Page 1
Cisco UCS C200 Server Installation and Service Guide Covers UCS C200 Server Generations M1 and M2 July 31, 2013 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883...
Page 2
Modifications to this product not authorized by Cisco could void the FCC approval and negate your authority to operate the product. The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCB’s public domain version of the UNIX operating system.
Clearing the BIOS Admin Password Using Jumper J1E4 2-19 Maintaining the Server C H A P T E R Server Monitoring and Management Tools Cisco Integrated Management Interface (CIMC) Server Configuration Utility Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Page 4
Replacing a PCIe Card 3-35 Replacement Procedure 3-36 Special Considerations for the Cisco UCS P81E Virtual Interface Card (N2XX-ACPCI01) 3-38 How to Identify Which Power Supply Model is in Your Server 3-38 Installing Multiple PCIe Cards and Resolving Limited Resources...
Page 5
How To Launch Option ROM-Based Controller Utilities Restoring RAID Configuration After Replacing a RAID Controller For More Information Installation for Cisco UCS Integration A P P E N D I X Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Page 6
Contents Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
This preface describes the audience, organization, and conventions of the Cisco UCS C200 Server Installation and Service Guide. It also provides information on how to obtain related documentation. This guide covers UCS C200 Server Generations M1 and M2. Differences between the generations are noted in text.
Page 8
Tämä varoitusmerkki merkitsee vaaraa. Tilanne voi aiheuttaa ruumiillisia vammoja. Ennen kuin käsittelet laitteistoa, huomioi sähköpiirien käsittelemiseen liittyvät riskit ja tutustu onnettomuuksien yleisiin ehkäisytapoihin. Turvallisuusvaroitusten käännökset löytyvät laitteen mukana toimitettujen käännettyjen turvallisuusvaroitusten joukosta varoitusten lopussa näkyvien lausuntonumeroiden avulla. SÄILYTÄ NÄMÄ OHJEET Cisco UCS C200 Server Installation and Service Guide viii OL-20732-02...
Page 9
Utilize o número da instrução fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham este dispositivo. GUARDE ESTAS INSTRUÇÕES Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Page 10
Använd det nummer som finns i slutet av varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna anordning. SPARA DESSA ANVISNINGAR Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Page 11
Brug erklæringsnummeret efter hver advarsel for at finde oversættelsen i de oversatte advarsler, der fulgte med denne enhed. GEM DISSE ANVISNINGER Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Page 12
Preface Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Obtaining Documentation and Submitting a Service Request For information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly What’s New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at: http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html...
Page 14
Preface Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Page 15
C H A P T E R Overview The Cisco UCS C200 Server, which is a part of the Cisco UCS C-Series Rack-Mount server family, is designed to operate in a wide range of data center environments, including those environments that use the Cisco Unified Computing System, Cisco Nexus family products, and discrete Ethernet and Fibre Channel switches from Cisco and third parties.
1. See the following caution. 2. See the following caution. Do not use the Reset button. This button is for development debugging only. This button will reset Caution memory and CPU settings to the defaults. Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Page 17
Power supply (up to two) Video connector (DB15 VGA) 10/100 Ethernet management port (RJ-45) 10/100/1000 Gigabit Ethernet ports (two) USB 2.0 connectors (two) Low-profile PCIe card slot Serial connector (DB9) Standard-profile PCIe card slot Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Page 18
Chapter 1 Overview The Cisco UCS C200 server has the following components and features. Differences between the Large Form Factor (LFF) version of the server (PID R200-1120402W) and the Small Form Factor (SFF) version of the server (PID UCS-BSE-SFF-C200) are noted.
Page 19
4. SATA = serial advanced technology attachment 5. VGA = video graphics array 6. USB = universal serial bus 7. KVM = keyboard, video, mouse 8. PCIe = peripheral component interconnect express Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Page 20
Chapter 1 Overview 9. RAID = redundant array of independent disks Appendix A, “Technical Specifications” for more physical, environmental, and power details. Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Statement 1071 Only trained and qualified personnel must be allowed to install, replace, or service this equipment. Warning Statement 1030 Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Shipping Box Contents Reset Console PSU MEM CPU UCS C200 Server Documentation Drivers and Utilities disc KVM cable Power cord (up to two) C200 SFF server only: Two SAS cables (R200-SASCBL) Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Avoid UPS types that use ferroresonant technology. These UPS types can become unstable with systems Caution such as the Cisco UCS, which can have substantial current draw fluctuations from fluctuating data traffic patterns. Cisco UCS C200 Server Installation and Service Guide...
The minimum vertical rack space per server must be one rack unit (RU), equal to 1.75 inches (4.45 cm). The distance between the front and rear rack posts must be as follows to fit the Cisco slide rails: • –...
If your rack has #10-32 rack-post holes, align the mounting pegs with the holes and then compress the spring-loaded pegs to expose the #10-32 inner peg. Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Page 26
Pegs in standard (uncompressed) position Pegs compressed to expose 10-32 inner peg Pull the inner slide rails on each assembly out toward the rack front until they hit the internal stops and lock in place. Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Page 27
Push the plastic installation release clip on each mounting bracket toward the server rear (see item 4 in Figure 2-4), and then continue pushing the server into the rack until its front flanges touch the rack posts. Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Page 28
Two-hole slotted bracket on end of CMA length-adjustment slider Rear of left slide rail assembly Outermost CMA attachment clip Step 5 Continue with the “Connecting and Powering On the Server (Standalone Mode)” section on page 2-9. Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Cisco Integrated Management Interface (CIMC). If you want to use the 10/100 management ports or a Cisco network adapter card port to access the CIMC, you must first connect to the server and change the NIC mode as described in Step 3 of the following procedure.
Page 30
Shared LOM (default)—The two 1Gb Ethernet ports are used to access the CIMC. This is the – factory default setting, along with Active-active NIC redundancy and DHCP enabled. Cisco Card—The ports on an installed Cisco network adapter card are used to access the CIMC. – You have to select a NIC redundancy and IP setting.
Page 31
The links to these documents are in the C-Series documentation roadmap: http://www.cisco.com/go/unifiedcomputing/c-series-doc To install or replace hardware components, see the “Maintaining the Server” section on page 3-1. Cisco UCS C200 Server Installation and Service Guide 2-11 OL-20732-02...
Shared LOM (default)—The two 1Gb Ethernet ports are used to access the CIMC. This is the factory default setting, along with Active-active NIC redundancy and DHCP enabled. Cisco Card—The ports on an installed Cisco network adapter card are used to access the CIMC. You •...
Your system firmware must be at minimum level 1.2 to use the Cisco Host Upgrade Utility. If Note your firmware is prior to level 1.2, you must use the methods below to update the BIOS and CIMC firmware individually.
Step 6 Follow the instructions on the Exit menu screen to save your changes and exit the setup utility (or Press F10). You can exit without saving changes by pressing Esc. Cisco UCS C200 Server Installation and Service Guide 2-14 OL-20732-02...
Replace the top cover, replace the server in the rack, replace power cords and any other cables, then Step 15 power on the server by pressing the Power button. Cisco UCS C200 Server Installation and Service Guide 2-16 OL-20732-02...
Replace the top cover, replace the server in the rack, replace power cords and any other cables, then Step 11 power on the server by pressing the Power button. Cisco UCS C200 Server Installation and Service Guide 2-17 OL-20732-02...
Replace the top cover, replace the server in the rack, replace power cords and any other cables, then Step 11 power on the server by pressing the Power button. Cisco UCS C200 Server Installation and Service Guide 2-18 OL-20732-02...
If you do not remove the jumper, the password is cleared every time that you power-cycle the server. Replace top cover, replace the server in the rack, replace power cords and any other cables, then power Step 11 on the server by pressing the Power button. Cisco UCS C200 Server Installation and Service Guide 2-19 OL-20732-02...
Page 40
Chapter 2 Installing the Server System BIOS and CIMC Firmware Cisco UCS C200 Server Installation and Service Guide 2-20 OL-20732-02...
Configuring some RAID configurations • Installing operating systems This utility is shipped with new servers on CD. You can also download the ISO from Cisco.com. See the user documentation for this utility at the following URL: http://www.cisco.com/en/US/docs/unified_computing/ucs/sw/ucsscu/user/guide/20/SCUUG20.html Cisco UCS C200 Server Installation and Service Guide...
CPU fault LED Hard drive fault LED Network activity LED Hard drive activity LED System fault LED Power supply fault LED Locator LED/Locator button Memory fault LED 10 Power status LED/Power button Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Page 43
Off—All power supplies are operating properly. • Amber—At least one power supply has failed. • Memory fault Off—All DIMMs are operating properly. • Amber—At least one memory bank has a failed DIMM. • Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Figure 3-3 Rear Panel LEDs Power supply status LED 10/100 Ethernet link status LED Rear Locator LED 10/100/1000 Gigabit Ethernet speed LED 10/100 Ethernet speed LED 10/100/1000 Gigabit Ethernet link status LED Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Page 45
Link status amber + speed solid green—A half-duplex, 100-Mbps • link is present. Link status off + speed blinking green—A full-duplex, • 10-Mbps link is present. Link status amber + speed blinking green—A full-duplex, • 100-Mbps link is present. Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Page 46
Link status off + speed blinking green—A full-duplex, 10-Mbps link is present. Link status green + speed blinking green—A full-duplex, • 100-Mbps link is present. Link status amber + speed blinking green—A full-duplex, • 1000-Mbps link is present. Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
• Configuration Guide or the Cisco UCS C-Series Rack-Mount Server CLI Configuration Guide. Use the Power button on the server front panel. To use the Power button, follow these steps: • Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
2-7), and then continue pushing the server in evenly until its front flanges touch the rack posts. Tighten the thumbscrews on each flange to secure the server to the rack posts. Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Use a Number 2 Phillips head screwdriver to remove the two screws that secure the top cover (Generation M1 only). The UCS C200 Generation M2 server does not have cover screws. Note Press down on the release button and use the nonslip pad to push the cover toward the rear about one inch, until you feel it stop sliding.
Removing and Replacing the Server Top Cover, page 3-9. Figure 3-5 Removing the Front Cover of the Server Front cover, with 4 screws on the upper surface and 3 screws on each side Cisco UCS C200 Server Installation and Service Guide 3-10 OL-20732-02...
CPUs and heatsinks (up to two) 10 Socket for mezzanine card 11 Power supplies (up to two, accessible through Motherboard CMOS battery rear bays) PCIe card connector on riser card (with standard-profile slot) Cisco UCS C200 Server Installation and Service Guide 3-11 OL-20732-02...
Page 52
CPUs and heatsinks (up to two) Motherboard CMOS battery 12 Power supplies (up to two, accessible through rear bays) 13 Internal USB port on motherboard (active in server Generation M2 only) Cisco UCS C200 Server Installation and Service Guide 3-12 OL-20732-02...
See Figure 3-9. Replace the front cover as described in the “Removing and Replacing the Server Front Cover (Small Form Factor Only)” section on page Cisco UCS C200 Server Installation and Service Guide 3-14 OL-20732-02...
Page 55
Power button. Figure 3-8 Removing and Replacing a Front Panel Control Module or DVD Module Securing screw Securing pegs on chassis (three) Keyed holes on module (three) Cisco UCS C200 Server Installation and Service Guide 3-15 OL-20732-02...
Page 56
Front VGA Front VGA SATA CONN SATA CONN Fans Fans Front panel control module module Securing screw (one on each end) Fan tray connector Fan tray with battery unit bracket Cisco UCS C200 Server Installation and Service Guide 3-16 OL-20732-02...
Note Cisco recommends following the industry-standard practice of using drives of the same capacity when configuring RAID volumes. If you use drives of different capacities, the usable portion of the smallest drive will be used on all drives of the RAID volume.
Page 58
HDD_02 HDD_03 HDD_04 Figure 3-11 Removing and Replacing Hard Drives (Large Form Factor) Reset Console PSU MEM CPU Release button Hard drive sled, bottom view Ejector lever Securing screws (four) Cisco UCS C200 Server Installation and Service Guide 3-18 OL-20732-02...
Page 59
Drive Numbering and Physical Orientation, Facing Server Front (Small Form Factor) HDD_01 HDD_02 HDD_03 HDD_04 HDD_05 HDD_06 HDD_07 HDD_08 Figure 3-13 Removing and Replacing Hard Drives (Small Form Factor) Ejector lever Securing screws (four) Release button Cisco UCS C200 Server Installation and Service Guide 3-19 OL-20732-02...
Replace the power cord to the new power supply. Press the Power button to return the server to main power mode. Figure 3-14 Removing and Replacing a Power Supply PSU2 PSU1 PSU2 PSU1 Release lever Power supply handle Cisco UCS C200 Server Installation and Service Guide 3-20 OL-20732-02...
Replace the cable cover and the top cover. Replace the server in the rack, replace power cords and any other cables, and then power on the server by pressing the Power button. Cisco UCS C200 Server Installation and Service Guide 3-21 OL-20732-02...
Page 62
Maintaining the Server Installing or Replacing Components Figure 3-15 Removing and Replacing a Fan Tray Securing screw (one on each end) Fan tray connector Fan tray with battery unit bracket Cisco UCS C200 Server Installation and Service Guide 3-22 OL-20732-02...
Bank–1, while A2, B2, C2 belong to Bank–2. Note that each slot within Bank 1 is blue, while each slot within Bank 2 is black. See Figure 3-16. Cisco UCS C200 Server Installation and Service Guide 3-23 OL-20732-02...
Page 64
Note that this causes the system BIOS to default to standard-voltage operation (Performance Mode). See Low-Voltage DIMM Considerations (Generation M2 Only), page 3-25. Low voltage DIMMs are supported in Generation M2 servers only. Note Cisco UCS C200 Server Installation and Service Guide 3-24 OL-20732-02...
Page 65
DIMMs, memory mirroring is automatically disabled. If memory mirroring is used, the DRAM size is reduced by 50 percent for reasons of reliability. • Memory sparing is not supported. Cisco UCS C200 Server Installation and Service Guide 3-25 OL-20732-02...
Replace the air baffle and the top cover. Replace the server in the rack, replace power cords and any other cables, and then power on the server by pressing the Power button. Cisco UCS C200 Server Installation and Service Guide 3-26 OL-20732-02...
Page 67
Maintaining the Server Installing or Replacing Components Figure 3-17 Removing and Replacing Memory Modules DIMM slots (twelve) Alignment key in DIMM slot DIMM slot ejector lever (two on each slot) Cisco UCS C200 Server Installation and Service Guide 3-27 OL-20732-02...
Additional CPU-Related Parts To Order With RMA Replacement Motherboards When a return material authorization (RMA) of the motherboard or CPU is done on a Cisco UCS C-series server, there are additional parts that might not be included with the CPU or motherboard spare bill of materials (BOM).
Replace the air baffle and the top cover. Replace the server in the rack, replace power cords and any other cables, and then power on the server by pressing the Power button. Cisco UCS C200 Server Installation and Service Guide 3-29 OL-20732-02...
Page 70
Maintaining the Server Installing or Replacing Components Figure 3-18 Removing and Replacing CPUs and Heatsinks Captive heatsink screws (two per CPU) CPU socket alignment keys CPU cover plate CPU socket latch Cisco UCS C200 Server Installation and Service Guide 3-30 OL-20732-02...
Ensure that the retaining clip clicks over the top of the battery. Replace the top cover. Replace the server in the rack, replace power cords and any other cables, and then power on the server by pressing the Power button. Cisco UCS C200 Server Installation and Service Guide 3-31 OL-20732-02...
TPM to press the connector into the socket. Replace the securing screw that holds the TPM to the motherboard standoff. Replace the PCIe riser card assembly. Cisco UCS C200 Server Installation and Service Guide 3-32 OL-20732-02...
Page 73
You can reboot the server by pressing the Power button on the server; by selecting Macros > Ctrl-Alt-Del on the Cisco KVM Console window menu bar; or by selecting Power Cycle Server on the Server Summary tab of the CIMC GUI.
Replace the screw that secures the assembly to the chassis. Replace the top cover. Replace the server in the rack, replace power cords and any other cables, and then power on the server by pressing the Power button. Cisco UCS C200 Server Installation and Service Guide 3-34 OL-20732-02...
How to Identify Which Power Supply Model is in Your Server, page 3-38 • Installing Multiple PCIe Cards and Resolving Limited Resources, page 3-39 If you are installing a Cisco UCS P81E Virtual Interface Card (N2XX-ACPCI01), there are prerequisite Note considerations. See...
Power button. Step 4 If the card that you replaced was a RAID controller card, see Restoring RAID Configuration After Replacing a RAID Controller, page C-6. Cisco UCS C200 Server Installation and Service Guide 3-36 OL-20732-02...
Page 77
PCIe Slot 6 Figure 3-23 Removing and Replacing a PCIe Card Riser card assembly removed from chassis PCIe card rear plate PCIe socket on riser card PCIe card retaining latch Cisco UCS C200 Server Installation and Service Guide 3-37 OL-20732-02...
This server supports installation of one of these cards. • This card is supported only in PCIe slot 6 of this server. • This card must be installed in PCIe slot 6 to use the Cisco Card NIC mode (see Figure 3-22 on Note page 3-37).
ROMs for the onboard NICs to be booted from are enabled in the BIOS Setup Utility. Disable other option ROMs that are not needed to create sufficient memory space for the onboard NICs. Cisco UCS C200 Server Installation and Service Guide 3-39...
Page 80
Physically remove any unused PCIe cards. If the system has one or more Cisco virtual interface cards (VICs) installed, disable the PXE boot on the VICs that are not required for the system boot configuration by using the Network Adapters page in the CIMC WebUI to free up some 16-bit I/O resources.
Replacing an LSIiBBU08 BBU, page 3-43 • Replacing an LSIiBBU06 BBU This BBU is supported by Cisco for use with the following RAID controller cards: LSI MegaRAID 9260-4i (Cisco product ID R200-PL004, LSI 6G MegaRAID 9260-4i • card w/512MB write cache) LSI MegaRAID 9280-4i4e (Cisco product ID UCSC-RAID-C-4i4e, LSI 9280-4i4e) •...
Page 82
Be careful to align the arrow-mark on the cable connector with the arrow-mark on the socket to avoid Note damaging the connector pins. Figure 3-24 Removing and Replacing an LSIiBBU06 BBU BBU bracket on fan tray BBU (connector J2 is on the underside) Securing screws (three) Cisco UCS C200 Server Installation and Service Guide 3-42 OL-20732-02...
Maintaining the Server Installing or Replacing Components Replacing an LSIiBBU08 BBU This BBU is supported by Cisco for use with the following RAID controller cards: LSI MegaRAID 9260-4i (Cisco product ID R200-PL004, LSI 6G MegaRAID 9260-4i • card w/512MB write cache) LSI MegaRAID 9280-4i4e (Cisco product ID UCSC-RAID-C-4i4e, LSI 9280-4i4e) •...
Page 84
The LSIiBBU08 BBU requires minimum LSI MegaRAID card firmware 2.120.133.1322 or later to be Note recognized. You can use the Cisco Host Upgrade Utility to upgrade your LSI MegaRAID card firmware. Obtain the Cisco Host Upgrade Utility 1.4.1 or later package (including drivers) by navigating from the Cisco.com software download site: http://www.cisco.com/cisco/software/navigator.html...
Page 85
Maintaining the Server Installing or Replacing Components Figure 3-27 Removing and Replacing an LSIiBBU06 BBU BBU bracket on fan tray BBU (connector J2 is on the underside) Securing screws (two) Cisco UCS C200 Server Installation and Service Guide 3-45 OL-20732-02...
Reconnect the cable harness to the connector on the top of the mezzanine card. Replace the top cover. Replace the server in the rack, replace power cords and any other cables, and then power on the server by pressing the Power button. Cisco UCS C200 Server Installation and Service Guide 3-46 OL-20732-02...
Page 87
Chapter 3 Maintaining the Server Installing or Replacing Components Figure 3-28 Removing and Replacing a Mezzanine Card Mezzanine card retaining posts (three) Mezzanine card Cisco UCS C200 Server Installation and Service Guide 3-47 OL-20732-02...
Page 88
Chapter 3 Maintaining the Server Installing or Replacing Components Cisco UCS C200 Server Installation and Service Guide 3-48 OL-20732-02...
A P P E N D I X Technical Specifications This appendix lists the technical specifications for the Cisco UCS C200 server and includes the following sections: Physical Specifications, page A-1 • Environmental Specifications, page A-2 • Power Specifications, page A-2 •...
Power supply output voltage Main power: 12 VDC Standby power: 5 VDC You can get more specific power information for your exact server configuration by using the Cisco UCS Power Calculator: http://www.cisco.com/assets/cdc_content_elements/flash/dataCenter/cisco_ucs_power_calculator/ Cisco UCS C200 Server Installation and Service Guide...
USB ports for a keyboard and mouse. With this cable, you can create a direct connection to the operating system and the BIOS running on the server. This server supports the following Cisco components and part numbers. Supported Components...
Power Cord, 250 VAC 10 A MP232 Plug Switzerland CAB-9K10A-UK Figure B-10 Power Cord, 250 VAC 10 A BS1363 Plug (13 A fuse) United Kingdom CAB-AC-250V/13A Figure B-11 Power Cord, 250 VAC 13 A IEC60320 Plug North America Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Length: 8.2 ft Plug: EL 219 (IRAM 2073) Connector: EL 701 (IEC60320/C13) Figure B-3 CAB-9K10A-AU Cordset rating: 10 A, 250 V/500V Length: 2500mm Connector: Plug: EL 701C EL 206 (IEC 60320/C15) A.S. 3112-2000) Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Page 94
Cordset rating: 10A/16 A, 250 V Length: 8 ft 2 in. (2.5 m) Plug: M2511 Connector: VSCC15 Figure B-6 SFS-250V-10A-ID Cordset rating 16A, 250V Plug: (2500mm) EL 208 Connector: EL 701 Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Page 95
Length: 8 ft 2 in. (2.5 m) Plug: Connector I/3G C15M (CEI 23-16) (EN60320/C15 ) Figure B-9 CAB-9K10A-SW Cordset rating: 10 A, 250 V Length: 8 ft. 2 in (2.5 m) Plug: MP232-R Connector: IEC 60320 C15 Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Page 96
Cordset rating 13A, 250V (6.6 feet) (79±2m) Connector: Plug: EL 701 EL312MoldedTwistlock (IEC60320/C13) (NEMA L6-20) Figure B-12 CAB-N5K6A-NA Cordset rating: 10 A, 250 V Length: 8.2 ft Plug: NEMA 6-15P Connector: IEC60320/C13 Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Page 97
Supported Power Cords and Plugs Figure B-13 CAB-9K12A-NA Cordset rating 13A, 125V (8.2 feet) (2.5m) Plug: Connector: NEMA 5-15P IEC60320/C15 Figure B-14 CAB-C13-C14-JMPR, Jumper Power Cord Cordset rating 10A, 250V (686mm) Connector: Plug: HS10S SS10A Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
Page 98
Appendix B Cable and Power Cord Specifications Supported Power Cords and Plugs Cisco UCS C200 Server Installation and Service Guide OL-20732-02...
• For More Information, page C-7 • Supported RAID Controllers and Required Cables The Cisco UCS C200 Large Form-Factor (LFF) and C200 Small Form-Factor (SFF) server models support the RAID controller options and cable requirements shown in Table C-1 Table C-2.
1. The integrated ICH10R controller must be enabled in the BIOS. This controller is not compatible for use with VMWare ESX/ESXi Server software in any generation or version of the Cisco UCS C200 server. 2. You can mix SAS and SATA drives when using a 1068E-based controller. However, you cannot mix SAS and SATA drives within a volume.
C-1. The blue line indicates the recommended cable routing path from the backplane to the possible controller locations. Note The Cisco UCS C200 SFF server is shown, with an eight-drive backplane. The LFF server has a four-drive backplane. Figure C-1...
Cisco UCS C200 SFF Server Cabling The cable connections required for each type of controller are as follows: Two SAS cables (R200-SASCBL) are shipped with the Cisco UCS C200 SFF server (but not with the Note LFF version of the server). You can order a set of two spare SAS cables (Cisco PID UCSC-CBL-I2F1).
On the Main page of the BIOS Setup utility, set Quiet Boot to Disabled. This allows non-default Step 3 messages, prompts, and POST messages to display during bootup instead of the Cisco logo screen. Press F10 to save your changes and exit the utility.
Note you in setting up some RAID configurations for your drives. This utility is shipped with new servers on CD. You can also download the ISO from Cisco.com. See the user documentation for this utility at the following URL: http://www.cisco.com/en/US/docs/unified_computing/ucs/sw/ucsscu/user/guide/20/SCUUG20.html Restoring RAID Configuration After Replacing a RAID Controller When you replace a RAID controller, the RAID configuration that is stored in the controller is lost.
The Cisco UCS integration instructions have been moved to the integration guides found here: Cisco UCS C-Series Server Integration with UCS Manager Guides Refer to the guide that is for the version of Cisco UCS Manager that you are using. Cisco UCS C200 Server Installation and Service Guide...