Page 2
Information in this document is subject to change without notice. Reproduction of this document in any manner whatsoever, without the written permission of the D-Link Corporation, is strictly forbidden. Trademarks used in this text: D-Link and the D-Link logo are trademarks of the D-Link Corporation; Microsoft and Windows are registered trademarks of the Microsoft Corporation.
The DXS-3600-32S Web UI Reference Guide contains detailed information about the Web User Interface of the switch in this series. This manual is intended for advanced level users that are familiar with network management concepts and terminology. For all practical reasons the DXS-3600-32S will simply be referred to as the switch throughout this manual.
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Safety Cautions To greatly reduce the risk of physical injury, electrical shock, fire, and damage to equipment, observe the following precautions. Observe and follow service markings. • Do not attempt to service any product, except when it is explained in the system’s documentation.
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide • 115V/60Hz is used mostly in North and South America as well as Far Eastern countries like as South Korea and Taiwan • 100V/50Hz is used mostly in Eastern Japan and 100V/60Hz in Western Japan •...
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Web-based Switch Configuration Management Options Connecting using the Web User Interface Management Options This switch provides multiple access platforms that can be used to configure, manage and monitor networking features available on this switch. Currently there are three management platforms available and they are described below.
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Figure 2-2 Enter Network Password window As there is no default User name or Password, click OK to proceed. This will open the Web-based User Interface. The switch management features available in the Web-based manager are explained below.
Page 9
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide On this page we will find three main areas to observe. Area Number Function AREA 1 This area displays graphical, real-time images of some of the hardware features run- ning on this switch. Some of the features that can be monitored here are the Device Information, Temperature, CPU Usage, System Log, Fan Status, Memory Usage, and Network Traffic Utilization.
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Switch Status Device Information Temperature Status CPU Status System Log Entries Fan Status Flash, SD Card, and Memory Status After clicking on the Switch Status link, found in the menu, the following page will be displayed:...
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Device Information In the Device Information section, the user can view a list of basic information regarding the switch. In the Device Information section, the following display parameters are available: Parameter...
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Temperature Status In the Temperature section, the user can view a real-time display of the switch’s internal temperature. The temperature of the switch is mainly influenced by two factors: (1) the enviroment, and (2) the internal air-flow of the switch. In the Hardware Installation Guide, there are some guidelines the can assist the user with the installation of this switch in a temperature friendly environment.
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide CPU Status In the CPU section, the user can view a real-time display of the switch’s CPU usage. There are a number of factors that can influance a depleted CPU usage. One of those factors are network broadcasts. In the CLI Reference Guide there is an abundance of features that can be enabled to prevent this problem from occuring.
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide System Log Entries In the System Log section, the user can view a list of System log entries, generated by the switch, when certain events have occured. In the System Log section, the following display parameters are available:...
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Fan Status In the Fan section, the user can view a real-time display of the switch’s fan(s) status. A maximum of 3 fans can be installed in this switch. In this real-time graphic, we observe the status and speed of the three fans installed.
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Flash, SD Card, and Memory Status In this section, the user can view a real-time graphic that represents the memory usage for the Flash, SD Card, and RAM Memory. In this section, the following display parameters are available:...
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Traffic Monitoring Traffic Monitoring by Direction Traffic Monitoring by Type Traffic Monitoring by Size Traffic Monitoring by Error After clicking on the Traffic Monitoring link, found in the menu, the following pages will be displayed.
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Traffic Monitoring by Type This page can be used to monitor traffic, per-port, of a certain type. After selecting a Port number and then selecting the Type option, from the drop-down menu, click the Apply button to...
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Traffic Monitoring by Size This page can be used to monitor traffic, per-port, of a certain packet size. After selecting a Port number and then selecting the Size option, from the drop-down menu, click the Apply button to...
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Traffic Monitoring by Error This page can be used to monitor traffic, per-port, of a certain error type and direction. After selecting a Port number and then selecting the Error option, from the drop-down menu, click the Apply button to...
Also from time to time, D-Link provides new features that can only be acquired with a new firmware update. Keeping a copy of the configuration file ensures the convenience of not having to reconfigure the switch if it needs to be replaced.
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide The following parameters can be configured in this section: Parameter Description Destination File Enter the location and name of the Destination File. Source File Enter the location and name of the Source File or click the Browse button to navigate to the firmware file for the download.
Page 24
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide The following parameters can be configured in this section: Parameter Description Source File Enter the location and name of the Source File for the upload. Click the Upload button to initiate the upload.
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Appendix A - Password Recovery Procedure This section describes the procedure for resetting passwords on the D-Link DXS-3600-32S switch. Authenticating any user who tries to access networks is necessary and important. The basic authentication method used to accept qualified users is through a local login, utilizing a Username and Password.
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Appendix B - System Log Entries The following table lists all possible entries and their corresponding meanings that will appear in the System Log of this Switch. Category Log Description Severity...
Page 29
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: Port link down. Informational Log Message: Port <portNum> link down Parameters description: portNum: 1.Interger value;2.Represent the logic port number of the device. 802.1X Event description: 802.1X Authentication failure.
Page 30
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: 802.1p default priority assigned from RADIUS server Informational after RADIUS client is authenticated by RADIUS server successfully. This 802.1p default priority will be assigned to the port.
Page 31
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: Conflict LLDP-MED device type detected Notice Log Message: Conflict LLDP-MED device type detected ( on port < portNum >, chassis id: < chassisType>, <chassisID>, port id: < portType>, <portID>, device class: <deviceClass>)
Page 32
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: BGP FSM with Peer has gone to the successfully Informational established state. Log Message: [BGP(1):] BGP connection is successfully established (Peer:<ipaddr>). Parameters description: ipaddr: IP address of BGP peer.
Page 33
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: The number of bgp prefix received from this neighbor Warning reaches the threshold. Log Message: [BGP(8):] The number of prefix received reaches <num>, max <limit> (Peer < ipaddr >).
Page 34
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: One OSPF neighbor state changed from Loading to Full. Notice Log Message: OSPF nbr <nbr-id> on interface <intf-name> changed state from Loading to Full Parameters description: intf-name: Name of OSPF interface.
Page 35
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: One virtual router state becomes Init. Informational Log Message: VR <vr-id> at interface <intf-name> switch to Init Parameters description: vr-id: VRRP virtual router ID.
Page 36
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: A virtual MAC address is adding into switch L3 table. Notice Log Message: Added a virtual IP <vrrp-ip-addr> MAC <vrrp-mac-addr> into L3 table Parameters description:...
Page 37
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: Failed when adding a virtual MAC into switch L3 table. Error The box where the MAC is learned from is invalid. Log Message: Failed to add virtual IP <vrrp-ip-addr> MAC <vrrp-mac-addr>...
Page 38
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Port Security Event description: Address full on a port Warning Log Message: Port security violation (MAC address: < macaddr > on < interface-id >) Parameters description: macaddr: The violation MAC address.
Page 39
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: Successful Enable Admin authenticated by AAA local or Informational none or server. Log Message: Successful Enable Admin through <Console | Telnet | Web(SSL) | SSH> from <ipaddr > authenticated by AAA <local | none | server <ipaddr>>...
Page 41
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: Spanning Tree port status changed Notice Log Message: Spanning Tree port status changed [( [Instance:<InstanceID> ], port:< portNum>)] <old_status> -> <new_status> Parameters description: InstanceID: Instance ID.
Page 42
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Port Event description: port linkup Informational Log Message: Port <port> link up, <nway> Parameters description: port: Represents the logical port number. nway: Represents the speed and duplex of link.
Page 43
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Category Log Description Severity Note Event description: Temperature sensor enters alarm state. Warning Log Message: [Uint <unitID>] Temperature sensor <sensorID> enters alarm state (current temperature: <temperature>) Parameters description: unitID: The unit ID.
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Appendix C - Trap Entries This table lists the trap logs found on the Switch. Category Trap Name Description UP/Download agentFirmwareUpgrade This trap is sent when the process of 1.3.6.1.4.1.171.12.1.7.2.0.7 upgrading the firmware via SNMP has finished.
Page 45
DXS-3600-32S 10GbE Layer 2/3 Switch Web UI Reference Guide Category Trap Name Description Start Trap coldStart A coldStart trap signifies that the 1.3.6.1.6.3.1.1.5.1 SNMPv2 entity, acting in an agent role, is reinitializing itself and that its configuration may have been altered.