hit counter script
Siemens SIMATIC IPC327G Operating Instructions Manual

Siemens SIMATIC IPC327G Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC327G:
Table of Contents

Advertisement

Quick Links

SIMATIC IPC327G
SIMATIC
Industrial PC
SIMATIC IPC327G
Operating Instructions
09/2021
A5E51366275-AA
Preface
Overview
Safety instructions
Installing and connecting
the device
Commissioning the device
and device functions
Expanding and assigning
parameters to the device
Maintaining and repairing
the device
Technical specifications
Technical support
Markings and symbols
List of abbreviations
1
2
3
4
5
6
7
A
B
C

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC IPC327G

  • Page 1 SIMATIC IPC327G Preface Overview SIMATIC Safety instructions Installing and connecting the device Industrial PC SIMATIC IPC327G Commissioning the device and device functions Expanding and assigning parameters to the device Operating Instructions Maintaining and repairing the device Technical specifications Technical support...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    USB stick in PDF format (in multiple languages). Conventions The terms "PC" and "device" are sometimes used to refer to the SIMATIC IPC327G in this documentation. Instead of the specific names of the operating system, we are using the abbreviation "Windows 10"...
  • Page 4 Preface History The following editions of these operating instructions have been published: Edition Comment 09/2021 First edition SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 5: Table Of Contents

    Commissioning the device and device functions ................31 General information on commissioning ................31 Switching the device on/off ....................31 Expanding and assigning parameters to the device ................33 Open the device ........................ 33 Installing the M.2 Module ....................34 SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 6 Overview of the internal module registers ................72 7.5.5.2 Watchdog control register ....................72 7.5.5.3 Watchdog counter register ....................73 7.5.5.4 Watchdog state register ..................... 73 7.5.5.5 Battery status register ......................73 BIOS description ........................ 74 SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 7 Markings and symbols ......................... 80 Overview ........................... 80 Safety ..........................80 Operator controls....................... 80 Certificates, approvals and markings .................. 81 Interfaces .......................... 82 List of abbreviations ..........................83 Abbreviations ........................83 Glossary ............................... 86 Index ..............................94 SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 8: Overview

    Overview Product description 1.1.1 Overview SIMATIC IPC327G provides high-level industrial functionality: • Compact design • Scalability • High degree of ruggedness • Various interfaces • Maintenance-free operation possibility SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 9: Configuration Plan

    Keyboard, mouse Connection through USB port Audio (optional) Connection for analog audio source and speaker Operating systems Operation Systems • Without OS • Windows 10 Enterprise 2019 LTSC (Long Term Servicing Channel) 64-bit (MUI) SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 10: Structure Of The Devices

    Front view and side view The front view on the left is the standard mounting position. The side view is on the right. ① Cooling fins ② LED displays ③ Mounting holes for wall mounting SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 11: Interfaces Of The Device

    COM (Optional) 2 × Serial interface, 9-pin RS232 D-sub connector ⑧ COM (X30/X31) 2 × Serial interface, 9-pin RS232/RS422/RS485 D-sub connector ⑨ Function earth Connection for function earth ⑩ On/Off switch Switch on; Switch off SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 12: Status Displays

    Flashing red (1 Hz) Watchdog is active Not accessing data Green flashing Accessing data Example programs for controlling the LEDs on Windows operating systems are available on the Siemens Industry Automation and Drive Technology (https://support.industry.siemens.com/cs/us/en/) SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 13: Accessories

    Overview 1.3 Accessories Accessories Accessories from Siemens are available for your device. These are not included in the scope of delivery. Additional accessories can be found on the Internet: • Industry Mall (https://mall.industry.siemens.com) • Expansion components and accessories (https://w3.siemens.com/mcms/pc-based- automation/en/industrial-pc/expansion_components_accessories)
  • Page 14: Safety Instructions

    The installation of expansions can damage the device, machine or plant. Device and system expansions can violate safety rules and regulations regarding radio interference suppression. If you install or exchange system expansions and damage your device, the warranty becomes void. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 15 • Replace the lithium battery only with an identical battery or types recommended by SIEMENS (article number: A5E48370874). • For any requirements on product maintenance, contact Siemens Service and support (Page 77). • Do not throw lithium batteries into fire, do not solder on the cell body, do not recharge, do not open, do not short-circuit, do not reverse polarity, do not heat above 100°C and...
  • Page 16: Security Information

    In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks.
  • Page 17: Data Protection

    Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
  • Page 18: Installing And Connecting The Device

    A damaged packaging indicates that ambient conditions have already had an impact on the device. The device might be damaged. Do not dispose of the original packaging. Pack the device during transportation and storage. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 19 7. Keep the enclosed documentation in a safe place. You need the documentation when you commission the device for the first time or meet other problems in the later work. 8. Record the identification data of the device. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 20: Identification Data Of The Device

    Product label Ethernet address 2 (MAC) Product label The following image shows the product label on the SIMATIC IPC327G as an example. COA label Microsoft Windows "Product Key" on the "Certificate Of Authenticity" (COA): The COA label is only attached to the rear of the device containing a preinstalled and activated Windows operating system.
  • Page 21: Permitted Mounting Positions

    • Install the device only as one of the described permitted mounting positions. • For installation of control cabinet, observe the country-specific regulations. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 22 If the mounting surface for wall and vertical mounting does not have sufficient load carrying capability, the device may fall down and be damaged. Ensure that the mounting surface on the wall can bear four times the total weight of the device, including fixing elements. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 23: Mounting On A Standard Rail

    Mounting on a standard rail Mounting on a standard rail is suitable for horizontal mounting of the device. Requirements • A SIEMENS 35 mm standard rail TH35-15 conforming to EN 60715:2001 The standard rail is mounted. • A standard rail bracket The standard rail bracket and two screws are included in the order variant "Standard rail...
  • Page 24: Wall Mounting

    2. Swing the device out of the rails. 3. Remove the rail from the device. 3.2.3 Wall mounting Wall mounting is one of the horizontal mounting types. Requirements • A screwdriver • Four anchors and four M4 screws SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 25: Connecting The Device

    • Disconnect the device from the power supply in good time when a thunderstorm is approaching. • Do not touch mains cables and data transmission cables during a thunderstorm. • Keep a sufficient distance from electric cables, distributors, and systems. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 26: Connecting The Function Earth

    The function earth also improves the discharge of interference generated by external power cables, signal cables or cables for I/O modules to ground. The connection for the function earth is labeled with the following symbol: SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 27 Firmly attach the cable lug to the function earth connection on the device using the M4 thread (see part labeled). Connect the function earth to the function earth connection of the cabinet or the plant in which the device is installed. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 28: Connecting The Power Supply

    • A two-core cable meet the following requirements: – a copper (Cu) cable cross-section of 0.75 mm to 2.5 mm – rated temperature 75 °C • Tightening torque: 0.56 Nm. • A slotted screwdriver with approximate 3 mm blade. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 29: Connect Device To Networks

    You can use the integrated Ethernet interfaces (10/100/1000 Mbps) for communication and data exchange with automation devices, for example SIMATIC S7. You need a suitable software to use this functionality: STEP 7, WinCC, SIMATIC NET. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 30 Control level. Information on this can be found on the SIMATIC NET Manual Collection CD. The software package and the documentation are not included in the product package. Additional information You can find additional information in Technical support. (Page 77) SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 31: Commissioning The Device And Device Functions

    The commissioning procedure in this chapter is only applicable to the IPCs with operating system. For the configurations without operating system pre-installed, contact the operating system provider to install the operating system first. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 32 Procedure - Switching off the device To turn off the device, always select the function "Start" > "Shut down". Additional information Information on your operating system can be found on the Internet: • Microsoft® Windows® 10 (https://support.industry.siemens.com/cs/ww/en/view/109749498) SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 33: Expanding And Assigning Parameters To The Device

    Remove the marked four screws on the rear panel of the device. Lift up the device's rear panel. Procedure - closing the device To close the device, carry out the steps for opening the device in the reverse order. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 34: Installing The M.2 Module

    Installing the M.2 Module Introduction to the M.2 Module Siemens uses the M.2 Module to extend the Siemens IPC. It can be produced by Siemens or other third-party suppliers. Our device provides one or several M.2 Key B interfaces and mounting positions.
  • Page 35 You can install 4G/5G SIM card through SIM card slot to connect to network. But SIM card function has not been certified in both ordinary location and hazardous location. Requirements • The device is opened. • A T8 screwdriver SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 36 Note: Make sure the M.2 Module board is located be- tween head and spacer of assembly screw. If the M.2 Module has a cable with an additional interface-card connected to the housing opening, you need to do the following procedures: SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 37: Installing And Removing M.2 Nvme/ Sata Ssd

    Installing and removing M.2 NVMe/ SATA SSD Requirements • The device is disconnected from the power supply. • The device is opened. • A M.2 NVMe/SATA SSD that is approved for industrial applications. • A T10 screwdriver SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 38 Procedure - removing the M.2 NVMe/SATA SSD To remove the M.2 NVMe/SATA SSD, carry out the steps for installing the M.2 NVMe/SATA SSD in the reverse order. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 39: Maintaining And Repairing The Device

    Maintaining and repairing the device Maintenance intervals To maintain high system availability, Siemens recommends you replace some of the PC components that subject to wear in according with the replacement intervals indicated in the table below. Component Replacement interval: CMOS backup battery...
  • Page 40 • T20 screwdriver for function earth connection • T8 screwdriver for spring screw and M.2 Module on the motherboard • T10 screwdriver for all the remaining screws SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 41: Installing And Removing Hardware

    – Rated voltage: 3 V DC – Max abnormal charging current: 10 mA • For any requirements on product maintenance, contact Siemens Technical support (Page 77). • Do not throw lithium batteries into fire, do not solder on the cell body, do not recharge, do not open, do not short-circuit, do not reverse polarity, do not heat above 100°C and...
  • Page 42 – Courant de charge anormal max. : 10 mA • Pour toute demande concernant la maintenance du produit, contactez le support technique (Page 77) Siemens. • Ne jetez pas au feu des piles au lithium, n'effectuez pas de soudage sur la pile, ne la rechargez pas, ne l'ouvrez pas, ne la court-circuitez pas, n'intervertissez pas les pôles, ne...
  • Page 43: Replacing The Memory Module

    DDR4 up to 3200MT/S SODIMM 260pin Requirements • The device is disconnected from the power supply. • All connecting cables on the device are unplugged. • The device is opened. • T8, T10 and T20 screwdrivers SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 44 ESD directives on handling electrostatic sensitive components. Note Siemens strongly recommends that you use only memory modules approved by Siemens. Siemens disclaims any liability for impairment of functions caused by the use of third-party memory modules. Procedure-Removing the memory module CAUTION •...
  • Page 45 Unscrew the marked four screws with a T10 screwdriver on the motherboard, then take out the whole motherboard. Press the retaining clips outward in the direction of the arrows to unlock the memory socket. Pull out the memory module from the socket. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 46: Reinstalling The Operating System

    • Windows 10 operating system is installed in your IPC. • You need to connect a mouse, a monitor and a keyboard to your PC. • You also need the supplied USB stick to your PC. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 47 4. Click Accept to accept the license agreement. 5. Click Install to allow the computer to start the installation. The installation starts. 6. Click Yes to confirm the user account control question. 7. Click Finish. The installation is completed. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 48 3. Click Yes to confirm the user account control question. 4. Click Next to continue. 5. Click Yes to accept license agreement. 6. Click Next to confirm the Readme File Information and move on. The installation starts. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 49: Recycling And Disposal

    Recycling and disposal Due to their low level of pollutants, the devices described in these operating instructions can be recycled. Contact a certified disposal service company for environmentally sound recycling and disposal of your old devices. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 50: Technical Specifications

    The following shows the approvals that may be available. For the device itself, it is certificated as shown on the product label and package label. ISO 9001 certificate The Siemens quality management system for all production processes (Development, Production, Sales and Service of Automation Products, -Systems and -Solutions) meets the requirements of ISO 9001:2015 Certificate registration no.
  • Page 51 Avis Canadian Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. Responsible party for Supplier's Declaration of Conformity Siemens Industry, Inc. Digital Factory - Factory Automation 5300 Triangle Parkway, Suite 100 Norcross, GA 30092 Mail to: (amps.automation@siemens.com)
  • Page 52 This product meets the requirements of Korean certification. This product satisfies the requirement of the Korean Certification (KC Mark). 이 기기는 업무용(A 급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 53 Responsible party for Supplier's Declaration of Conformity 西門子股份有限公司 臺北市11503南港區園區街3號8樓 電子郵件信箱: (Adscs.taiwan@siemens.com) UKCA This product meets the requirements of UKCA. WEEE label (European Union) Disposal instructions, observe the local regulations and the section "Recycling and disposal (Page 49) ". SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 54: Directives And Declarations

    The following abbreviations are commonly used for electrostatic sensitive devices: • ESD – Electrostatic sensitive device • ESD – Electrostatic Sensitive Device as a common international designation Electrostatic sensitive devices can be labeled with an appropriate symbol. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 55 The figure shows the maximum electrostatic voltages with which a person is charged, depending on humidity and material. These values conform to the specifications of IEC 61000-4-2. ① Synthetic materials ② Wool ③ Antistatic materials such as wood or concrete SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 56 This way, the discharge energy does not reach and damage the sensitive components. – Discharge your body electrostatically by touching grounded metallic parts before you take a measurement at a module. Always use grounded measuring instruments. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 57: Dimension Drawings

    Technical specifications 7.3 Dimension drawings Dimension drawings 7.3.1 Dimension drawing of device Wall mounting all dimensions in mm SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 58 Technical specifications 7.3 Dimension drawings Mounting on a standard rail all dimensions in mm SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 59: Technical Data

    ± 2 kV (5 kHz /100 kHz) in accordance with IEC 61000-4-4; ed interference on the supply lines Burst • ± 1kV line to line, ±2 kV line to earth in accordance with IEC 61000-4-5; Surge SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 60 4G DDR4 SDRAM • 8G DDR4 SDRAM • 16G DDR4 SDRAM The max speed of memory is up to 3200 MT/s. The memory module supports IBECC function, and its default value in BIOS is "Disable". SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 61 Connection of a DP monitor Keyboard, mouse Connection via USB port Audio (optional) Connection for analog audio source and speaker In BIOS Setup, you can configure support for RS232/RS422/RS485 for COM1 and COM2 ports. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 62: Ambient Conditions

    Vibration resistance, tested in accordance with IEC 60068-2-6 Operation Except DIN-Rail: • 5 to 8.4 Hz: 3.5 mm • 8.4 to 500 Hz: 9.8 m/s² DIN-Rail: • 10 to 58 Hz: 0.0375 mm • 58 to 200 Hz: 4.9 m/s² SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 63: Power Demand Of The Components

    2.5 A at 24 V Buffering upon power failure Hold-up time > 20 ms (after > 5 ms, DC_FAIL becomes active) Protection class Class III (A function earth must be connected to the device) SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 64: Hardware Descriptions

    Intel Atom® x6413E Processor (up to 3.0 GHz) Memory DDR4 SDRAM Memory expansion up to 16 GB with the following memory modules: • 4G DDR4 SDRAM • 8G DDR4 SDRAM • 16G DDR4 SDRAM Graphics Integrated • Intel® UHD Graphics graphics SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 65: External Interfaces

    Input / output Data channel USB2 Input / output Ground – Data channel USB3 Input Data channel USB3 Input Ground – Data channel USB3 Output Data channel USB3 Output 7.5.2.3 DC in connector Short description +24V SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 66: Ethernet Port

    Input/output ML_Lane 0+ DP data 0+ Output Ground ML_Lane 0+ DP data 0+ Output ML_Lane 1+ DP data 1+ Output Ground ML_Lane 1- DP data 1- Output ML_Lane 2+ DP data 2+ Output Ground SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 67: Serial Interface

    Pin assignment RS232 Short description Meaning Data carrier detect (I) Received data (I) Transmitted data (O) Data terminal ready (O) Ground Data set ready (I) Request to send (O) Clear to send (I) Incoming call (I) SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 68: Internal Interfaces

    2 × USB 2.0 pin header Internal • PCIe × 2 lane + USB 2.0 USB dongle Internal • 1 × USB 2.0 type A connector SIM card slot Internal • 1 × SIM card slot SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 69: M.2 Interface

    UIM-CLK PERp1 UIM-RESET PERn1 CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B USB_D- W_DISABLE# USB_D+ WWAN_PWR_OFF_N 3.3V 3.3V SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 70 DEVSLP PETp1 PETn1 PERp1 PERn1 CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B CONNECTOR KEY B USB_D- W_DISABLE# USB_D+ 3.3V 3.3V SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 71: Usb 2.0 Pin Header

    Windows operating system, depending on the hardware equipment, drivers and connected external devices. You can view the current allocation of system resources or possible conflicts in the Control Panel. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 72: Input/Output Address Areas

    SIO logic device 8 CR F2h Watchdog state register (Page 73) SIO logic device 7 CR FDh Battery status register (Page 73) For more information and reference code for accessing to Super IO, contact Siemens Technical support. 7.5.5.2 Watchdog control register...
  • Page 73: Watchdog Counter Register

    Meaning of the bits Battery status register (read-only, address 404Dh) Meaning CMOS battery capacity is still sufficient. CMOS battery capacity is exhausted (remaining capacity is suffi- cient for approx. one month) CMOS battery is empty SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 74: Bios Description

    Setup parameters may not be included, depending on your order. The interface of your BIOS Setup can deviate from the figures in this document. You can find a detailed description on Firmware/BIOS description (SIMATIC IPC227G, IPC277G, IPC327G, IPC377G) Operating Instructions (https://support.industry.siemens.com/cs/ww/en/view/109797240). SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 75: Bios Update

    If you have purchased a new BIOS update for your device, follow these steps to install the update: 1. Connect the device to the power supply. 2. Take the BIOS update you downloaded from the Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/view/75842768)page and place it on the USB stick.
  • Page 76: Alarm, Error And System Messages

    Check the CMOS clock. Keyboard error • Field PG: Internal keyboard defective and no external keyboard connected • Other devices: Keyboard defective or not connected SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 77: Technical Support

    You can find additional information and support for the products described on the Internet at the following addresses: • Technical support (https://support.industry.siemens.com/cs/ww/en/) • Support request form (https://support.industry.siemens.com/My/ww/en/requests#createRequest) • After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) • SIMATIC Documentation Collection (http://www.siemens.com/simatic-tech-doku-portal) • Your local representative (http://w3.siemens.com/aspa_app/) • Training center (https://www.sitrain-learning.siemens.com/PLG/?AppLang=en) • Industry Mall (https://mall.industry.siemens.com)
  • Page 78: Troubleshooting

    You need to install the USB device drivers for the supported. required operating system. The pop-up message "Win- The M.2 NVMe/SATA SSD card is Press Enter to continue the boot. dows boot manager failed" changed to another boot device. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 79: Notes On The Use Of Third-Party Modules

    If the error no longer occurs, the third-party module be- • Different pin assignment ing used was the cause of the fault. Replace the third-party module with a Siemens module or contact the module sup- plier. If the device still crashes, contact your technical support team. •...
  • Page 80: Markings And Symbols

    Opening for Kensington lock opening Attention ESD (Electrostatic sensitive Warning of hot surface device) Operator controls Symbol Meaning Symbol Meaning On/off switch, without electrical isola- Eject CD/DVD tion On/off switch, without electrical isola- tion SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 81: Certificates, Approvals And Markings

    CE markings for European countries Marking of Federal Communications Commission for the USA EFUP (Environment Friendly Use Peri- Approved for Korea od) marking for China Test mark of the Underwriters Labora- Disposal information, observe the tories local regulations. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 82: Interfaces

    DVI-D interface Line In LAN interface, not approved for con- Line Out necting WAN or telephone Serial port Microphone input USB port Universal Audio Jack USB 2.0 high-speed port Headphone output USB 3.0 super-speed port SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 83: List Of Abbreviations

    Disk Operating System DisplayPort Deutsche Gesellschaft zur Zer- tifizierung von Qualitätsman- agement mBH Data Set Ready Ready for operation Data Terminal Ready Data terminal is ready Digital Versatile Disk Components sensitive to electro- static charge SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 84 NVMe Non-Volatile Memory Express NVRAM Non Volatile Random Access Non-volatile data memory. Data memory is re- Memory tained without external power supply. Optical Disk Drive Personal computer Peripheral Component Intercon- High-speed expansion bus nect SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 85 Intel technology which provides a virtual, closed environment. VT-d Virtualization Technology for Enables the direct assignment of a device (e.g. Directed I/O network adapter) to a virtual device. Watchdog Program monitoring with error detection and alarming. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 86: Glossary

    Communauté Européene: The CE symbol confirms the conformity of the product with all applicable EC directives such as the EMC Directive. Chipset Located on the motherboard, connects the processor with the PCI or PCIe bus and the external interfaces. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 87 TVs to computers, DVD players and similar devices. Drivers Program parts of the operating system. They adapt user program data to the specific formats required by I/O devices such as hard disk, printers, and monitors. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 88 10/100/1000 Mbps. Execute Disable Capability Hardware implementation that prevents mutual memory accesses by programs and applications. It is only effective when all relevant system components, such as processors, operating systems and applications are supported. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 89 Intel Active Management Technology This technology permits diagnostics, management and remote control of PCs. It is only effective when all relevant system components, such as processors, operating systems and applications are supported. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 90 Conventional drives can be used as USB devices. License key The license key represents the electronic license stamp of a license. Siemens AG issues a license key for each software that is protected by a license. License key USB flash drive The license key USB flash drive contains the authorizations or license keys required to enable protected SIMATIC software.
  • Page 91 Industrial Ethernet meets the requirements of industrial automation technology. Programmable controller The programmable controllers of the SIMATIC S7 system consist of a central controller, one or more CPUs, and various other modules (e.g. I/O modules). SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 92 This design makes SSDs more rugged, provides shorter access times, low energy consumption and rapid data transfer. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 93 Wake on Local area network. This function allows the PC to be started via the LAN interface. Warm restart The restart of a computer after a program was aborted. The operating system is loaded and restarted again. The CTRL+ ALT+ DEL hotkey can be used to initiate a warm restart. SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 94: Index

    DC power supply, 63 Degree of protection, 59 Device Korea Certificate, 52 Closing, 33 Open, 33 Directive ESD Directive, 54 Limitation of liability, 40 DisplayPort interface, 66 Lithium battery, 41 Drive, 61 EAC, 52 SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...
  • Page 95 DC power supply, 63 Processor, 60 Product label, 20 Wall mounting, 24, 57 PROFINET, 30, 64 Warranty, 14 Protection class, 59 Weight, 59 Protective measure Static electricity, 56 Radiation, 16 High frequency radiation, 16 SIMATIC IPC327G Operating Instructions, 09/2021, A5E51366275-AA...

This manual is also suitable for:

Simatic ipc377g

Table of Contents