Manuals and User Guides for Huawei NetCol8000-A060U. We have
4
Huawei NetCol8000-A060U manuals available for free PDF download: User Manual, Quick Manual
Huawei NetCol8000-A060U User Manual (369 pages)
In-room Air Cooled Smart Cooling Product
Brand:
Huawei
| Category:
Air Conditioner
| Size: 41.81 MB
Table of Contents
About this Document
3
Table of Contents
5
1 Safety Information
11
General Safety
11
Personnel Requirements
14
Electrical Safety
14
Installation Environment Requirements
16
Mechanical Safety
18
Cooling System Safety
20
Others
21
2 Product Description
22
Model Number Description
22
Indoor Unit Model Number Description
22
Outdoor Unit Model Number Description
23
Water-Cooled Module Model Number Description
24
Overview
25
Component Description
28
Indoor Unit
28
Indoor Unit
29
Display Module
37
Main Control Module
40
Outdoor Unit
43
Low Temperature Component
43
Water-Cooled Module
44
Physical Ports
45
3 Technical Specifications
47
Indoor Unit
47
Outdoor Unit
50
Low Temperature Component
54
Water-Cooled Module
55
Operating Environment
56
4 System Installation
61
Installation Requirements
61
Layout Principles (Netcol500-A060/Netcol500-A080/Netcol500-A120)
61
Layout Principles (Netcol500-A110)
62
Requirements for Installing the Indoor Unit
63
Outdoor Unit Installation Requirements
66
Installation Requirements for the Water-Cooled Module
71
Installation Preparation
73
Tools
73
Materials
76
Refrigerant
77
Refrigerant Oil
78
Refrigerant Pipe Components
78
Humidifier Water Inlet Pipe
80
Drainpipe
80
Water Inlet and Outlet Pipes for the Water-Cooled Module
81
Pipe Support
82
Cable
82
Unpacking and Checking
85
Installing the Indoor Unit
86
Checking the Indoor Unit Pressure
86
Removing the Transport Fixing Sheet Metals
88
Removing the Indoor Unit Pallet
88
Removing the Transport Fasteners from the Compressor
89
Securing the Indoor Unit
90
Installing an Outdoor Unit
90
Checking the Outdoor Unit Pressure
90
Removing the Outdoor Unit Pallet
92
Installing an Outdoor Unit
93
Horizontal Installation Scenario (Netcol500-A060/Netcol500-A080/Netcol500-A120)
93
Horizontal Installation Scenario (Netcol500-A110)
95
Vertical Installation Scenario (Netcol500-A060/Netcol500-A080)
95
Vertical Installation (Netcol500-A120)
100
Installing the Water Cooling Module
102
Checking the Nitrogen Pressure
102
Removing the Pallet
103
Securing a Water Cooling Module
103
Optional) Installing a Low Temperature Component
104
Checking the Nitrogen Pressure
104
Removing Transport Fasteners
105
Securing the Low Temperature Component
105
Connecting Pipelines
106
Notices for Laying Pipes
106
Welding Indoor Unit Pipes
109
Connecting Outdoor Unit Pipes
117
Optional) Welding Pipes for the Low Temperature Component
118
Welding the Water Cooling Module
119
Installing Cooling Water Pipes for the Water Cooling Module
120
Optional) Connecting the Humidifier Water Inlet Pipe
120
Connecting the Drainpipe
121
Leakage Test with Nitrogen
125
Optional) Leakage Test with Water for the Water-Cooled Module
130
Connecting Cables
131
Connecting the Equipotential Ground Cable
131
Connecting Power Cables
132
Connecting Signal Cables
139
Connecting the Signal Cable between the Outdoor Unit and Indoor Unit
139
Connecting Water Sensor Cables
141
Optional) Installing a Micro Differential Pressure Sensor
143
Optional) Connecting T/H Sensors Outside Cabinets
146
Optional) Installing Teamwork and Monitoring Communications Cables
148
Preparing a Network Cable
148
CAN Teamwork + RS485 Monitoring
149
CAN Teamwork + FE Monitoring
151
FE Teamwork + RS485 Monitoring
151
FE Teamwork + FE Monitoring
153
Optional) Installing a Cap (Applicable to Upflow Units)
154
Lowering a Fan (Applicable to Downflow Units)
157
5 Verifying the Installation
160
Indoor Unit Installation Verification
160
Outdoor Unit Installation Verification
162
Checking the Water Cooling Module
163
6 Power-On Commissioning
164
Vacuumizing and Precharging Refrigerant
164
Requirements on the Filling Amount of Refrigerant and Refrigerant Oil
164
Vacuumizing
167
Precharging Refrigerant
172
Preparing for Power-On
178
Power-On
179
Home Screen
187
Initial Configuration
189
Setting T/H Sensor Parameters
189
Optional) Setting the Pressure Difference Control
192
Optional) Setting Teamwork Parameters
192
Setting Communications Parameters
198
Setting Access Control Parameters
198
Setting Communications Parameters (Modbus-RTU Protocol)
199
Setting Communications Parameters (Modbus-TCP Protocol)
200
Setting Communications Parameters (SNMP Protocol)
201
Optional) Setting Wifi Parameters
204
Startup
205
Charging the Remaining Refrigerant
209
Wizard Startup
210
Optional) Power-Off
212
Checking after Commissioning
212
7 Webui
214
Preparations and Webui Login
214
Introduction to the Webui
217
8 Operation and Maintenance
218
Data Record
218
Indoor Unit Routine Maintenance
219
Monthly Maintenance
219
Quarterly Maintenance
220
Yearly Maintenance
221
Outdoor Unit Routine Maintenance
222
Monthly Maintenance
222
Semi-Annual Maintenance
223
Water Cooling Module Routine Maintenance
224
Monthly Maintenance
224
Semi-Annual Maintenance
225
9 Troubleshooting
226
10 Alarm Reference
231
11 Parts Replacement
266
Replacing an Air Filter
266
Replacing a Differential Pressure Switch
268
Replacing a Drive
269
Replacing a Fan Drive (Netcol8000-A055/A060/A120)
270
Replacing a Wet Film Humidifier
272
Replacing an Electric Heater
273
Replacing an Electric Heater (Upflow)
274
Replacing an Electric Heater (Downflow)
275
Replacing a Compressor
276
Replacing a Filter Dryer
280
Replacing an Indoor Fan
282
Replacing an Indoor Fan (Netcol8000-A045U)
282
Replacing an Indoor Fan (Netcol8000-A060U)
285
Replacing an Indoor Fan (Downflow)
287
Replacing a Liquid Level Detector
290
Replacing an Outdoor Fan
291
Replacing a Display Module
293
12 Faq
296
How Do I Issue a Start/Shutdown Command
296
Operations with a USB Flash Drive
297
How Do I Export Data
298
How Do I Import and Export a Configuration File
299
How Do I Import a Certificate and Key
300
Display Module Screen Operations
301
How Do I Set LAN Parameters
301
How Do I Check Temperature and Humidity Curves
302
How Do I View Logs
303
How Do I View Component Status
303
How Do I View System Parameters
304
How Do I View Version Information
304
How Do I View the Service Information
304
How Do I Check Teamwork Control Information
305
How Do I Mute or Silence a Buzzer
305
How Do I Handle Alarms
305
How Do I Clear Component Runtime
306
How Do I Calibrate a T/H Sensor
307
How Do I Change the Password
307
How Do I Set Alarm Parameters
308
How Do I Commission a Component
309
How Do I Query the Setting of a Parameter before Change
310
Webui Operations
310
How Do I Manage Webui Users
311
How Do I Install a Network Security Certificate
313
How Do I View Active Alarms and Historical Alarms
313
How Do I Export or Import a Configuration File
314
How Do I Export Fault Information
314
How Do I Change an IP Address
315
How Do I View Version Information
315
A Electric Control Box Layout
316
Indoor Unit
316
Netcol8000-A045/A090/A055
316
Netcol8000-A060/A120
319
Outdoor Unit
320
Netcol500-A060
320
Netcol500-A080
322
Netcol500-A120
324
Netcol500-A110
324
Netcol500-W055
325
B Base
326
Indoor Unit
326
Netcol8000-A045D
326
Netcol8000-A045U
327
Netcol8000-A055D
328
Netcol8000-A060D
329
Netcol8000-A060U
330
Netcol8000-A090D
331
Netcol8000-A120D
332
Outdoor Unit
332
Low Temperature Component
333
Netcol500-A060
334
Netcol500-A080
341
Netcol500-A110
346
Netcol500-A120
347
Netcol500-W055
350
C Cooling Component Layout
351
D Power Cable Filter for an Outdoor Unit
352
E Electrical Diagrams
353
Indoor Unit
353
Netcol8000-A045
353
Netcol8000-A055
355
Netcol8000-A060
357
Netcol8000-A090
359
Netcol8000-A120
361
Outdoor Unit
362
Netcol500-A060
363
Netcol500-A080
364
Netcol500-A110
365
Netcol500-A120
366
Netcol500-W055
367
F Acronyms and Abbreviations
368
Advertisement
Huawei NetCol8000-A060U Quick Manual (41 pages)
In-room Air Cooled Smart Cooling Product
Brand:
Huawei
| Category:
Computer Hardware
| Size: 6.9 MB
Table of Contents
Product Overview
1
Engineering Materials
2
Refrigerant
3
Installing the Indoor Unit
4
Oil Trap and Inverted Trap (Unit: MM)
4
Mapping between Saturation Temperatures and Pressure of R410A
4
Checking Whether the Nitrogen Is Discharged at the Three Needle Valves
5
Removing the Pallet
5
Removing Compressor Fasteners
6
Securing to the Floor or Base
6
Lowering a Fan (Applicable to Downflow Units)
6
Installing the Outdoor Unit
7
Checking Whether the Nitrogen Is Discharged
7
Installation Scenario
7
Horizontal Installation of the Outdoor Unit
8
Vertical Installation of the Outdoor Unit
9
Welding Refrigerant Pipes
10
Laying the Engineering Pipe
10
Discharging Nitrogen of Indoor Unit
10
Welding the Indoor Unit Ports
11
Discharging Nitrogen at the Outdoor Unit Needle Valves
12
Connecting Water Pipes
13
Welding the Outdoor Unit Ports
13
Connecting Low Temperature Component Pipes
13
Connecting the Humidifier Water Inlet Pipe
13
Connecting the Drainpipe
14
Installing Cables
15
Connecting the Indoor Unit Power Cable
15
Connecting the Outdoor Unit Power Cable
17
Connecting the Signal Cable of Outdoor Unit and Indoor Unit
18
Connecting the Equipotential Bonding Cable
19
Connecting a Differential Pressure Sensor
19
Connecting the Low-Temperature Component Cables
20
Connecting the Water Sensor
21
Connecting the T/H Sensors Outside Cabinets
21
Connecting the Teamwork Network Cable
22
CAN Teamwork Networking (CAN Protocol)
22
RS485 Monitoring Network Cable (Modbus-RTU Protocol)
22
FE Monitoring Network Cable (Snmp/Modbus-TCP Protocol)
23
Installing the Cap (Applicable to Upflow Units)
24
Post-Installation Check
25
Leak Checking, Vacuuming, and Precharging Refrigerant
25
Scenarios Without a Low-Temperature Component
27
Scenarios with a Low-Temperature Component
28
Power-On
31
Configuring Initial Parameters
31
Teamwork Settings
32
Startup and Configuration
33
FE Monitoring Network Cable (Modbus-TCP Protocol/Snmp Protocol)
33
Optional) Setting Communications Parameters
33
Startup and Commissioning
33
First Startup Flowchart
34
Wizard Startup Flowchart
34
Power-Off
35
Checking after Commissioning
35
Appendix 1: Base Dimensions
35
Appendix 2: Indoor Unit Base Dimensions
39
Huawei NetCol8000-A060U Quick Manual (47 pages)
Brand:
Huawei
| Category:
Air Conditioner
| Size: 5.56 MB
Table of Contents
Product Overview
2
Onsite Preparation
3
Installing the Indoor Unit
6
Installing the Outdoor Unit
8
Connecting Refrigerant Pipes
15
Connecting Water Pipes
21
Installing Cables
23
(Optional) Power-Off
46
Advertisement
Huawei NetCol8000-A060U Quick Manual (38 pages)
In-room Air Cooled Smart Cooling Product
Brand:
Huawei
| Category:
Air Conditioner
| Size: 5.05 MB
Table of Contents
Product Overview
2
Installing the Indoor Unit
5
Removing the Pallet
6
Installing the Outdoor Unit
7
Installation Scenario
8
Connecting the Humidifier Water Inlet Pipe
17
Connecting the Drainpipe
17
Installing Cables
18
Water Sensor
24
Leak Checking
28
Precharging Refrigerant
28
Startup Process
35
(Optional) Power-Off
37
Advertisement
Related Products
Huawei NetCol8000-A Series
Huawei NetCol8000-A045D
Huawei NetCol8000-A045U
Huawei NetCol8000-A060D
Huawei NetCol8000-A090D
Huawei NetCol8000-A120D
Huawei NetCol500-A110
Huawei NIP6800 Series
Huawei NIP6860
Huawei NetCol8000-A013
Huawei Categories
Cell Phone
Network Router
Wireless Router
Modem
Inverter
More Huawei Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL