Industrial Controls Block Library Motor Starter SIRIUS for SIMATIC PCS 7 SIRIUS Motor Starter PCS 7 Library V7.1+SP2 / SIRIUS Motor Starter PCS 7 Library V8 Migration 8.0+SP1 Getting Started Edition 08/2013 Answers for industry.
Page 3
___________________ SIRIUS Motor Starter Preface PCS 7 Library "V7.1+SP2"/ ___________________ First steps for the project "V8 Migration V8.0+SP1" ___________________ Creating CFC charts Industrial Controls ___________________ Upgrade to PCS7 V7.1 Motor starter ___________________ SIRIUS Motor Starter Configuration of a faceplate PCS 7 Library "V7.1+SP2" / Operating and monitoring the ___________________ "V8 Migration V8.0+SP1"...
Page 4
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Table of contents Preface ............................7 First steps for the project ......................11 Configuration of PC station ..................... 11 Configuring the device hardware .................... 14 Creating CFC charts ........................19 Upgrade to PCS7 V7.1 ......................... 23 Configuration of a faceplate ......................27 Operating and monitoring the process ....................
Page 6
Table of contents SIRIUS Motor Starter PCS 7 Library "V7.1+SP2"/ "V8 Migration V8.0+SP1" Getting Started, 08/2013, A5E02897539020A/RS-AA/005...
Preface Brief description The Getting Started of the PCS 7 library for SIRIUS motor starter uses a simple example project to show you the basic procedures: ● Basic configuration steps ● Handling and monitoring different signal blocks ● Parameterization This Getting Started serves as an introduction and largely dispenses with detailed information and background information.
Page 8
Preface Software required for the Getting Started of the PCS 7 block library for motor starters ● You can execute the example project on any PC or programming device on which the following software is installed: – Windows operating system –...
Page 9
SIMATIC S7-400, CPU 416-3 CENTRAL PROCESSING, e.g. with PROFIBUS DP interface 6ES7407-0KA01-0AA0 SIMATIC S7-400, Power Supply PS 407-10 A, UC 120 / 230 V, DC 5 V / 10 A Table 1- 3 Hardware - Automation station 2: Configuration following a Y-link...
First steps for the project Configuration of PC station S7 automation station or S7-PLCSIM - Requirement To be able to use the S7 automation station or S7-PLCSIM, you must set up a PROFIBUS interface for the SIMATIC PC station. This can be used to compile OS tags and establish the connection between the AS and the OS.
Page 12
First steps for the project 2.1 Configuration of PC station Procedure Table 2- 1 Steps Step Action Select the "Start > SIMATIC > SIMATIC Manager" menu command or double-click on the corresponding icon on • the desktop. The SIMATIC Manager starts. Select the SIMATIC PC station in the "Projects"...
Page 13
First steps for the project 2.1 Configuration of PC station Step Action Select SIMATIC Manager: "Options > Set PG/PC interface". The dialog box "Set PG/PC Interface" opens. Setting the PG/PC interface Select the option "PC internal (local)"as the "Interface Parameter Assignment Used" and click on "OK". The PG/PC interface is set to "PC internal (local)".
First steps for the project 2.2 Configuring the device hardware Configuring the device hardware Introduction The PCS 7 wizard has created the following components: ● A SIMATIC 400 station ● A SIMATIC PC station ● A master data library Now add additional hardware modules to the project from the Hardware Catalog in HW Config.
Page 15
First steps for the project 2.2 Configuring the device hardware Step Action If the hardware catalog is not visible, select the "View > Catalog" menu command. • Open the "PROFIBUS DP > ET 200S" folder in the standard hardware catalog. •...
Page 16
First steps for the project 2.2 Configuring the device hardware Step Action Compile the hardware configuration: "Station > Save and Compile". • Set the PG/PC interface to CP 5613 A2 (PROFIBUS) • Download the automation station configuration: "PLC Download". • SIRIUS Motor Starter PCS 7 Library "V7.1+SP2"/ "V8 Migration V8.0+SP1"...
Page 17
First steps for the project 2.2 Configuring the device hardware Procedure for device configuration with GSD file Table 2- 3 Steps for configuring following a Y-link/redundant H station Step Action Select the SIMATIC 400 station in the component view. • Select the "Edit >...
Page 18
First steps for the project 2.2 Configuring the device hardware SIRIUS Motor Starter PCS 7 Library "V7.1+SP2"/ "V8 Migration V8.0+SP1" Getting Started, 08/2013, A5E02897539020A/RS-AA/005...
Creating CFC charts Introduction Adapt the standard CFC charts of the "SIRIUS Motor Starter PCS 7 Block Library". The CFC charts are already prepared and archived as a ZIP file. If the CFC charts are not yet available, extract the ZIP files in SIMATIC Manager to the master library in the "S7 Program >...
Page 20
Creating CFC charts Step Action Compile the charts using the "Generate module driver" function. Compile program/download PLC Make the required interconnections of the blocks. You can find the description in: "SIRIUS Motor Starter PCS 7 Library V7.1+SP2" or "SIRIUS Motor Starter PCS 7Library V8 MigrationV8.0+SP1" > "Module drivers of motor starters"...
Page 21
Creating CFC charts Note Updating existing blocks If an older version of the blocks of the PCS 7 SIRIUS motor starter library was previously used in the project, this can then be updated. When the motor starter blocks are inserted, a dialog is displayed for updating the blocks.
Page 22
Creating CFC charts Select "Options > Block Types". Select the blocks of the PCS 7 SIRIUS Motor Starter Library in the offline block folder and import them into the chart folder using the button. SIRIUS Motor Starter PCS 7 Library "V7.1+SP2"/ "V8 Migration V8.0+SP1" Getting Started, 08/2013, A5E02897539020A/RS-AA/005...
Upgrade to PCS7 V7.1 Upgrade from PCS7 MS Library V7.0 SP1 / SP1+HF1 to SIRIUS MS PCS7 Library V7.1. NOTICE Damage to library When you upgrade, the blocks are not to be imported. Doing so will corrupt the library. If you delete all previous versions of the blocks and clean up the project (see step 3), it is not necessary to import the same block types.
Page 24
Upgrade to PCS7 V7.1 Step Action Delete all instances of the two blocks. • Select the menu command "Options > Block types" to clean up the project. • Block types Clean up Drag-and-drop the MS_DIR (FB 552) and MS_REV (FB 553) blocks from the SIRIUS MS PCS7LibV71 •...
Page 25
Upgrade to PCS7 V7.1 Step Action Open WinCC by right-clicking the OS station. WinCC Explorer opens. • Navigate to "OS Project Editor" and open it. • Confirm with OK to update the faceplates in the WinCC project. • If you have completed step 5, compile the OS again. •...
Page 26
Upgrade to PCS7 V7.1 SIRIUS Motor Starter PCS 7 Library "V7.1+SP2"/ "V8 Migration V8.0+SP1" Getting Started, 08/2013, A5E02897539020A/RS-AA/005...
Configuration of a faceplate Introduction The CFC charts are set up and interconnected. Compile the WinCC application OS for the blocks that have been configured in the CFC charts. Requirements ● The library and the faceplates of the PCS 7 Block Library for SIRIUS Motor Starter V7.1 must be installed.
Page 28
Configuration of a faceplate Procedure Table 5- 1 Steps Step Action Open the component view of the project "SIMATIC PC Station > WinCC Application > OS(1)". • Open the popup menu with a right click. Select the "Compile" menu command. •...
Page 29
Configuration of a faceplate Step Action Compiling of the OS begins. You see the following window during the process: Compile (Entire OS with memory reset) When compiling has been completed, the following information appears Compile OS - Compilation completed SIRIUS Motor Starter PCS 7 Library "V7.1+SP2"/ "V8 Migration V8.0+SP1" Getting Started, 08/2013, A5E02897539020A/RS-AA/005...
Page 30
Configuration of a faceplate Updating faceplates Note If an older version of the PCS 7 SIRIUS Motor Starter Library was previously used in the project, you can update the blocks. 1. Open the PCS 7 project in SIMATIC Manager. 2. Open WinCC by right-clicking the OS station. WinCC Explorer opens. 3.
Further information on performing an upgrade can be found in the "SIRIUS Motor Starter PCS 7 Library "V7.1+SP2"/ "V8 Migration V8.0+SP1"" Programming and Operating Manual on the Internet (http://support.automation.siemens.com/WW/view/en/41856573). SIRIUS Motor Starter PCS 7 Library "V7.1+SP2"/ "V8 Migration V8.0+SP1" Getting Started, 08/2013, A5E02897539020A/RS-AA/005...
Page 32
Operating and monitoring the process SIRIUS Motor Starter PCS 7 Library "V7.1+SP2"/ "V8 Migration V8.0+SP1" Getting Started, 08/2013, A5E02897539020A/RS-AA/005...
Abbreviations Abbreviations Abbreviation Meaning Automation station Continuous Function Chart Device master data Human Machine Interface HW Config "Hardware configuration" module in the SIMATIC Manager Operator Station PCS 7 Process Control System 7 Central Processor Unit Motor starter SIRIUS Motor Starter PCS 7 Library "V7.1+SP2"/ "V8 Migration V8.0+SP1" Getting Started, 08/2013, A5E02897539020A/RS-AA/005...