Installation Manual of Room Air Conditioner

1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)
Accessory parts
No.
Accessory parts
1
Remote controller
2
R-03 dry battery
3
Mounting plate
4
Drain hose
5
4X25
Plastic cap
Screw
6
Drain-elbow
7
Cushion
No.0010515194
Necessary Tools for Installation
5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife
Drawing for the installation of indoor and outdoor units
Number
of
articles
1
2
Optional parts for piping
1
Mark
Parts name
A
Non-adhesive tape
1
Adhesive tape
B
C
Saddle(L.S) with screws
4
Connecting electric cable
D
for indoor and outdoor
Drain hose
E
1
F
Heating insulating material
G
Piping hole cover
4
Read this manual before installation
Explain sufficiently the operating means to the user
according to this manual.
9.Nipper
10.Gas leakage detector or
soap-and-water solution
11.Measuring tape
Arrangement of piping directions
Rear left
Rear
Left
right
Right
Below
The marks from
A
to
G
The distance between the indoor unit and the floor should be
more than 2m.
12.Reamer
Attention must be paid to
the rising up of drain hose
in the figure are the parts numbers.
D
E

Advertisement

Table of Contents
loading

Summary of Contents for Haier 10515194

  • Page 1: Installation Manual Of Room Air Conditioner

    Optional parts for piping Mounting plate Drain hose 4X25 Plastic cap Screw Drain-elbow Cushion No.0010515194 Read this manual before installation Explain sufficiently the operating means to the user according to this manual. 5.Torque wrench(17mm,22mm,26mm) 6.Pipe cutter 7.Flaring tool 8.Knife Drawing for the installation of indoor and outdoor units...
  • Page 2: Selection Of Installation Place

    Floor fixing dimensions of the outdoor unit (Unit:mm) Fixing of outdoor unit Selection of Installation Place Indoor Unit Place, robust not causing vibration, where the body can be supported sufficiently. Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the unit are not disturbed.
  • Page 3: Indoor Unit

    1.Fitting of the Mounting Plate and Positioning of the wall Hole When the mounting plate is first fixed 1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail. 2.
  • Page 4: Installation Of The Indoor Unit

    3.Installation of the Indoor Unit Drawing of pipe Rear piping Draw pipes and the drain hose, then fasten them with the adhesive tape Left Left-rear piping In case of left side piping, cut away, with a nipper, the lid for left piping. In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear piping which is marked on heat insulation materials.
  • Page 5: When Connecting The Cable Before Installing The Indoor Unit

    When connecting the cable after installing the indoor unit 1. Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed. 2. Pull out the cable on the front side, and connect the cable making a loop. When connecting the cable before installing the indoor unit Insert the cable from the back side of the unit, then pull it out on the front side.
  • Page 6: Installation Of Outdoor Unit

    1.Installation of Outdoor Unit Drawing for the installation of indoor and outdoor units Install according to 2.Connection of pipes To bend a pipe, give the roundness as large as possible not to crush the pipe. Connecting the pipe of gas side first makes working easier. The max vertical distance between the indoor unit and the outdoor unit is 5 m.
  • Page 7: Purging Method

    Outdoor unit 5.Purging Method: Push the air out of the indoor unit and piping as followes: (1) Remove the valve cap on 2-way valve in outdoor unit. (2) Loosen by 1/2 turn the flare nut of gas pipe, which is conneted to 3-way valve.
  • Page 8: Power Source Installation

    1.Power Source Installation The power source must be exclusively used for air conditioner. (Over I0A) In the case of installing an air conditioner in a moist place, please install an earth leakage breaker. For installation in other places, use a circuit breaker as far as possible.