CGS980SEMSS
GE Café 30" Free-Standing Range
Dimensions and Installation Information (in inches)
Electrical Requirements: 120v; 60Hz, 15A
Effective January 1, 1996, the National Electrical Code
requires that new construction (not existing) utilize a 4-
conductor connection to an electric range.
Receptacle Locations: Locally approved flexible service
cord or conduit must be used because terminals are
not accessible after range installation. See shaded
area in drawing for location of electrical outlet box.
Recommended outlet locations allow range to be installed
directly against wall.
Note: 30" ranges conform to U.L. requirements for 0"
spacing from adjacent walls below countertops. To reduce
possibility of scorching walls, engineering recommends a
minimum of
1-1/2" spacing to allow for possible extended, high-heat,
no-load heating element operation.
Installation information: Before installing, consult
installation instructions packed with product for current
dimensional data.
For answers to your Monogram,
GE Profile
®
GE
®
appliance questions, visit our website at
geappliances.com or call GE Answer Center
service, 800.626.2000.
with Baking Drawer
or
™
®
30"
36-1/4"
26-1/2"
46-3/4"
Recommended
area for 120V outlet
on rear wall and
area for thru the
wall connection
of pipe stub and
shut-off valve
+ _
1/4*
*Dimension from floor to top of
the cooktop. Floor to top of rear
vent trim is 37-1/4"
30
4
4
24
13
2
14-1/2
9
Recommended area
for thru the floor
connection of pipe stub
and shut-off valve
All GE ranges are equipped with
an Anti-Tip device. The installation
of this device is an important,
required step in the installation
of the range.
Specification Revised 10/10
Recommended common
area for gas outlet and
electrical outlet
2-1/2
230151