  • Page 1 Fundamental safety instructions Overview Dimension drawings SINUMERIK Operator control and display elements SINUMERIK ONE ONE MCP Part 2: MCP 1900.2 Technical data Equipment Manual Valid for: Control system SINUMERIK ONE SINUMERIK 840D sl/840DE sl 01/2023 A5E52559449B AA...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Fundamental safety instructions......................5 General safety instructions....................5 Equipment damage due to electric fields or electrostatic discharge ........9 Warranty and liability for application examples ..............9 Security information ......................9 Residual risks of power drive systems ................. 11 Overview..............................
  • Page 4 Table of contents ONE MCP Part 2: MCP 1900.2 Equipment Manual, 01/2023, A5E52559449B AA...
  • Page 5: Fundamental Safety Instructions

    Fundamental safety instructions General safety instructions WARNING Electric shock and danger to life due to other energy sources Touching live components can result in death or severe injury. • Only work on electrical devices when you are qualified for this job. •...
  • Page 6 Fundamental safety instructions 1.1 General safety instructions WARNING Electric shock due to equipment damage Improper handling may cause damage to equipment. For damaged devices, hazardous voltages can be present at the enclosure or at exposed components; if touched, this can result in death or severe injury.
  • Page 7 • Therefore, if you move closer than 20 cm to the components, be sure to switch off radio devices, cellphones or WLAN devices. • Use the "SIEMENS Industry Online Support app" only on equipment that has already been switched off. WARNING...
  • Page 8 Fundamental safety instructions 1.1 General safety instructions NOTICE Overheating due to inadmissible mounting position The device may overheat and therefore be damaged if mounted in an inadmissible position. • Only operate the device in admissible mounting positions. WARNING Unexpected movement of machines caused by inactive safety functions Inactive or non-adapted safety functions can trigger unexpected machine movements that may result in serious injury or death.
  • Page 9: Equipment Damage Due To Electric Fields Or Electrostatic Discharge

    In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks.
  • Page 10 Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure...
  • Page 11: Residual Risks Of Power Drive Systems

    Fundamental safety instructions 1.5 Residual risks of power drive systems Residual risks of power drive systems When assessing the machine or system-related risk in accordance with the respective local regulations (e.g. EC Machinery Directive), the machine manufacturer or system integrator must take into account the following residual risks emanating from the control and drive components of a drive system: 1.
  • Page 12 Fundamental safety instructions 1.5 Residual risks of power drive systems 6. Influence of network-connected communication systems, e.g. ripple-control transmitters or data communication via the network 7. Motors for use in potentially explosive areas: When moving components such as bearings become worn, this can cause enclosure components to exhibit unexpectedly high temperatures during operation, creating a hazard in areas with a potentially explosive atmosphere.
  • Page 13: Overview

    Overview This manual describes the specific properties of the SINUMERIK ONE MCP 1900.2 machine control panel. The documentation is always structured in 2 parts. Part 1 contains general information that applies to all machine control panels. Part 2 covers specifics of individual machine control panels.
  • Page 14 Overview ONE MCP Part 2: MCP 1900.2 Equipment Manual, 01/2023, A5E52559449B AA...
  • Page 15: Dimension Drawings

    Dimension drawings Plus wiring portion Figure 3-1 Front, rear, and side view of MCP 1900.2 (all specifications in mm) The installation clearance for the MCPs is 70 mm including the wiring portion. ONE MCP Part 2: MCP 1900.2 Equipment Manual, 01/2023, A5E52559449B AA...
  • Page 16 Dimension drawings Panel cutout The MCP 1900.2 is secured using 12 M5 nuts. The tightening torque is 1.5 Nm. In addition to the M5 nuts, use the spring elements provided. Customers are responsible for the geometry of the panel cutout, as well as mounting the MCP in the housing. To mechanically protect the outer edge of the front panel, the device must be installed so that it is recessed by at least 0.5 mm with respect to the surrounding housing.
  • Page 17: Operator Control And Display Elements

    Operator control and display elements Front side Overview ① Emergency stop ② Keypad 1 (operating mode block) ③ Keypad 2 (axis block) ④ Powerride 1 (spindle) + keypad 2.2 ⑤ Powerride 2 (feed) + keypad 2.1 ⑥ Key-operated authorization switch ②...
  • Page 18: Rear Side

    Operator control and display elements 4.3 Configuration Rear side ① PE/ground connection ∎ Power supply interface X10 ③ Switch S2 ④ Ethernet interfaces X20 port 1/ port 2 ⑤ Handwheel connections X60/ X61 ⑥ EMERGENCY STOP ⑦ 4x mounting space for 22.5 mm element ②...
  • Page 19 Operator control and display elements 4.3 Configuration Slot 6 Handwheel 1 Slot 7 Handwheel 2 Output image Slot 1 Base Slot 2 Keypad 1 (operating mode block) Slot 3 Keypad 2 (axis block) Slot 4 Powerride 1 (feed) Slot 5 Powerride 2 (spindle) ONE MCP Part 2: MCP 1900.2 Equipment Manual, 01/2023, A5E52559449B AA...
  • Page 20 Operator control and display elements 4.3 Configuration ONE MCP Part 2: MCP 1900.2 Equipment Manual, 01/2023, A5E52559449B AA...
  • Page 21: Technical Data

    Technical data   MCP 1900.2 Safety Safety class according to EN 50178 III; PELV Degree of protection according to EN Front: IP54 Rear: IP00 60529 Approvals CE / EAC / UL / UKCA Flame resistance UL 94 V-1 UL identifier MCPS2206-464165E-342051AA0 Electrical data Overvoltage category Secondary circuit supplied from primary circuits up to Cat.
  • Page 22 Technical data   MCP 1900.2 Relative humidity 5 ... 90% (without condensation) Permissible change in the relative humid‐ Max. 6%/h Pollution degree 2 (only use indoors) Mechanical environmental conditions Classification of the mechanical environ‐ Class 3M2 according to EN 60721-3-3 ment Vibration load during operation Frequency range: 10 –...
  • Page 23 Technical data Emergency stop button Rated voltage 24 V DC Current rating, max. Current rating, min. 1 mA Switching capacity DC 13 according to EN 60947-5-1 Conditional rated short-circuit current 10 A gL/gG according to EN 60947-5-1 500000 Note The quantitative assessment of the emergency stop safety function must be based on the B values corresponding to the used standards (e.g.
  • Page 24 Technical data ONE MCP Part 2: MCP 1900.2 Equipment Manual, 01/2023, A5E52559449B AA...
  • Page 25: Index

    Index MCP 1900.2 Emergency stop button, 23 Technical data, 21 Current consumption, 21 Power consumption, 21 ONE MCP Part 2: MCP 1900.2 Equipment Manual, 01/2023, A5E52559449B AA...
  • Page 26 Index ONE MCP Part 2: MCP 1900.2 Equipment Manual, 01/2023, A5E52559449B AA...