hit counter script
Siemens Mobilett Plus Installation Instructions Manual

Siemens Mobilett Plus Installation Instructions Manual

Hide thumbs Also See for Mobilett Plus:

Advertisement

Quick Links

Mobilett Plus/ E/ M/ HP
Service
Installation Instructions
Installation of remote exposure switch system
Print No.: SPR8-220.031.02.02.02
Replaces: SPR8-220.031.02.01.02
© S iem ens AG 2002
The reproduction, transmission or
use of this document or its contents
is not permitted without express
written authority. Offenders will be
liable for damages. All rights,
including rights created by patent
grant or registration of a utility
model
_or_ design,_are_
reserved.
English
Doc. Gen. Date: 11.02
66 47 007

Advertisement

Table of Contents
loading

Summary of Contents for Siemens Mobilett Plus

  • Page 1 Mobilett Plus/ E/ M/ HP Service Installation Instructions Installation of remote exposure switch system © S iem ens AG 2002 The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages.
  • Page 2 Assemblers and other persons who are not employed by or otherwise directly affiliated with or autho- rized by Siemens or one of its affiliates are directed to contact one of the local offices of Siemens or one of its affiliates before attempting installation or service procedures.
  • Page 3: Table Of Contents

    Remote control, TechSwitch (Option) ......4 - 5 Siemens-Elema AB SPR8-220.031.02 Page 3 of 4 Mobilett Plus/ E/ M/ HP Solna, Sweden Rev. 02 11.02...
  • Page 4 0 - 4 Contents This page intentionally left blank. Mobilett Plus/ E/ M/ HP SPR8-220.031.02 Page 4 of 4 Siemens-Elema AB Service Rev. 02 11.02 SPS-UD Solna, Sweden...
  • Page 5: Purpose

    1 - 1 Purpose This document describes how to install a remote exposure switch system on a Mobilett Plus/ Plus E/ Plus M/ Plus HP. Important note After the installation is done, separate the last chapter, "the Supplement to the Instruc- tions for Use", from the document.
  • Page 6: Safety Information

    Checks and adjustments performed with radiation ON are identified by the radiation warning symbol During these types of adjustments, radiation protective clothing must be worn. Observe all MOBILETT safety guidelines. Mobilett Plus/ E/ M/ HP SPR8-220.031.02 Page 2 of 2 Siemens-Elema AB Service Rev.
  • Page 7: Assembly

    Measure the discharge procedure between measuring points CAPPOS and CAPNEG on the D7 board (pos 6 / Fig. 1) with a digital multimeter. NOTICE For MOBILETT Plus HP only: Remove the cover in front of the batteries. Disconnect one of the blue battery connector pairs.
  • Page 8 Smoothen the sharp edges of the newly drilled holes with a file. SIDE VIEW TOP VIEW ± ± ± ± ± Fig. 2 Positioning of holes Mobilett Plus/ E/ M/ HP SPR8-220.031.02 Page 2 of 8 Siemens-Elema AB Service Rev. 02 11.02 SPS-UD Solna, Sweden...
  • Page 9 (pos 1 / Fig. 5). Module connector Remote sensor Fig. 5 Siemens-Elema AB SPR8-220.031.02 Page 3 of 8 Mobilett Plus/ E/ M/ HP Solna, Sweden Rev. 02 11.02 SPS-UD Service...
  • Page 10 Fasten the ground connector cable (pos 10 / Fig. 6). Make sure the washers are oriented as described in Fig. 6. Position the provided tie-mounts to the areas indicated in Fig. 6 at pos 5, 6 and 7. Mobilett Plus/ E/ M/ HP SPR8-220.031.02 Page 4 of 8...
  • Page 11: Functional Check

    When setting the exposure parameters use the lowest possible values for kV and mAs. NOTICE For MOBILETT Plus HP only: Reconnect the loose battery connector pair. ’ON’ LED (Green, LED4) Description: Illuminates when the X-ray unit is turned on.
  • Page 12 Make a series of exposures to be certain the remote system is functioning properly. Set the kV to 90 and 125 (133 if possible) and maximum mAs for the exposures. Mobilett Plus/ E/ M/ HP SPR8-220.031.02 Page 6 of 8...
  • Page 13: Final Procedures

    (with the remote finder feature and low battery indicator) in the holder, and store the second spare (included in the delivery) in a safe place in the Radiology Department. Mobilett Plus HP Mobilett Plus/ Plus E/ Plus M Fig. 7 Placing of remote holder on Mobilett Siemens-Elema AB SPR8-220.031.02...
  • Page 14 2 - 8 Installation This page intentionally left blank. Mobilett Plus/ E/ M/ HP SPR8-220.031.02 Page 8 of 8 Siemens-Elema AB Service Rev. 02 11.02 SPS-UD Solna, Sweden...
  • Page 15 3 - 1 New components added for installation; ferrite core and ground connector cable. Image on page 2-4 updated. Safety notes revised. Siemens-Elema AB SPR8-220.031.02 Page 1 of 2 Mobilett Plus/ E/ M/ HP Solna, Sweden Rev. 02 11.02 SPS-UD Service...
  • Page 16 3 - 2 Changes to previous version This page intentionally left blank. Mobilett Plus/ E/ M/ HP SPR8-220.031.02 Page 2 of 2 Siemens-Elema AB Service Rev. 02 11.02 SPS-UD Solna, Sweden...
  • Page 17: Design And Function

    Vertical column Remote control (Option) Remote control (Option) Remote holder (Option) Remote holder (Option) Transport safeguard Transport safeguard Mobilett Plus/ Plus E/ Plus M Mobilett Plus HP Siemens-Elema AB SPR8-220.031.02 Page 1 of 6 Mobilett Plus/ E/ M/ HP Solna, Sweden Rev.
  • Page 18: Remote Control (Option)

    (option) in line-of sight. This includes any units behind a window or lead glass. If there are other mobiles in line-of-sight, power down those mobiles while operating the other. Mobilett Plus/ E/ M/ HP SPR8-220.031.02 Page 2 of 6...
  • Page 19: Operation

    The beeps will continue indefinitely until the remote control is located and put back in the remote holder. Siemens-Elema AB SPR8-220.031.02 Page 3 of 6 Mobilett Plus/ E/ M/ HP Solna, Sweden Rev. 02 11.02 SPS-UD Service...
  • Page 20: Remote Control (Option) Features

    Press again and hold to make the exposure Battery compartment (9-volt alkaline included) * These features are not implemented in the spare remote control (included in the kit) Mobilett Plus/ E/ M/ HP SPR8-220.031.02 Page 4 of 6 Siemens-Elema AB Service Rev.
  • Page 21: Technical Specifications

    180i; Remote Sensor built into the front arm of X-ray unit Remote control kit includes: Two remote controls (one spare), IR sensor with modular cable, PCB electronics package with flat cable Siemens-Elema AB SPR8-220.031.02 Page 5 of 6 Mobilett Plus/ E/ M/ HP Solna, Sweden Rev. 02 11.02 SPS-UD Service...
  • Page 22 4 - 6 Supplement to the Instructions for Use This page intentionally left blank. Mobilett Plus/ E/ M/ HP SPR8-220.031.02 Page 6 of 6 Siemens-Elema AB Service Rev. 02 11.02 SPS-UD Solna, Sweden...

This manual is also suitable for:

Mobilett plus eMobilett plus mMobilett plus hp

Table of Contents