode
P
Standby mode
P
Crankcase heater mode
P
Other items
Capacity control
Sound power level, indoors/outdoors
L
L
Annual electricity consumption
Q HE, (Low Temp)
(Low Temp)
Annual electricity consumption
Q HE (Mid Temp)
(Mid Temp)
For heat pump combination heater
Declared load profile
Daily elecrictiy consumption
Qelec
Annual electricity consumption
AEC
Name : Christianna Papazahariou
Position : European Regulatory Manager
E-mail address : chris.papazahariou@lge.com Tel. 01 49 89 57 41 – 06 83 077 455
Contact details
Postal address : Paris Nord II – 117 avenue des Nations BP 59372
Villepinte – 95942 Roissy CDG Cedex
www.lg.com
(*) For heat pump space heaters and heat pump combination heaters, the rated heat output Prated is equal to the design load for heating
Pdesignh, and the rated heat output of a supplementary heater Psup is equal to the supplementary capacity for heating sup(Tj).
(**) If Cdh is not determined by measurement then the default degradation coefficient is Cdh = 0,9.
Technical parameters for heat pump space heaters and heat pump combination heaters
NO
NO
NO
NO
NO
NO
Value
Unit
13 kW
rated
11.9 kW
dh
7.0 kW
dh
4.7 kW
dh
4.8 kW
dh
13.5 kW
dh
13.5 kW
dh
x,x kW
dh
-10 ℃
biv
x,x kW
cych
0.9
dh
Value
Unit
11 kW
rated
9.6 kW
dh
5.9 kW
dh
3.7 kW
dh
4.5 kW
dh
10.8 kW
dh
10.8 kW
dh
x,x kW
dh
-10 ℃
biv
x,x kW
cych
0.9
dh
0.060 kW
OFF
0.060 kW
TO
0.060 kW
SB
0.000 kW
CK
Variable
63 dB
WA,indoor
63 dB
WA,Outdoor
8618 kWh
7424 kWh
x
x.xxx
kWh
x kWh
Item
Seasonal space heating energy efficiency
Declared coefficient of performance or primary energy ratio for part load at indoor
temperature 20 °C and outdoor temperature T j
T j = – 7 °C
T j = + 2 °C
T j = + 7 °C
T j = + 12 °C
T j = bivalent temperature
T j = operation limit temperature
For air-to-water heat pumps:
Tj=-15℃ (if TOL < -20℃)
Cycling interval efficiency
Heating water operating limit temperature
Item
Seasonal space heating energy efficiency
Declared coefficient of performance or primary energy ratio for part load at indoor
temperature 20 °C and outdoor temperature T j
T j = – 7 °C
T j = + 2 °C
T j = + 7 °C
T j = + 12 °C
T j = bivalent temperature
T j = operation limit temperature
For air-to-water heat pumps:
Tj=-15℃ (if TOL < -20℃)
For air -to-water heat pumps:
Operation limit temperature
Cycling interval efficiency
Heating water operating limit temperature
Supplementary heater
Rated heat output (*)
Type of energy input
For air-to-water heat pumps:
Rated air flow rate, outdoors (Low Temp)
For air-to-water heat pumps:
Rated air flow rate, outdoors (Mid. Temp)
For water-/brine-to-water heat pumps:
Rated brine or water flow rate,
outdoor heat exchanger
Water Pump EEI
"The benchmark for the most efficient circulators is EEI ≤ 0,20.";
Water heating energy efficiency
Daily fuel consumption
Annual fuel consumption
Symbol
Value
Unit
η
126%
S
COPd or PERd
2.40 – or %
COPd or PERd
3.30 – or %
COPd or PERd
4.20 – or %
COPd or PERd
3.80 – or %
COPd or PERd
2.10 – or %
COPd or PERd
2.10 – or %
COPd or PERd
x,xx – or %
COPcyc or PERcyc
x,xx – or %
WTOL
65 ℃
Symbol
Value
Unit
η
117%
S
COPd or PERd
2.46 – or %
COPd or PERd
3.47 – or %
COPd or PERd
3.00 – or %
COPd or PERd
3.60 – or %
COPd or PERd
2.00 – or %
COPd or PERd
2.00 – or %
COPd or PERd
x,xx – or %
TOL
-15 ℃
COPcyc or PERcyc
x,xx – or %
WTOL
65 ℃
Psup
kW
3.5
Electric
3
7044 m
/h
3
6560 m
/h
x
≤
0.20
η
x %
wh
Qfuel
x,xxx kWh
AFC
x GJ