Persistent Fc Id Configuration Guidelines; Configuring Persistent Fc Ids - Cisco Nexus 5000 Series Configuration Manual

Nx-os san
Hide thumbs Also See for Nexus 5000 Series:
Table of Contents

Advertisement

FC IDs
DETAILED STEPS
Command or Action
Step 1
configure terminal
Example:
switch# configure terminal
switch(config)#
Step 2
fcdomain fcid persistent vsan vsan-id
Example:
switch(config)# fcdomain fcid persistent vsan 78
Step 3
no fcdomain fcid persistent vsan vsan-id
Example:
switch(config)# no fcdomain fcid persistent vsan 33

Persistent FC ID Configuration Guidelines

When the persistent FC ID feature is enabled, you can enter the persistent FC ID submode and add static or
dynamic entries in the FC ID database. By default, all added entries are static. Persistent FC IDs are configured
on a per-VSAN basis.
When manually configuring a persistent FC ID, follow these requirements:
• Ensure that the persistent FC ID feature is enabled in the required VSAN.
• Ensure that the required VSAN is an active VSAN. Persistent FC IDs can only be configured on active
• Verify that the domain part of the FC ID is the same as the runtime domain ID in the required VSAN.
• Verify that the port field of the FC ID is 0 (zero) when configuring an area.

Configuring Persistent FC IDs

You can configure persistent FC IDs.
SUMMARY STEPS
1. configure terminal
2. fcdomain fcid database
3. vsan vsan-id wwn 33:e8:00:05:30:00:16:df fcid fcid
4. vsan vsan-id wwn 11:22:11:22:33:44:33:44 fcid fcid dynamic
5. vsan vsan-id wwn 11:22:11:22:33:44:33:44 fcid fcid area
Cisco Nexus 5000 Series NX-OS SAN Switching Configuration Guide, Release 5.2(1)N1(1)
48
VSANs.
If the software detects a domain mismatch, the command is rejected.
Configuring Fibre Channel Domain Parameters
Purpose
Enters global configuration mode.
Activates (default) persistency of FC IDs in the
specified VSAN.
Disables the FC ID persistency feature in the
specified VSAN.
OL-27583-01