• Maintenance • Service and Adjustments • Troubleshooting • Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.sears.com/craftsman N014212 Rev. 0 7/24/08...
Model No. Running HP Bore Stroke Voltage-Single Phase Minimum Branch Circuit Requirement Fuse Type Air Tank Capacity Approx. Cut-In Approx. Cut-out SCFM @ 40 PSIG SCFM @ 90 PSIG *Tested per ISO 1217 Refer to Glossary for abbreviations. SAFETY GUIDELINES - DEFINITIONS This manual contains information that is important for you to know and under- stand.
WHAT CAN HAPPeN • It is normal for electrical contacts within the motor and pressure switch to spark. • If electrical sparks from compressor come into contact with flammable vapors, they may ignite, causing fire or explosion. • Restricting any of the compressor ventilation openings will cause seri- ous overheating and could cause fire.
Page 5
RISK OF BURSTING Air Tank: The air tank on your Air Compressor is designed and may be UM coded (for units with air tanks greater than 6" (122 mm) diameter) according to ASME Section VIII, Div. 1 rules. All pressure vessels should be inspected once every two years.
Over inflation of tires could result in serious injury and property damage. WHAT CAN HAPPeN • Your air compressor is powered by electricity. Like any other electrically powered device, If it is not used properly it may cause electric shock.
Page 7
RISK FROM FLYING OBJECTS WHAT CAN HAPPeN • The compressed air stream can cause soft tissue damage to exposed skin and can propel dirt, chips, loose particles, and small objects at high speed, resulting in property damage or personal injury. WHAT CAN HAPPeN •...
Page 8
• Review and understand all instruc- tions and warnings in this manual. • Become familiar with the operation and con trols of the air compressor. • Keep operating area clear of all per- sons, pets, and obstacles. • Keep children away from the air compressor at all times.
Air Hose: 1/4", 3/8" or 1/2" I.D. in various lengths This air compressor pump is capable of running continuously. However, to prolong the life of your air compressor, it is recommended that a 50%-75% GLOSSARY continue to use your accessory. When...
Unpacking Remove unit from carton and discard all packaging. HOW TO SET UP YOUR UNIT Location of the Air Compressor • Locate the air compressor in a clean, dry and well ventilated area. • The air compressor should be located at least 12" (30.5 cm)
extension Cords If an extension cord must be used, be sure it is: • a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the product • in good condition •...
"cut-out" pressure. Safety Valve: If the pressure switch does not shut off the air compressor at its "cut-out" pressure setting, the safety valve will protect against high pressure by "popping out" at its factory set pressure (slightly higher than the pressure switch "cut-out"...
This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced. Make sure the On/Off switch is in the "Off"...
How to Start: Set the On/Off switch to "On" and allow tank pressure to build. Motor will stop when tank pressure reaches "cut-out" pressure. Turn regulator knob clockwise to increase pressure and stop when desired pressure is reached. Customer Responsibilities Check Safety Valve Drain Tank Unit cycles...
When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.
Manifold Hose Clamp Remove pump mounting screws securing pump (one on each side). Pump Mounting Screw Before you store the air compressor, make sure you do the following: Review the Maintenance section on the preceding pages and perform scheduled maintenance as necessary.
When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.
Page 18
Decrease amount of air usage. Check the accessory air requirement. If it is higher than the SCFM or pressure supplied by your air compressor, you need a larger compressor. Check and replace if required. Remove and clean, or replace.
Page 19
PrOBLeM Regulator will not shut off air outlet. Motor will not run. CAUSE Damaged regulator. Fuse blown, circuit breaker tripped. Extension cord is wrong length or gauge. Loose electrical connections. Faulty motor. Motor overload protec- tion switch has tripped 19 - ENG COrreCTiON Replace.
Page 25
® 1-800-4-MY-HOME Contratos de Protección Maestra Felicitaciones por hacer una compra inteligente. Su nueva unidad Craftsman ® está diseñada y fabricada para años de operación confiable; pero como todos los productos de calidad, podría requirir reparaciones de vez en cuando. Ahí es cuando el Contrato de Protección Maestra le puede ahorrar dinero y...
Page 26
Get it fixed, at your home or ours! For repair – in your home – of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories and owner’s manuals that you need to do-it-yourself.