Memory Installation Guide
October 2002 (Second Edition)
Part Number 279987-002

Advertisement

Table of Contents
loading

Summary of Contents for HP ML570 - ProLiant - G2

  • Page 1 HP ProLiant ML500 Series Generation 2 Server Memory Installation Guide October 2002 (Second Edition) Part Number 279987-002...
  • Page 2 UNIX is a trademark of The Open Group in the U.S. and other countries. Hewlett-Packard Company shall not be liable for technical or editorial errors or omissions contained herein. The information in this document is provided “as is” without warranty of any kind and is subject to change without notice.
  • Page 3: Table Of Contents

    Contents About This Guide Audience Assumptions ....................... v Important Safety Information ..................... v Symbols on Equipment....................... v Rack Stability........................vii Symbols in Text........................ vii Related Documents ......................viii Getting Help........................viii Technical Support .....................viii HP Website........................ix Authorized Reseller..................... ix Reader’s Comments......................ix Chapter 1 Memory Memory Quick Start Guidelines ..................1-3...
  • Page 4 Contents Hot-Plug Mirrored Memory Technology ............... 1-19 Software ........................1-21 Configuring the Memory....................1-22 Installation, Removal, and Replacement Procedures ............ 1-23 Removing a Memory Board ................... 1-24 Removing a DIMM....................1-27 Installing a DIMM ....................1-28 Installing a Memory Board..................1-29 Chapter 2 Error Messages Index...
  • Page 5: About This Guide

    About This Guide This guide provides step-by-step installation instructions and reference information for operation, troubleshooting, and future upgrades for the memory system in HP ProLiant ML500 series generation 2 servers. Audience Assumptions This guide is for the person who installs, administers, and troubleshoots servers. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.
  • Page 6 About This Guide This symbol indicates the presence of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified personnel. WARNING: To reduce the risk of injury from electric shock hazards, do not open this enclosure. Refer all maintenance, upgrades, and servicing to qualified personnel.
  • Page 7: Rack Stability

    About This Guide Rack Stability WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: • The leveling jacks are extended to the floor. • The full weight of the rack rests on the leveling jacks. •...
  • Page 8: Related Documents

    About This Guide Related Documents • The white paper on Advanced Memory Protection on the HP website: www.compaq.com/products/servers/technology/memoryprotection.html • The hardware installation and configuration poster that ships with your server • The hardware installation and configuration labels located on the inside of the access panel of your server •...
  • Page 9: Hp Website

    About This Guide • Product model name and number • Applicable error messages • Add-on boards or hardware • Third-party hardware or software • Operating system type and revision level HP Website The HP website has information on this product as well as the latest drivers and flash ROM images.
  • Page 10: Memory

    Memory This guide explains the procedures associated with the memory system in the ProLiant ML500 series Generation 2 server. The topics include: • Memory quick start guidelines • Memory boards — Parts of the memory board — Memory board slot locations —...
  • Page 11 Memory For more information specific to Advanced Memory Protection, refer to the following resources: • The white paper on Advanced Memory Protection on the website: www.compaq.com/products/servers/technology/memoryprotection.html • The Advanced Memory Protection multimedia on the Documentation CD • The installation documentation that ships with option kits •...
  • Page 12: Memory Quick Start Guidelines

    Memory Memory Quick Start Guidelines This section gives a brief overview of memory in the ProLiant ML500 series Generation 2 servers, including: • Quick start DIMM installation • Quick start memory configuration • Quick start LED information More detailed information about each of these items can be found in following sections in this chapter.
  • Page 13: Quick Start Dimm Installation Guidelines

    Memory Use the following Table 1-1 as a quick reference for DIMM installation guidelines specific to your desired memory configuration. Table 1-1: Quick Start DIMM Installation Guidelines Advanced ECC Online Spare Memory Single-Board Hot-Plug Mirrored (Standard) Memory Mirrored Memory Memory One or two memory One or two memory Install only one...
  • Page 14: Quick Start Memory Configuration

    Memory Quick Start Memory Configuration If you plan to use online spare memory, single-board mirrored memory, or hot-plug mirrored memory, you must configure your desired memory mode through RBSU. HP also recommends testing new DIMMs. To test DIMMs and configure memory: 1.
  • Page 15: Quick Start Led Information

    Memory Quick Start LED Information Table 1-2: Memory LED States on a Properly Configured Memory Board Memory Configuration Advanced ECC Online Spare Single-Board Hot-Plug (Standard) Memory Mirrored Mirrored Memory Memory Memory Memory status Green Green Green Green DIMM 1-8, if Green Green Green...
  • Page 16: Parts Of The Memory Board

    Memory • Memory board LEDs Parts of the Memory Board Figure 1-1 and Table 1-3 identify the parts of the memory board. Figure 1-1: Parts of the memory board Table 1-3: Parts of the Memory Board Item Description DIMM slot 1, bank A (must be populated) DIMM slot 2, bank A (must be populated) DIMM slot 3, bank B DIMM slot 4, bank B...
  • Page 17: Memory Board Slot Locations

    Memory Table 1-3: Parts of the Memory Board continued Item Description Locking switch Release latches Ejector levers * When the system is configured for online spare memory, bank D on memory board 1 is the online spare bank. Memory Board Slot Locations Figure 1-2 and Table 1-4 identify the memory board slots on the system board.
  • Page 18: Memory Board Leds

    Memory Memory Board LEDs Use the following Figure 1-4 and tables to identify LEDs and icons on the memory board. Figure 1-3: Memory board LEDs and icons Table 1-5: Advanced ECC (Standard) Memory LEDs Item Description Indicator Status Memory Memory board is offline. status Green Memory board is online.
  • Page 19: Advanced Ecc (Standard) Memory Leds

    Memory Table 1-5: Advanced ECC (Standard) Memory LEDs continued Item Description Indicator Status 1-4, All LEDs Flashing amber CAUTION—memory board is in use; relock it 7, 8 immediately. Table 1-6: Online Spare Memory LEDs Item Description Indicator Status Memory Memory board is offline. status Green Memory board is online.
  • Page 20: Single-Board Mirrored Memory Leds

    Memory Table 1-7: Single-Board Mirrored Memory LEDs Item Description Indicator Status Memory Memory board is offline. status Green Memory board is online. Flashing green Memory board is busy. Amber Memory error has occurred on this memory board. Mirroring Memory board is not configured for mirrored memory. status Green Single-board mirrored memory is functioning properly.
  • Page 21: Memory Board Icons

    Memory Table 1-8: Hot-Plug Mirrored Memory LEDs continued Item Description Indicator Status Mirroring Memory board is not configured for mirrored memory. status Green Hot-plug mirrored memory is functioning properly. Amber Memory error has occurred and system has failed over to the mirrored board. “Ready to Do not remove memory board—memory board is not Hot Plug”...
  • Page 22: Advanced Ecc (Standard) Memory Technology

    Memory Advanced ECC (Standard) Memory Technology This section details the features and DIMM installation requirements for advanced ECC memory. Features Advanced ECC memory has the following advantages: • The ProLiant ML500 series Generation 2 servers support up to 32 GB of system memory.
  • Page 23: Advanced Memory Protection Options

    Memory IMPORTANT: Follow all DIMM configuration requirements carefully. If the DIMMs are not configured properly, you receive an error message during POST. Advanced Memory Protection Options The ProLiant ML500 series Generation 2 servers support three types of optional Advanced Memory Protection: •...
  • Page 24: Online Spare Memory Technology

    Memory Online Spare Memory Technology This section details the features and DIMM installation requirements for online spare memory. Features Online spare memory uses an online spare bank to provide additional memory protection. Online spare memory has the following advantages: • Online spare memory provides DIMM failover capabilities for single-bit correctable errors.
  • Page 25 Memory • Provides notification of the DIMM failure via the memory board LEDs, the front-panel internal health LED, and Insight Manager 7. This process occurs without intervention or server interruption, and enables you to replace the degraded DIMM at your convenience during a regularly scheduled shutdown.
  • Page 26: Single-Board Mirrored Memory Technology

    Memory Single-Board Mirrored Memory Technology This section details the features and DIMM installation requirements for single-board mirrored memory. Features Single-board mirrored memory uses mirrored banks on a single memory board to provide a high level of memory redundancy. Single-board mirrored memory has the following advantages: •...
  • Page 27 Memory This process occurs without intervention or server interruption, and enables you to replace the degraded DIMM at your convenience during a regularly scheduled shutdown. Multi-bit errors are detected at the bank level rather than the DIMM level, so if a multi-bit error occurs, both DIMMs in the bank must be replaced. As long as no errors have occurred on the memory board, the system periodically switches which set of banks it reads from to be sure that both sets are monitored for memory errors.
  • Page 28: Hot-Plug Mirrored Memory Technology

    Memory Hot-Plug Mirrored Memory Technology This section details the features and DIMM installation requirements for hot-plug mirrored memory. Features NOTE: Hot-plug mirrored memory mode is not available on ProLiant ML530 generation 2 servers. Hot-plug mirrored memory uses an additional memory board to provide complete memory redundancy.
  • Page 29 Memory This process occurs without intervention or server interruption, and enables you to hot-replace the failed or degraded DIMM at your convenience. Multi-bit errors are detected at the bank level rather than the DIMM level, so if a multi-bit error occurs, both DIMMs in the bank must be replaced.
  • Page 30: Software

    Memory Software The following software components of the memory system provide memory configuration and management capabilities: • ROM-Based Setup Utility (RBSU) • Insight Manager 7 IMPORTANT: The optional online spare memory, single-board mirrored memory, and hot-plug mirrored memory features do not require special software drivers and are operating system independent.
  • Page 31: Configuring The Memory

    Memory Configuring the Memory Configuring the server’s memory system requires configuring both hardware and software. To configure your memory: 1. Remove the memory board. Refer to “Removing a Memory Board” in this chapter. 2. Install the required DIMMs based on your desired memory configuration. Be sure to follow all DIMM installation requirements.
  • Page 32: Installation, Removal, And Replacement Procedures

    Memory Installation, Removal, and Replacement Procedures DIMM and memory board installation, removal, and replacement procedures can be either hot-plug or non-hot-plug procedures, depending on how the server is configured. • You cannot perform hot-plug procedures when the system is configured for: —...
  • Page 33: Removing A Memory Board

    Memory CAUTION: Be sure to power down the server when performing these procedures in a server that is not configured for hot-plug mirrored memory. Observe the following warnings when performing a hot-plug replacement procedure: WARNING: Always comply with all electrostatic and thermal guidelines to prevent bodily injury and ensure a properly functioning system when performing hot-plug operations.
  • Page 34 Memory 2. Open the hot-plug door. Refer to “Opening the Hot-Plug Door” in Chapter 3, “Installing Hardware Options,” in the setup and installation guide on the Documentation CD. Hot-replacement procedure: Determine which memory board you want to remove by locating the memory board with an amber memory status LED and one or more amber DIMM status LEDs.
  • Page 35: Removing The Memory Board

    Memory 4. Press the release latches inward firmly, disengaging the board from the server (2). Do not squeeze the latches. 5. Lift the ejector levers up (3). 6. Pull the memory board up out of the server (4). Hot-replacement procedure: While the memory board with the failed or degraded DIMM is being replaced, the system continues to read and write from the operational memory board.
  • Page 36: Removing A Dimm

    Memory Removing a DIMM To remove a DIMM: 1. Remove the memory board. Refer to “Removing a Memory Board” in this chapter. 2. Place the memory board on a level surface. 3. Open the DIMM slot latches (1) to eject the DIMM from the DIMM slot (2). Figure 1-5: Removing a DIMM HP ProLiant ML500 Series Generation 2 Server Memory Installation Guide 1-27...
  • Page 37: Installing A Dimm

    Memory Installing a DIMM To install a DIMM: 1. Remove the memory board. Refer to “Removing a Memory Board” in this chapter. 2. Observe all DIMM installation requirements for your desired memory mode. Refer to the “DIMM Installation Requirement” sections for each mode in this chapter.
  • Page 38: Installing A Memory Board

    Memory Installing a Memory Board To install a memory board: 1. Align the memory board with the memory slot and memory board guide clips. 2. Slide the memory board into the server (1) and close the ejector levers to seat the memory board firmly (2).
  • Page 39: Installing The Memory Board

    Memory 3. Engage the locking switch (3). Hot-replacement procedure: All LEDs now turn off except the memory status LED, which flashes green while data are copied from one memory board to the other. This process may take up to a minute to complete. When the copying process is complete, the other LEDs re-illuminate as described in Table 1-10.
  • Page 40: Memory Led States On A Properly Configured Memory Board

    Memory 6. Reference the LEDs on the top of the memory board to be sure that the memory is functioning properly. Table 1-10 describes what the LED states for each memory configuration when the DIMMs and memory board are installed and functioning properly.
  • Page 41: Error Messages

    Error Messages Use error messages to assist you in troubleshooting and performing basic diagnostic functions in the ProLiant ML500 series Generation 2 server. The following tables contain new and unique error messages. For a complete listing of error messages and other troubleshooting information, refer to the HP Servers Troubleshooting Guide provided on your Documentation CD or online at the website: www.compaq.com/support/techpubs/user_reference_guides...
  • Page 42: Post Error Messages

    Error Messages Table 2-1: POST Error Messages Error Code Audible Probable Source of Action Beeps Problem 207 - Invalid Memory 1 long, Unregistered DIMMs Install registered Configuration - Unsupported 1 short PC1600 ECC DDR DIMM in Board X, DIMM X. Only SDRAM DIMMs.
  • Page 43: Other Post Messages

    Error Messages Table 2-2: Other POST Messages POST message Description Advanced Memory Protection Advises that server is configured for advanced ECC memory * Mode: Advanced ECC Support Advanced Memory Protection Advises that server is configured for online spare memory* Mode: Online Spare with Advanced ECC Advanced Memory Protection Advises that server is configured for single-board mirrored...
  • Page 44: Index

    Index installation guidelines See installation guidelines standard memory 1-4 access panel labels viii, 1-2 installing 1-28 advanced ECC memory See standard quick start installation guidelines 1-3 memory removing 1-27 Advanced Memory Protection See also testing 1-22 memory type 1-13 hot-plug mirrored memory 1-19 Documentation CD viii multimedia viii, 1-2 documentation, memory-related viii, 1-2...
  • Page 45 Index locking switch disengaging 1-25 hot-add capabilities 1-14, 1-23 engaging 1-30 hot-plug mirrored memory location 1-8 DIMM installation guidelines 1-4, 1-20 error messages 2-2 features 1-19 LEDs 1-6, 1-11, 1-31 maximum configuration maximum configuration 1-19 hot-plug mirrored memory 1-19 hot-plug procedures online spare memory 1-15 guidelines 1-23 single-board mirrored memory 1-17...
  • Page 46 Index LEDs 1-6, 1-10, 1-31 maximum configuration 1-15 single-board mirrored memory option kit documentation viii, 1-2 DIMM installation guidelines 1-4, 1-18 error messages 2-2 features 1-17 LEDs 1-6, 1-11, 1-31 POST error messages 2-2 maximum configuration 1-17 poster viii, 1-2 software, memory-related 1-21 standard memory DIMM installation guidelines 1-4, 1-13...

This manual is also suitable for:

Proliant ml500 series g2

Table of Contents