Aotewell Ltd www.aotewell.com Industry Automation Introduction ______________ SIMATIC Industrial PC SIMATIC Rack PC 647B ______________ Description ______________ Application planning SIMATIC ______________ Installation Industrial PC ______________ SIMATIC Rack PC 647B Connecting ______________ Commissioning Getting Started ______________ Troubleshooting ______________ Dimension drawings ______________ Appendix 12/2008 A5E02147333-01...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Aotewell Ltd www.aotewell.com Industry Automation Table of contents Introduction..............................5 Description..............................7 External design ..........................7 Operator Controls ..........................8 Connecting elements ........................9 Status displays ..........................11 Application planning..........................15 Transport............................15 Unpacking and checking the delivery unit ...................16 Ambient and environmental conditions..................18 Access protection.........................18 Installation ...............................
Page 4
Aotewell Ltd www.aotewell.com Industry Automation Table of contents SIMATIC Rack PC 647B Getting Started, 12/2008, A5E02147333-01 HongKong|UK|China sales@aotewell.com +86-755-8660-6182...
Aotewell Ltd www.aotewell.com Industry Automation Introduction Objective of this documentation This Getting Started documentation contains all the information you need for commissioning and using the SIMATIC Rack PC 647B. Scope of validity of this document This documentation is valid for all variations of SIMATIC Box PC 647B and describes delivery conditions as of December 2008.
Page 6
Aotewell Ltd www.aotewell.com Industry Automation Introduction SIMATIC Rack PC 647B Getting Started, 12/2008, A5E02147333-01 HongKong|UK|China sales@aotewell.com +86-755-8660-6182...
Aotewell Ltd www.aotewell.com Industry Automation Description External design Front view of the device (example) ① Front panel with vent openings (filter mat and fan behind the front panel). Check the filter mat regularly for soiling and, if appropriate, replace it. ②...
Aotewell Ltd www.aotewell.com Industry Automation Description 2.2 Operator Controls Operator Controls Control elements, On/Off and Reset buttons ① On/off button For switching the device on or off ② Reset button The reset button can be operated using a pointed object or a paper clip, for example. The button signal triggers a hardware reset.
Aotewell Ltd www.aotewell.com Industry Automation Description 2.3 Connecting elements Connecting elements Layout of the interfaces on the rear of the device Item Designation Description ① DVI or DVI-D connector of the ADD2 card for digital monitors (optional) or DMS59 DMS59 connector for Dual Head graphics card (optional). ②...
Page 10
Aotewell Ltd www.aotewell.com Industry Automation Description 2.3 Connecting elements Item Designation Description ⑫ VGA connection (adapter plugged in) (via the graphics card) ⑬ DVI-I DVI-I connection (via the graphics card) ⑭ Dual-head adapter (via DMS59 connector on dual-head graphics card (optional) the graphics card) Power supply Position of the IEC connector...
Aotewell Ltd www.aotewell.com Industry Automation Description 2.4 Status displays Status displays Front status displays Display Meaning LEDs Description POWER PC status display Isolated from mains YELLOW Standby (hibernating) GREEN PC in operation Display for hard disk No access access GREEN Access No connection ETHERNET 1 *...
Page 12
Aotewell Ltd www.aotewell.com Industry Automation Description 2.4 Status displays Front status displays SF PROFINET Status display for CP not available • (optional) CP 1616 onboard CP disabled • No error, communication • established Charging in progress • CP 1616 driver not installed •...
Page 13
Aotewell Ltd www.aotewell.com Industry Automation Description 2.4 Status displays Rear status displays Display Meaning Description No cable connected Ethernet LAN 1, 2 * Green LED • Link status display Cable disabled • Interface disabled • GREEN Active cable connected No cable connected Yellow LED •...
Page 14
Aotewell Ltd www.aotewell.com Industry Automation Description 2.4 Status displays SIMATIC Rack PC 647B Getting Started, 12/2008, A5E02147333-01 HongKong|UK|China sales@aotewell.com +86-755-8660-6182...
Aotewell Ltd www.aotewell.com Industry Automation Application planning Transport Despite the device's rugged design, its internal components are sensitive to severe vibrations or shock. You must therefore protect the PC from severe mechanical stress when transporting it. You should always use the original packaging for shipping and transporting the device. CAUTION Risk of damage to the device! When transporting the PC in cold weather, it may be submitted to extreme variations in...
● Verify that the shipment contains the complete unit and your separately ordered accessories. Please inform your local dealer of any disagreements or transport damage. ● Please inform Siemens AG by means of the enclosed SIMATIC IPC/PG quality control report form.
Page 17
Aotewell Ltd www.aotewell.com Industry Automation Application planning 3.2 Unpacking and checking the delivery unit ● Microsoft Windows "Product Key" on the "Certificate of Authenticity" (COA). The COA label is attached to the inside of the front door. You may need the Product Key in case you reinstall the operating system. Figure 3-2 COA label Serial number...
Aotewell Ltd www.aotewell.com Industry Automation Application planning 3.3 Ambient and environmental conditions Ambient and environmental conditions When you plan your project, you should make allowances for: ● Observe the climatic and mechanical environmental conditions in the technical data in your operating instructions. ●...
Aotewell Ltd www.aotewell.com Industry Automation Installation Installing the device Optional installation locations The device can be installed horizontally in control desks, in switch cabinets and in 19-inch rack systems. Optional mounting methods Options of mounting the device ● Mounting on cabinet brackets ●...
Aotewell Ltd www.aotewell.com Industry Automation Installation 4.2 Technical data of the telescopic rails Technical data of the telescopic rails Ultimate load per pair At least 14 kg Full extraction length At least 470 mm Rail thickness Maximum 9.7 mm Mounting screws M5 x 6 mm SIMATIC Rack PC 647B Getting Started, 12/2008, A5E02147333-01...
Aotewell Ltd www.aotewell.com Industry Automation Connecting Connecting peripherals Note before connecting NOTICE Connect only peripherals approved for industrial applications according to EN 61000-6-2. Note Hot-plug I/O modules (USB) may be connected while the PC is in operation. CAUTION I/O devices that are incapable of hot-plugging may only be connected after the device has been disconnected from the power supply.
Aotewell Ltd www.aotewell.com Industry Automation Connecting 5.2 Connecting the device to power Connecting the device to power Note before connecting Note The wide-range power supply module is designed for operation on 100 VAC to 240 VAC mains. The setting of the voltage range takes place automatically. WARNING Do not connect or disconnect power and data cables during thunderstorms.
Page 23
Aotewell Ltd www.aotewell.com Industry Automation Connecting 5.2 Connecting the device to power Localized information Outside of the USA and Canada, operation on a 230 V power supply: This device is equipped with a safety-tested power cord which may only be connected to a grounded shockproof power outlet.
Page 24
Aotewell Ltd www.aotewell.com Industry Automation Connecting 5.2 Connecting the device to power Secure the power plug You can secure the power plug in order to avoid unintentional disconnection of the power cord. Steps for securing the power plug 1. Loosen the screw ② on the power supply unit.
Aotewell Ltd www.aotewell.com Industry Automation Connecting 5.3 Equipotential bonding Equipotential bonding A low-impedance ground connection improves the discharge of interference generated by external power cables, signal cables or cables for I/O modules to ground. Equipotential bonding terminal The equipotential bonding terminal ① on the device (large surface, large-area contact) must be connected with the central grounding busbar of the cabinet or plant in which the PC is to be installed.
Aotewell Ltd www.aotewell.com Industry Automation Commissioning Requirements for commissioning ● Before you switch on the device, you should verify that all peripheral devices such the keyboard, mouse, monitor and the power supply are connected. ● The operating system of your device is preinstalled on the hard disk. CAUTION Risk of damage to the device! Make sufficient allowances for the device to acquire room temperature before you put it...
Aotewell Ltd www.aotewell.com Industry Automation Commissioning 6.3 Reinstalling the software Switching off the device Note On a Windows platform, always shut down the PC by clicking Start > Close. Press the on/off button behind the front panel door. The green power LED is switched off. Disconnect the mains connector to isolate the device from mains.
Aotewell Ltd www.aotewell.com Industry Automation Troubleshooting General problems This chapter provides you with tips on how to localize and troubleshoot frequently occurring problems. Problem Possible cause To correct or avoid error The device is not operational No power supply Check the power supply, and the power cord / connector Check the environment conditions Device operation is non-compliant...
Page 30
Aotewell Ltd www.aotewell.com Industry Automation Troubleshooting 7.1 General problems Problem Possible cause To correct or avoid error Although the BIOS setting is The backup battery is low. Contact Technical Support. OK, the time and data are still incorrect. USB device not responding. The USB ports are disabled in Use a different USB port or enable the port.
Page 31
Aotewell Ltd www.aotewell.com Industry Automation Troubleshooting 7.1 General problems Error displays on the front panel Front LED Possible cause For details about the error display, see the operating instructions: Red WATCHDOG LED is lit Watchdog has triggered Section "Watchdog (WD)" Red TEMP LED is lit Excess temperature in the device Section "Temperature monitoring / display...
Page 32
Aotewell Ltd www.aotewell.com Industry Automation Troubleshooting 7.1 General problems SIMATIC Rack PC 647B Getting Started, 12/2008, A5E02147333-01 HongKong|UK|China sales@aotewell.com +86-755-8660-6182...
Aotewell Ltd www.aotewell.com Industry Automation Dimension drawings 8.2 Dimensional drawing for the use of telescopic rails Dimensional drawing for the use of telescopic rails Below you will find the dimensions of the telescopic rails from the Rittal company: ● Type RP 3659.180 for 600 mm cabinet ●...
Aotewell Ltd www.aotewell.com Industry Automation Appendix Guidelines and Declarations Notes on CE marking The following applies to the SIMATIC product described in this documentation: EMC directive This product fulfills the requirements of EC directive 2004/108/EEC "Electromagnetic Compatibility", and is designed for operation in the following fields of application in accordance with this CE marking: Fields of application Requirements for...
A.2 Certificates and Approvals Certificates and Approvals ISO 9001 certificate The Siemens quality management system for all production processes (development, production and sales) meets ISO 9001:2000 requirements. This has been certified by DQS (the German society for the certification of quality management systems).
Page 37
Aotewell Ltd www.aotewell.com Industry Automation Appendix A.2 Certificates and Approvals CANADA Canadian Notice This Class B digital apparatus complies with Canadian ICES-003. Avis Canadian Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. SIMATIC Rack PC 647B Getting Started, 12/2008, A5E02147333-01 HongKong|UK|China sales@aotewell.com...
A.3 Service and support Service and support Local information Contain your Siemens representative (http://www.siemens.com/automation/partner) if you have questions about the products described here. Technical documentation for SIMATIC products You can find additional documentation for SIMATIC products and systems in the Internet: SIMATIC Guide manuals (http://www.siemens.com/simatic-tech-doku-portal)