Sign In
Upload
Manuals
Brands
LG Manuals
Heat Pump
Therma V AHUW096A3
LG Therma V AHUW096A3 Manuals
Manuals and User Guides for LG Therma V AHUW096A3. We have
6
LG Therma V AHUW096A3 manuals available for free PDF download: Installation Manual, Engineering Product Data Book, Service Manual, Owner's Manual
LG Therma V AHUW096A3 Installation Manual (145 pages)
AIR-TO-WATER HEAT PUMP
Brand:
LG
| Category:
Heat Pump
| Size: 24.13 MB
Table of Contents
Table of Contents
2
Table of Contents
3
Preface
4
Important Safety Instructions
5
Installation Part
12
General Information
13
Model Information
13
Model Name and Related Information
14
Parts and Dimensions
15
Control Parts
20
Control Panel
21
Typical Installation Example
24
Cycle Diagram
29
Water Cycle
30
Installation of Outdoor Unit
32
Conditions Where Outdoor Unit Is Installed
32
Drill a Hole in the Wall
32
Installation at Seaside
33
Seasonal Wind and Cautions in Winter
33
Installation of Indoor Unit
34
Conditions Where Indoor Unit Is Installed
34
Electrical Wiring
37
Piping and Wiring for Outdoor Unit
40
Refrigerant Piping
40
Preparation for Piping
41
Connecting Pipe to Indoor Unit
42
Connecting Pipe to Outdoor Unit
42
Finalizing
45
Leakage Test and Evacuation
46
Electrical Wiring
48
Piping and Wiring for Indoor Unit
51
Water Piping and Water Circuit Connection
51
Water Pump Capacity
54
Pressure Drop
54
Performance Curve
55
Water Quality
56
Frost Protection
56
Water Volume and Expansion Vessel Pressure
57
Accessories Installation
58
Before Installation
60
Thermostat
60
Central Controller
65
DHW Tank and DHW Tank Kit/Solar Thermal Kit
66
Dry Contact
73
2Way Valve
74
3Way Valve
75
Air-Vent
76
Final Check
77
Configuration
78
DIP Switch Setting
78
Service Setting
83
How to Enter Service Setting
83
Service Contact
84
Model Information
85
RMC Version Lnformation
86
Open Source License
87
Installer Setting
88
How to Enter Installer Setting
88
Installer Setting
89
TH On/Off Variable, Cooling Air
90
TH On/Off Variable, Cooling Water
90
Pump Setting in Heating
90
Pump Setting in Cooling
90
Forced Operation
90
91 3 Minutes Delay
91
Select Temperature Sensor
92
Dry Contact Mode
93
Central Control Address
94
Pump Test Run
95
Air Cooling Set Temp
96
Water Cooling Set Temp
97
Air Heating Set Temp
98
Water Heating Set Temp
99
DHW Set Temp
100
Screed Drying
101
Heater on Temperature
103
Water Supply off Temp. During Cooling
105
Tank Disinfection Setting
107
Tank Setting 1
108
Tank Setting 2
109
Heater Priority
111
DHW Time Setting
112
TH On/Off Variable, Heating Air
113
TH On/Off Variable, Heating Water
114
TH On/Off Variable, Cooling Air
115
TH On/Off Variable, Cooling Water
116
Pump Setting in Heating
117
Pump Setting. in Cooling
118
Forced Operation
119
Cn_Cc
120
Pump Frequency Setting (RPM)
121
Smart Grid(SG)
122
Seasonal Auto Temp
123
Modbus Address
125
Cn_Ext
126
Add Zone
127
Use External Pump
128
3Rd Party Boiler
129
Rd Party Boiler
129
Meter Interface
130
Data Logging
132
Password Initialization
133
Power Supply Blockage (SG Ready)
134
Overview Settings
135
Commissioning
137
Check List before Starting Operation
137
Starting Operation
138
Starting Operation Flow Chart
139
Airborne Noise Emission
139
Limiting Concentration
139
Troubleshooting
140
Advertisement
LG Therma V AHUW096A3 Installation Manual (87 pages)
AIR-TO-WATER
Brand:
LG
| Category:
Heat Pump
| Size: 16.42 MB
Table of Contents
Table of Contents
2
Preface
5
1 Safety Precaution
6
Warning
6
Installation Warning
6
Operation Warning
7
Caution
9
Installation Caution
9
Operation Caution
9
2 Installation Part
10
Indoor Unit Box
10
Outdoor Unit Box
10
3 General Information
11
Model Information
11
Typical Installation Example
13
Case 1
13
Case 2
14
Case 3
15
Cycle Diagram
16
Water Cycle
17
Parts and Dimensions
19
Indoor Unit(External)
19
Indoor Unit(Internal)
20
Outdoor Unit(External)
22
Control Parts
24
Control Box : Indoor Unit
24
Control Panel
25
Wiring Diagram : Indoor and Outdoor (Incl. Field Wiring)
26
4 Installation of Outdoor Unit
28
Conditions Where Outdoor Unit Is Installed
28
Drill a Hole in the Wall
28
Installation at Seaside
29
Seasonal Wind and Cautions in Winter
29
5 Installation of Indoor Unit
30
Conditions Where Indoor Unit Is Installed
30
General Considerations
30
Service Space
30
Mounting to Wall
31
Water Volume and Water Pump Capacity
32
Pressure Drop
34
Water Volume and Expansion Vessel Pressure
35
Water Quality
36
Frost Protection
36
6 Piping and Wiring for Outdoor Unit
37
Refrigerant Piping
37
Constraints in Pipe Length and Elevation
37
Preparation for Piping
38
Connecting Pipe to Indoor Unit
39
Connecting Pipe to Outdoor Unit
39
Circuit Breaker Specification
42
Wiring Procedure for Power Cable and Connecting Cable
43
Finalizing
44
Pipe Forming
44
Leakage Test and Evacuation
45
Preparation
45
Leakage Test
45
Evacuation
46
7 Piping and Wiring for Indoor Unit
47
Water Piping and Water Circuit Connection
47
General Considerations
47
Water Charging
49
Pipe Insulation
49
Electrical Wiring
50
General Consideration
50
Terminal Block Information
51
Connecting with Outdoor Unit
52
Electric Heater Wiring
52
8 Accessories Installation
53
ACCESSORIES SUPPORTED by LG Electronics
53
ACCESSORIES SUPPORTED by 3Rd PARTY COMPANIES
53
Before Installation
54
Thermostat
54
General Information
54
How to Wire Thermostat
55
Final Check
56
Dhw Tank and Dhw Tank Kit/Solar Thermal Kit
57
General Information
57
How to Install Dhw Tank
58
How to Install Dhw Tank Kit
59
How to Wire Dhw Tank Heater
61
How to Install Solar Thermal Kit
62
Dry Contact
62
Remote Temperature Sensor
62
3Way Valve
63
How to Wire 3Way Valve
63
Final Check
63
2Way Valve
64
General Information
64
How to Wire 2Way Valve
64
Final Check
64
Conditions if Accessories Are Installed
65
Thermostat
65
Remote Air Temperature Sensor
65
Dhw Tank and Dhw Tank Kit / Solar Thermal Kit
66
9 System Set-Up
68
Dip Switch Setting
68
General Information
68
Dip Switch Information
69
Installer Setting
72
How to Enter Installer Setting Mode
72
Summary
73
Common Setting
74
Temperature Range Setting
75
Temperature Control Parameter Setting
76
10 Check Points, Maintenance and Troubleshooting
81
Check List before Starting Operation
81
Maintenance
82
Test Run
82
Check before Test Run
82
Troubleshooting
83
Troubleshooting for Problem While Operation
83
Troubleshooting for Error Code
84
Airborne Noise Emission
85
Limiting Concentration
85
LG Therma V AHUW096A3 Engineering Product Data Book (116 pages)
Air-to-Water Heat Pump/Split Type R410A/50Hz, Total HVAC Solution Provider
Brand:
LG
| Category:
Air Conditioner
| Size: 27.02 MB
Table of Contents
Split Type
2
General Information
3
Outdoor Units
4
Outdoor Unit
7
Indoor Unit
9
List of Functions
12
Specifications
13
Wiring Diagrams
17
Piping Diagram
19
Hydraulic Performance
21
Water Volume and Pump Capacity
21
Water Volume and Expansion Vessel Pressure
22
Sound Power Level
23
Installation
24
Water Control
24
Water Quality
24
Frost Protection
24
General Considerations
25
Test Run Flow Chart
31
Check List before Starting Operation
32
Maintenance
33
Check Point
33
Check before Test Run
33
Safety Precautions
34
Specification
34
Name of each Part
35
Installation Inside of the Indoor Unit
36
Setting Method
36
Connecting Drycontact with Indoor Unit PCBA and Modbus Controller
36
Setting Address
37
Remote Temperature Sensor (PQRSTA0)
38
Part Description
38
Installation Method
39
How to Use
39
How to Install
43
List of Functions
48
Technical Specifications
49
Electrical Specifications
50
Wiring Diagrams
52
Piping Diagrams
56
Installation
60
Water Piping and Water Circuit Connection
61
DIP Switch Configuration
66
Performance Data
84
Operation Range
102
Electric Characteristics
103
Wiring of Main Power Supply and Equipment Capacity
103
Select the Best Location
107
Installation Space
108
Foundation for Installation
110
Finishing the Job
111
Advertisement
LG Therma V AHUW096A3 Service Manual (82 pages)
AIR-TO-WATER HEAT PUMP
Brand:
LG
| Category:
Heat Pump
| Size: 21.23 MB
Table of Contents
Table of Contents
2
General
3
Definitions
3
Symbol
3
Safety Warnings and Instructions
4
Installation
4
Operation
5
Indoor
8
Specification
8
Outdoor
10
Function Table
13
Pump Capacity
14
Pump Hydraulic Performance
14
Piping Diagrams
15
Wiring Diagrams
16
Outdoor Unit
18
Models : AHUW166A3, AHUW146A3, AHUW126A3
19
Indoor Unit
21
Exploded View
21
Model Number Nomenclature
29
Model Information
29
Model Name and Related Information
30
Replacement Procedure for Compressor
31
Caution for Assembling Outdoor Panels after Test Run
32
Humidity of the Controller Assembly
33
Supply Voltage
33
Trouble Shooting Guide (Indoor Unit)
33
Module 1 - Alarm
35
Module 2 - Alarm
36
Position of Temperature Sensor
37
ERROR .Thermostat
37
Alarm Rtc Fail
38
Alarm Dhw
39
Module Inv Alarm
39
Main PCB Assembly(Inverter)
40
Trouble Shooting Guide (Outdoor Unit)
40
Error Diagnosis and Countermeasure Flow Chart
41
Comp Checking Method
41
Ahuw096A3
42
Check Point
46
Items for Checking
62
Sub-Items for Checking
62
Insufficient Insertion of Wires
63
Damage of Wire Coating
63
Inverter PCB LED
63
Judgment Method of R,S,T Phase Loss
66
Judgment Method of Open and Reverse Phase of R,S,T
66
Sensor Resistance Table (in Outdoor Unit)
78
Heatsink Temp
79
D-Pipe Temp
79
How to Check Insulation Resistance between the Compressor and Panel
80
How to Check the U, V, and W Phase Resistance
80
LG Therma V AHUW096A3 Installation Manual (65 pages)
AIR-TO-WATER HEAT PUMP
Brand:
LG
| Category:
Heat Pump
| Size: 12.97 MB
Table of Contents
Table of Contents
2
Important Information
3
Symbols
3
General
4
Safety Warnings and Instructions
4
Obligations of the Manufacturer
8
Obligations of the Installer During Installation
8
Obligations of the User
8
Installation Part
9
General Information
10
Model Information
10
Parts and Dimensions
12
Installation of Outdoor Unit
15
Conditions Where Outdoor Unit Is Installed
15
Set up and Connection of the External Sensor
16
Drill a Hole in the Wall
16
Installation at Seaside
17
Seasonal Wind and Cautions in Winter
17
Installation of Indoor Unit
18
General
18
Location of the Device
19
Connection with the Outdoor Unit
21
Hydraulic Connection
25
Electrical Connection
34
Refrigerant Piping
47
Piping and Wiring for Outdoor Unit
47
Finalizing
56
Leakage Test and Evacuation
57
System Set-Up
59
DIP Switch Setting
59
Check Points, Maintenance and Troubleshooting
60
Check List before Starting Operation
60
Care and Maintenance
61
Test Run
63
Limiting Concentration
63
Search the Manual Using Your Mobile
64
Airborne Noise Emission
64
LG Therma V AHUW096A3 Owner's Manual (35 pages)
AIR-TO-WATER HEAT PUMP
Brand:
LG
| Category:
Heat Pump
| Size: 2.8 MB
Table of Contents
Table of Contents
2
Safety Precautions
3
Product Introduction
8
Operation Setting
10
Temperature Setting
12
Low Noise Mode
15
Lock Setting
17
Date Setting
19
Timer Setting
20
Schedule Setting
25
Using Thermostat
27
Maintenance and Service
30
Advertisement
Related Products
LG AHUW096A0
LG AHUW096A1
LG AHUW096AN
LG Therma V AHUW096A2
LG THERMA V AHUW076A3
LG AHUW148A1
LG AHUW128A1
LG AHUW166A1
LG Therma V AHUW126A2
LG THERMA V AHUW146A3
LG Categories
Cell Phone
Monitor
LED TV
Washer
Air Conditioner
More LG Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL