Chapter 7 - Options
(5) Monitoring LEDs
* Group 1
OHT POWER RUN
* Group 2
RESET
POWER
RUN
OHT
OCT
* Group 3
POWER
RUN
OHT
OCT
FOT
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 morek@morek.eu
LED
OHT
When heat sink is overheated and the level exceeds its setting
(GREEN,
limit, overheat protection is activated and OHT LED is turned ON
LEFT)
after DBU' s signal is shut off.
POWER
POWER LED is turned ON upon inverter Power ON because
(RED)
normally it is connected to the inverter.
RUN
RUN LED is blinking while DBU is operating normally by motor
(GREEN,
regenerating energy.
RIGHT)
LED
Press this switch to release OCT FAULT status. Pressing this
RESET
turns the OCT LED off.
POWER
POWER LED is turned ON upon inverter Power ON because
(GREEN)
normally it is connected to the inverter.
RUN
RUN LED is blinking while DBU is operating normally by motor
(GREEN)
regenerating energy.
When heat sink is overheated and the level exceeds its setting
OHT (RED)
limit, overheat protection is activated and OHT LED is turned ON
after DBU' s signal is shut off.
Over current trip signal. When overcurrent is flowed to the iGBT,
OCT (RED)
protection function shuts off the operating signal and OCT LED is
tured ON.
LED
POWER
POWER LED is turned ON upon inverter Power ON because
(RED)
normally it is connected to the inverter.
RUN
RUN LED is blinking while DBU is operating normally by motor
(GREEN)
regenerating energy.
When heat sink is overheated and the level exceeds its setting
OHT
limit, overheat protection is activated and OHT LED is turned ON
(RED)
after DBU' s signal is shut off.
Over current trip signal. When overcurrent is flowed to the iGBT,
OCT
protection function shuts off the operating signal and OCT LED is
(RED)
tured ON.
FOT
FOT LED is turned ON when fuse is opened to shut the
(RED)
overcurrent during braking.
180
Description
Description
Description