Manuals and User Guides for GE moisture.IQ. We have
2
GE moisture.IQ manuals available for free PDF download: User Manual
GE moisture.IQ User Manual (182 pages)
Multi-Channel Moisture and Oxygen Analyzer
Brand:
GE
| Category:
Measuring Instruments
| Size: 17.54 MB
Table of Contents
Table of Contents
5
Product Registration
9
Safety Issues
9
Services
9
Terms and Conditions
9
Typographical Conventions
9
Auxiliary Equipment
10
Environmental Compliance
11
Chapter 1. Installation
13
Introduction
13
Unpacking the Moisture.iq
13
Installing the Moisture.iq
13
Choosing an Installation Site
14
General Site Guidelines
14
Low Voltage Directive
14
Moisture Probe Considerations
15
Temperature Range
15
Moisture Condensation
15
Static or Dynamic Use
15
Pressure Range
16
Long-Term Storage & Operational Stability
16
Interference Effects
16
Corrosive Materials
16
Sample System Guidelines
17
Moisture Sample Systems
17
Oxygen Sample Systems
18
Mounting the Hygrometer System
19
Mounting the Electronics Unit
19
Mounting a Sample System
19
Mounting the Oxygen Cell
20
Installing the Probes
21
Moisture Probes
21
Adapting an Existing TF-Series Probe Cable
22
Adapting an Existing M-Series Probe Cable
23
Pressure Sensors
24
Delta F Oxygen Cell
24
Making Electrical Connections
26
Using the Lever to Make Wiring Connections
27
Connecting the Input Power
28
Connecting Moisture Probes
28
Connecting the Delta F Oxygen Cell
33
Establishing a Gas Flow through the Oxygen Cell
38
Connecting an Auxiliary Device
40
Connecting Analog Outputs
41
Connecting Alarms
42
Chapter 2. Operation
43
Powering up
43
Measurement Display Components
43
The Help Button
44
The Data Element Editor
44
Initial Setup
46
Restarting the System
47
Shutting down the System
48
Chapter 3. Using the Settings Menu
51
Introduction
51
Display Settings
52
System Settings
53
File Manager
54
Screen Alignment (Weatherproof and Explosion-Proof)
55
Screen Configuration (Weatherproof and Explosion-Proof)
56
Notifications Setup
57
Fault Alarm Setup
58
Module Setup
59
Service Menu Options
60
Software Update
60
Restart
60
Shut down
60
Chapter 4. Using the Outputs, Alarms and Logger Menus
61
Setting up the Outputs
61
Configuring an Output
61
Testing the Selected Output
62
Trimming the Selected Output
63
Setting the Output Range Error Response
64
Setting up the Alarms
65
Configuring an Alarm
65
Testing the Selected Alarm
66
Setting the Alarm Range Error Response
67
Setting up and Running Logs
68
Chapter 5. Using the Configuration Menu
71
Configuring the Probes
71
The Probe Configuration Screen
72
Configuring Delta F Oxygen Sensor Probes
75
Calibrating Individual Channels
76
Setting the Probe Auto-Cal Schedule
77
Calibrating the Probes
78
Entering Calibration Data Automatically
78
Entering Calibration Data Manually
78
Tagging the Inputs
80
Entering User Information
81
Entering User Functions
81
Entering User-Defined Tables
83
Entering User Constants
84
Entering Saturation Constants
85
Chapter 6. Setting up Communications
87
Setting up Moisture.iq Communications
87
Configuring the Serial Port
87
Configuring the Modbus Connection
88
Connecting to an Ethernet LAN
89
Configuring the Ethernet TCP/IP Connection
89
Capabilities of the Ethernet Connection
90
Configuring a VNC Connection
94
Configuring the Web Server
95
User Management Operations
96
Setting up a Remote Connection to a PC
97
Chapter 7. Maintenance
99
Delta F Oxygen Cell Electrolyte
99
Checking the Electrolyte Level
100
Replenishing the Electrolyte
100
Replacing and Recalibrating Moisture Probes
101
Calibrating the Delta F Oxygen Cell
101
Displaying Oxygen Content in Ppmv and Μa
101
Checking the Oxygen Cell Calibration
102
Delta F Oxygen Cell Background Gas Correction Factors
103
Correcting for Different Background Gases
103
Entering the Background Gas Correction Factor
104
Chapter 8. Troubleshooting
105
Screen Messages
105
Common Problems
108
Chapter 9. Specifications
111
Electronics
111
Moisture Measurement
112
Temperature Measurement
112
Pressure Measurement
113
Oxygen Measurement
113
General Specifications
114
Output Specifications
115
Input Specifications
116
Probe Specifications
117
Sample Requirements
120
Appendix A. Menu Maps
121
The Settings Menu Map
121
The Outputs, Alarms and Logger Menu Map
122
The Configuration > Probe & User Menu Maps
123
The Configuration > Comms Menu Map
124
Appendix B. Wiring Diagrams
125
Terminal Blocks
125
Rear View Channel Configurations
126
Power Wiring
127
Wiring
128
Appendix C. Updating the Moisture.iq Firmware
129
Updating the Chassis Firmware
129
Updating the Moisture.iq Module Firmware
133
Appendix D. Modbus Register Map
139
Analog Outputs
163
Specifications
166
Advertisement
GE moisture.IQ User Manual (178 pages)
moisture and oxygen analyzers
Brand:
GE
| Category:
Analytical Instruments
| Size: 10.41 MB
Table of Contents
Table of Contents
5
Chapter 1. Installation and Wiring
11
Introduction
11
Unpacking the Moisture.iq
11
Installing the Moisture.iq
11
Choosing an Installation Site
12
General Site Guidelines
12
Low Voltage Directive
12
Moisture Probe Considerations
13
Temperature Range
13
Moisture Condensation
13
Static or Dynamic Use
13
Pressure Range
14
Long-Term Storage & Operational Stability
14
Interference Effects
14
Corrosive Materials
14
Sample System Guidelines
15
Moisture Sample Systems
15
Oxygen Sample Systems
16
Mounting the Hygrometer System
17
Mounting the Electronics Unit
17
Mounting a Sample System
17
Mounting the Oxygen Cell
18
Installing the Probes
19
Moisture Probes
19
Adapting an Existing TF-Series Probe Cable
20
Adapting an Existing M-Series Probe Cable
21
Pressure Sensors
22
Delta F Oxygen Cell
22
Making Electrical Connections
24
Using the Lever to Make Wiring Connections
25
Connecting the Input Power
26
Connecting Moisture Probes
26
Connecting the Delta F Oxygen Cell
31
Establishing a Gas Flow through the Oxygen Cell
36
Connecting an Auxiliary Device
38
Connecting Analog Outputs
39
Connecting Alarms
40
Chapter 2. Operation
41
Powering up
41
Measurement Display Components
41
The Help Button
42
The Data Element Editor
42
Initial Setup
43
Restarting the System
44
Shutting down the System
45
Chapter 3. Using the Settings Menu
47
Introduction
47
Display Settings
48
System Settings
49
File Manager
50
Screen Alignment (Weatherproof and Explosion-Proof)
51
Screen Configuration (Weatherproof and Explosion-Proof)
52
Notifications Setup
53
Fault Alarm Setup
54
Module Setup
55
Service Menu Options
56
Software Update
56
Restart
56
Shut down
56
Chapter 4. Using the Outputs, Alarms and Logger Menus
57
Setting up the Outputs
57
Configuring an Output
57
Testing the Selected Output
58
Trimming the Selected Output
59
Setting the Output Range Error Response
60
Setting up the Alarms
61
Configuring an Alarm
61
Testing the Selected Alarm
62
Setting the Alarm Range Error Response
63
Setting up and Running Logs
64
Chapter 5. Using the Configuration Menu
67
Configuring the Probes
67
The Probe Configuration Screen
68
Configuring Delta F Oxygen Sensor Probes
71
Calibrating Individual Channels
72
Setting the Probe Auto-Cal Schedule
73
Calibrating the Probes
74
Entering Calibration Data Automatically
74
Entering Calibration Data Manually
74
Tagging the Inputs
76
Entering User Information
77
Entering User Functions
77
Entering User-Defined Tables
79
Entering User Constants
80
Entering Saturation Constants
81
Chapter 6. Setting up Communications
83
Setting up Moisture.iq Communications
83
Configuring the Serial Port
83
Configuring the Modbus Connection
84
Connecting to an Ethernet LAN
85
Configuring the Ethernet TCP/IP Connection
85
Capabilities of the Ethernet Connection
86
Configuring a VNC Connection
90
Configuring the Web Server
91
User Management Operations
92
Setting up a Remote Connection to a PC
93
Chapter 7. Maintenance
95
Delta F Oxygen Cell Electrolyte
95
Checking the Electrolyte Level
96
Replenishing the Electrolyte
96
Replacing and Recalibrating Moisture Probes
97
Calibrating the Delta F Oxygen Cell
97
Displaying Oxygen Content in Ppmv and Μa
97
Checking the Oxygen Cell Calibration
98
Delta F Oxygen Cell Background Gas Correction Factors
99
Correcting for Different Background Gases
99
Entering the Background Gas Correction Factor
100
Chapter 8. Troubleshooting
101
Screen Messages
101
Common Problems
103
Chapter 9. Specifications
105
Electronics
105
Analog Outputs
105
Moisture Measurement
106
Temperature Measurement
107
Pressure Measurement
107
Oxygen Measurement
108
General Specifications
109
Output Specifications
110
Input Specifications
111
Probe Specifications
111
Appendix A. Menu Maps
117
The Settings Menu Map
117
The Outputs, Alarms and Logger Menu Map
118
The Configuration>Probe & User Menu Maps
119
The Configuration>Comms Menu Map
120
Appendix B. Wiring Diagrams
121
Terminal Blocks
121
Rear View Channel Configurations
122
Power Wiring
123
Wiring
124
Appendix C. Updating the Moisture.iq Firmware
125
Updating the Chassis Firmware
125
Updating the Moisture.iq Module Firmware
129
Appendix D. Modbus Register Map
135
Advertisement
Related Products
GE Mentor Visual iQ
GE Model 592
GE GE MONOGRAMTM ZET837DBSB
GE Monogram ZCGS150P
GE Modular MAC Trolley
GE Monogram MOCTWORH104
GE Monogram MOCTWODW108
GE MOA 280i
GE Monogram Wine Reserve 25
GE Monogram GCG1580P
GE Categories
Refrigerator
Ranges
Microwave Oven
Air Conditioner
Dishwasher
More GE Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL