5-2.
Flange Back Adjustment (2)
Perform this adjustment after performing "Flange Back Adjust-
ment (1)".
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified value
Note 1: Perform the adjustment with the lens in horizontal state.
Note 2: Check that the data of page: 0, address: 10 is "00".
Note 3: Check that the data of page: 6, address: 02 is "00". If
not, select page: 6, address: 01, set data: 00, and press
PAUSE button.
Note 4: Don't touch the zoom lever during adjustment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) COLOR SLOW S (Menu setting) ................................... OFF
Preparations before adjustments:
1) Set the zoom lens to the TELE end and expose a subject that is
more than 500 m away.
(subjects with clear contrast such as building, etc.)
(Nearby subjects less than 500 m away should not be in the
screen)
Adjusting method:
Order Page Address Data
1
0
2
6
3
4
5
6
6
6
7
6
8
F
Note 5: The adjustment data will be automatically input to page:
F, address: 11, 48 to 58.
Processing after Completing Adjustment:
Order Page Address Data
1
6
2
6
3
6
4
0
5
DCR-HC39E/HC41/HC42/HC42E/HC43/HC43E
RadarW
RadarW
RadarW
RadarW
RadarW
Subject more than 500 m away
(Subject with clear contrast such as
buildings, etc.)
Adjusting remote commander
F
11, 48 to 58
Data of page: F, address: 57 is"00" to "0B"
Data of page: 6, address: 0C is"00"
Procedure
01
01
01
13
Press PAUSE button.
Wait for 2 seconds.
Place ND filter on the lens so
that the optimum image is
obtain.
01
29
Press PAUSE button. (Note 5)
02
Check the data changes to "01".
0C
Check the data is "00".
57
Check the data is "00" to "0B".
Procedure
01
00
Press PAUSE button.
01
25
Press PAUSE button.
01
00
Press PAUSE button.
01
00
Perform "Flange Back
Check".
6.
Flange Back Check
Subject
Measurement Point
Measuring Instrument
Specified value
Note 1: Check that the data of page: 0, address: 10 is "00".
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Note 2: When the auto focus is ON, the lens can be checked if it
is focused or not by observing the data on the page: 1 of
the adjusting remote commander.
1 : 00 : XX
Preparations before adjustments:
1) Place the Siemens star 2.0 m from the front of the lens.
2) To open the IRIS, decrease the luminous intensity to the Si-
emens star up to a point before noise appear on the image.
Checking method:
Order Page Address Data
1
6
40
2
6
41
3
4
5
0
03
6
1
7
6
21
8
9
Processing after Completing Adjustment:
Order Page Address Data
1
6
21
2
6
40
3
6
41
4
0
03
6-27
Siemens star
(2.0 m from the front of the lens)
(Luminance: approx. 200 lux)
Check operation on monitor TV
Focused at the TELE end and WIDE
end
Odd: Focused
Even: Unfocused
Procedure
01
01
Shoot the Siemens star with
the zoom TELE end.
Turn on the auto focus.
0F
Check that the lens is
focused. (Note 2)
10
Shoot the Siemens star with
the zoom WIDE end.
Observe the TV monitor and
check that the lens is
focused.
Procedure
00
00
00
00