3.6
Power supply
This interface is provided for connection of the external power supply.
Note
When using external power supplies (e.g. SITOP), the ground potential must be connected
with the protective ground terminal (PELV).
Characteristics of the interface
Table 3- 14
Characteristics
Connector type
Connection possibility
Max. current carrying capacity incl. loop-through
Max. cable length
Interface assignments
Table 3- 15
Pin
1
2
3
4
Note
The 24 V is looped through via the 24 V connector. In this case, pin 1 is jumpered with pin 2,
and pin 3 is jumpered with pin 4 in the connector. The maximum current can be limited
through the current carrying capacity of the cable. The current carrying capacity of the cable
depends, for example, on the type of cable installation (cable duct, laying on a cable
rack, etc.)
SIMOTION D4x5-2
Manual, 11/2010
Interface X124
Power supply X124
Signal name
P24
P24
M
M
Type
Combicon
Up to 2.5 mm
2
20 A
10 m
Meaning
24 V power supply
24 V power supply
Ground
Ground
Interfaces
3.6 Power supply
55