When adjusting the laser line appears on the left
side of the saw blade
1
1. Screw to change the movable range of the adjusting
screw
2. Adjusting screw
3. Hex wrench
4. Laser line
5. Saw blade
009514
When adjusting the laser line appears on the right
side of the saw blade
1. Adjusting screw
2. Saw blade
3. Laser line
009515
For both adjustments, do as follows.
1.
Make sure that the tool is unplugged.
2.
Draw the cutting line on the workpiece and place it
on the turn table. At this time, do not secure the
workpiece with a vise or similar securing device.
3.
Lower the blade by lowering the handle and just
check to see where the cutting line and the
position of the saw blade is. (Decide which
position to cut on the line of cut.)
4.
After decision the position to be cut, return the
handle to the original position. Secure the
workpiece with the vertical vise without shifting
the workpiece from the pre-checked position.
5.
Plug the tool and turn on the laser switch.
6.
Adjust the position of laser line as follows.
The position of laser line can be changed as the
movable range of the adjusting screw for the laser is
changed by turning two screws with a hex wrench. (The
movable range of laser line is factory adjusted within 1
mm from the side surface of blade.)
To shift the laser line movable range further away from
the side surface of blade, turn the two screws
counterclockwise after loosening the adjusting screw.
Turn these two screws clockwise to shift it closer to the
4
2
3
2
1
side surface of the blade after loosening the adjusting
screw.
Refer to the section titled "Laser line action" and adjust
the adjusting screw so that the cutting line on your
5
workpiece is aligned with the laser line.
NOTE:
Check the position of laser line regularly for
accuracy .
Have the tool repaired by Makita authorized
service center for any failure on the laser unit.
Cleaning of the lens for the laser light
For model LS1016L only
Fig.62
If the lens for the laser light becomes dirty, or sawdust
adheres to it in such a way that the laser line is no longer
easily visible, unplug the saw and remove and clean the
lens for the laser light carefully with a damp, soft cloth.
Do not use solvents or any petroleum-based cleaners on
the lens.
Fig.63
3
To remove the lens for the laser light, remove the saw
blade before removing the lens according to the
instructions in the section titled "Installing or removing
saw blade".
Loosen but do not remove the screw which secures the
lens using a screwdriver.
Pull out the lens as shown in the figure.
NOTE:
If the lens does not come out, loosen the screw
further and pull out the lens again without removing
the screw.
Replacing carbon brushes
Fig.64
Remove and check the carbon brushes regularly.
Replace when they wear down to the limit mark. Keep
the carbon brushes clean and free to slip in the holders.
Both carbon brushes should be replaced at the same
time. Use only identical carbon brushes.
Fig.65
Use a screwdriver to remove the brush holder caps.
Take out the worn carbon brushes, insert the new ones
and secure the brush holder caps.
After replacing brushes, plug in the tool and break in
brushes by running tool with no load for about 10
minutes. Then check the tool while running and electric
brake operation when releasing the switch trigger. If
electric brake is not working well, ask your local Makita
service center for repair.