Sign In
Upload
Manuals
Brands
Siemens Manuals
Voice Recorder
SIMEAS R-PMU
Siemens SIMEAS R-PMU Manuals
Manuals and User Guides for Siemens SIMEAS R-PMU. We have
2
Siemens SIMEAS R-PMU manuals available for free PDF download: Manual, Maintenance Manual
Siemens SIMEAS R-PMU Manual (296 pages)
Digital Fault Recorder
Brand:
Siemens
| Category:
Measuring Instruments
| Size: 11.08 MB
Table of Contents
Table of Contents
7
1 Introduction
13
2 Applications
15
Recording Systems in Power Plants
16
Recording Systems in Communications Systems
17
Recording Systems in High-Voltage Direct Current Substations
18
Recording Systems in Distribution Systems and Industrial Complexes
18
3 System Overview
19
4 Device Overview
23
Device Architecture
24
Central Processing Module (CPU)
25
Data Acquisition Modules
26
Types and Design of Data Acquisition Modules
26
Features of the Individual Acquisition Modules (Daus)
27
Time Synchronization
28
Interfaces
29
Control Panel
30
Voltage Supply
31
Housing Versions
32
5 Connection Principles
33
General
34
Star Connection
36
Delta Connection
38
Monophase Connection
39
6 Measuring Principles
41
Measured Value Acquisition and Processing
42
Measured Values and Calculation Values
46
Calculating Derived Values
47
Voltage, Current and Power
47
Symmetrical Components
48
7 Recording Functions
51
Phasor Measurement Unit (PMU)
52
Recording Channels
56
Data Communication of the SIMEAS R-PMU
58
Fault Recorders
64
Transient Analog Recorder (TAR)
64
Recording Channels
65
Trigger Functions
67
Analog Signal Triggers
70
Level Trigger (Min/Max)
71
Gradient Trigger (±DM/Dt)
72
Binary Trigger
72
Logical Trigger
73
Cross Trigger
74
Manual Triggers
74
External Trigger
74
Network Trigger
75
Transient Phasor Recorder (TPR)
76
Recording Channels
77
Trigger Functions
80
Analog Signal Triggers
84
Level Trigger (Min/Max)
86
Gradient Trigger (±DM/Dt)
87
Binary Trigger
89
Cross Trigger
90
Manual Triggers
90
External Trigger
90
Network Trigger
91
Continuous Recorder
92
Continuous Phasor Recorder (CPR)
94
Continuous Mean Value Recorder for Frequencies (CFR)
97
Continuous Mean Value Recorder for RMS-Values (CRR)
98
Continuous Mean Value Recorder for Active and Reactive Power (CQR)
99
Continuous Mean Value Recorder for Process Values (CDR)
101
Event Recorder
102
8 Time Synchronization
103
General
104
Synchronization Types
105
Minute Pulse Synchronization
105
GPS Synchronization Via DCF77 Second Signal
105
Timers and Time Delay
106
Commissioning
108
Fault Handling
109
Minute Pulse
109
GPS/DCF77 and Sync-Box
110
Fault Elimination
110
9 Setting the Time
111
10 Communication Options and Connections
115
General
116
LAN Communication
116
Connection
116
Settings
121
COM S - Maintenance Interface (Service Interface)
124
COM 1 Interface
125
Serial Direct Connection
125
Communication Via External Modem
126
Star Coupler
127
Communication
128
11 Local Printer
129
12 Parameterization Via OSCOP P
131
General
132
Configuration
138
Local Printer
140
Time Synchronization
141
SIMEAS R-PMU Calling Master Station
142
Device Function
143
Interfaces
146
Data Interface
146
LAN Interface
148
Service Interface
149
LED Indications
150
Relay Indications
151
Group Alarm
152
Slot Description
153
Binary Channels
154
Analog Channels
155
Power/Frequency
157
Symmetrical Components
159
DC Channels
160
Transient Analog Recorder (TAR)
162
Time Settings
162
Analog Triggers
163
Binary Triggers
164
Network and Cross Triggers
165
Trigger Pattern
166
DC Triggers
167
Transient Phasor Recorder (TPR)
168
Time Settings
168
Analog Triggers
169
Binary Triggers
170
Network and Cross Triggers
171
DC Triggers
172
Phasor Measurement Unit (PMU)
173
PMU Settings
173
PMU Interface
174
13 System Monitoring
175
System Monitoring
176
Operator and Error Messages
177
General
177
Behaviour with Critical Faults
182
14 Installation and Commissioning
183
Getting Started
184
Unpacking and Repacking the Device
184
Device Inspections Upon Receipt
185
Check of the Rated Data
185
Electrical Check
185
Operation with OSCOP P
185
Transport
186
Storage
187
Installation and Connection
188
Installation
189
Connecting Cables
190
Earthing, Shielding and Connecting Peripheral Devices
191
Connecting Cables (Power Supply, Signals, Measurement Circuits)
193
Connecting the Power Supply to the Power Supply Unit
194
Connecting Signals to the CPU
194
Connecting Data Acquisition Modules VCDAU, VDAU, CDAU
194
Connecting the Data Acquisition Module DDAU
195
Connecting the Data Acquisition Module BDAU
195
Connecting the Cables (Data Transmission)
196
Connecting the PC, PDC or Notebook Via LAN
196
Connecting the PC or Notebook to COM S
196
Connecting the PC, PDC or External Modem to COM
196
Connecting the Printer to the PRINTER Port
196
Cable Assemblies for Connection
197
Extending the Existing Hardware
198
Extending a SIMEAS R-PMU by Additional Data Acquisition Modules
199
Replacing Data Acquisition Modules of Different Types
202
Extending a SIMEAS R-PMU by Communication Components
203
Extending a SIMEAS R-PMU by External Modules
205
Clock
205
Printer
206
Commissioning
207
Start-Up of the SIMEAS R-PMU
207
Parameterization of the SIMEAS R-PMU
209
Operation of the SIMEAS R-PMU
209
15 Design
211
Device Overview
212
Housing Versions
213
Panel Flush Mounting; ZE
213
19-Inch Frame; ZE
214
Panel Flush Mounting (ZE 32/64)
215
19-Inch Frame; ZE
217
Surface Mounting; ZE
218
Surface Mounting; ZE
219
Ordering Information and Accessories
220
Location Diagrams
221
Location Diagram, ZE 8/16 with VCDAU
221
Location Diagram, ZE 8/16 with VDAU
223
Location Diagram, ZE 8/16 with CDAU
224
Location Diagram, ZE 8/16 with BDAU
225
Location Diagram, ZE 8/16 with DDAU
226
Location Diagram, ZE 32/64 with VDAU, CDAU, DDAU, BDAU
227
Location Diagram, ZE 32/64 with 2 X VCDAU
229
Location Diagram, ZE 32/64 with 4 X VCDAU
230
Location Diagram, ZE 32/64 with 1 X VCDAU and 3 X CDAU
231
Connection Diagrams (Power Supply, Signals, Measurement Circuits)
232
CPU and Power Supply Unit
232
Cdau
233
Ddau
234
Bdau
235
Vcdau
236
Vdau
237
Channel Assignment Diagrams
238
Channel Assignment Diagram, ZE 8/16 with VCDAU
238
Channel Assignment Diagram, ZE 32/64 with VDAU, CDAU, DDAU, BDAU
239
16 Technical Data
241
Technical Data of the SIMEAS R-PMU
242
Construction
242
Supply Voltage
242
Phasor Measurement Unit (PMU)
244
Analog and Binary Inputs and Outputs
245
Communication Interfaces
250
Time Synchronization
250
Electrical Tests
251
Mechanical Stress Tests
254
Climatic Tests
255
Packaging
256
Mass and Device Dimensions
257
Technical Data of the Battery
258
17 Frequently Asked Questions (FAQ)
259
18 Overview of Functions
261
Modules of the SIMEAS R-PMU
262
Data Acquisition Units (DAU)
264
Recording Functions
267
Time Synchronization
273
Appendix
275
Product Information SIMEAS R
276
Error Messages
279
System Messages
280
Abbreviations
287
Special Note Open Source Software
289
Advertisement
Siemens SIMEAS R-PMU Maintenance Manual (102 pages)
digital fault recorder
Brand:
Siemens
| Category:
Voice Recorder
| Size: 5.76 MB
Table of Contents
German
7
Table of Contents
7
Batterie und Akkupack
9
Batterie auf der CPU-Baugruppe
9
Allgemeines
9
Auswechseln der Batterie
9
Akkupack auf der Netzteilbaugruppe (Option)
15
Allgemeines
15
Auswechseln des Akkupacks
16
Test des Akkupacks
22
Sicherung
23
Allgemeines
23
Auswechseln der Feinsicherung F1
24
Massenspeicher
31
Allgemeines
31
Öffnen des Gerätes
32
Auswechseln des Massenspeichers
36
Auswechseln einer 2,5"-Flash Disk gegen eine 2,5"-Flash Disk
36
Auswechseln einer 2,5"-Flash Disk gegen einen DOM-Flash-Speicher
40
Auswechseln eines DOM-Flash-Speichers gegen einen DOM-Flash-Speicher
42
Abgleich
45
Reinigung
47
Rücksendung
49
Battery and Battery Pack 1
53
Battery and Battery Pack
59
Battery on the CPU Module
59
General
59
Replacing the Battery
59
Battery Pack on the Power Supply Module (Option)
65
General
65
Replacing the Battery Pack
66
Testing the Battery Pack
72
English
73
Fuse
73
General
73
Replacing the Miniature Fuse F1
74
Mass Storage
81
General
81
Opening the Device
82
Replacing the Mass Storage
86
Replacing a 2.5" Flash Disk with a 2.5" Flash Disk
86
Replacing a 2.5"Flash Disk with a DOM Flash Memory
90
Replacing a DOM Flash Memory with a DOM Flash Memory
92
Calibration
95
Cleaning
97
Return
99
Advertisement
Related Products
Siemens SIMEAS R
Siemens SIMEAS Q80
Siemens SIPROTEC 5
Siemens SIMEAS-T
Siemens SIMATIC NET SCALANCE X-300M
Siemens Simatic S7 Series
Siemens SIMATIC IFP Basic Series
Siemens SIMATIC NET RUGGEDCOM RS416
Siemens SIMOTION ET 200S
Siemens SIMATIC NET RUGGEDCOM i803
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL