MANUAL SIMBOLOGY USER AUTHORISED TECHNICIAN (ONLY to interpret or the Stove-manufacturer or the Authorized Techni- cian of Technical Assistance Service approved by the Stove-manufacturer) SPECIALIZED STOVE-REPAIRER CAUTION: READ CAREFULLY THE NOTE CAUTION: DANGER OR IRREVERSIBLE DAMAGE POSSIBILITY • The icons with the stylized figures indicates whom the subject dealt in the paragraph is addressed to (between the User and/ or the Authorized Technician and/or the Specialized Stove-repairer).
• Remove the brackets which secure the feet of the stove (see Fig. 1). Then remove the stove from the pallet. STOVE HANDLING Both whether the stove is packed or not it is necessary to observe the following instructions for handling and transporting the stove from its sale point to its installation point and for any future movements: •...
TECHNICAL FEATURES Fig. 3 - Inclined roof LEGEND Fig. 3 Height over the ridge of the roof = 0,5 mt Roof inclination ≥ 10° 90° Measured distance at 90° from the roof surface = 1,3 mt • The chimney flue must be sealed from fumes. •...
Fig. 4 - Example of label HEIGHT-DEPRESSION The depression (draught) of a chimney flue depends also on its height. Check the depression with the values provided at FEATU- RES a pag. 24. Minimum height 3,5 meters. MAINTENANCE • The fumes extraction pipes (fumes conduit + chimney flue + chimney pot) must always be cleaned, scrubbed and checked by an expert stove-repairer, in compliance with current regulations, with the instructions of the stove-manufacturer and the directives of your insurance company.
CHIMNEY COMPONENTS Fig. 6 - Chimney components LEGEND Fig. 6 Chimney pot Fume outlet Chimney flue Termal insulation External wall Chimney union Fume pipe Heat generator Inspection door T-union with inspection plug CHIMNEY FLUE CONNECTION Your pellet stove works through a fume draught forced by a fan. It is obligatory to check that all pipes are realized in compliance with the following regulation on material selection: EN 1856-1, EN 1856-2 e UNI/TS 11278.
SYSTEM TYPE Ø80 mm PIPE Ø100 mm PIPE Minimum vertical length 1,5 mt 2 mt Maximum length (with 1 union) 6,5 mt 10 mt Maximum length (with 3 unions) 4,5 mt 8 mt Maximum number of unions Level section (minimum inclination 3%) 2 mt 2 mt Installation at a height above 1200 m a.s.l.
Page 9
Fig. 8 - Example 2 LEGEND Fig. 8 Insulating material Inspection plug Chimney inspection entrance Minimum safety distance = 0,5 mt Inclination ≥ 3° Level section ≤ 1 mt • Old chimney flue with an inserted pipe of minimum Ø100/120 mm and with an external door which enables the chimney cleaning.
• External chimney flue entirely made up of insulated stainless steel pipes, i.e. with double wall of minimum Ø100/120 mm: all must be firmly attached to the wall. For chimney against wind effects please (see Fig. 5). • Ducting system through T-unions which enables an easy cleaning without disassembling the pipes. We recommend to check with your chimney flue manufacturer the safety distances which must be respected and the type of insulating material.
COMBUSTIBLE AIR INLET FOR SEALED-CHAMBER INSTALLATION Fig. 11 - Air inlet for sealed-chamber installation LEGEND Fig. 11 ≥ 1,5 mt ≥ 0,3 mt Sectional view Shield grid Curve inlet to turn downwards Check if the purchased stove has a sealed-chamber. If the stove is endowed with a sealed-chamber and you want also the whole installation with sealed chamber, please read the following instructions: •...
COMBUSTIBLE AIR INLET FOR SEALED-CHAMBER INSTALLATION How to connect to the stove in the sealed chamber with concentric system: Fig. 12 - Phase1 • Connect the air intake pipe to the combustion air pipe of the stove and tighten everything with a clamp (see [Fig. 12). INSTALLATION INTRODUCTION •...
OVERALL DIMENSIONS Fig. 13 - General dimensions: VERA 7 - VERA 7.0 LEGEND Fig. 13 90,7 cm 45,2 cm 45,7 cm 18,2 cm 31,4 cm 12,9 cm 20,2 cm Exhaust fumes d.8 cm Hole combustion air inlet d.6 cm Fig. 14 - General dimensions:INDIGO EVO - INDIGO EVO 7...
Page 14
31,4 cm 12,9 cm 20,2 cm Exhaust fumes d.8 cm Hole combustion air inlet d.6 cm Fig. 15 - General dimensions: VERA 7.0 UP LEGEND Fig. 15 Exhaust fumes d.8 cm Hole combustion air inlet d.6 cm Fig. 16 - General dimensions: CRISTAL7.0 UP LEGENDA Fig.
GENERAL INSTALLATION Fig. 17 - General installation LEGEND Fig. 17 Stove Minimum lateral distance = 300 mm Minimum rear distance = 200 mm Minimum front distance = 1000 mm • It is obligatory to install the stove away from walls and/or pieces of furniture, with a minimum air flow of 300 mm on the sides and 200 mm on the back, to enable an eficient appliance cooling and a good distribution of heat in the room (see Fig.
REMOVAL/ASSEMBLY OF SIDE PANELS To disassemble the side panels, proceed as follows: • Undo the front screws (see Fig. 21). • Open the side panel (see Fig. 22) and release the rear teeth (see Fig. 23). • To assemble, proceed in reverse order. Fig.
• Press the menu key for a few seconds (1). • Repeatedly press the P2 key until M8 - Technical settings "M8-SEt tEcHnic " appears. • Select by pressing the P3 key. • Set the password with keys P1 or P2 (keeping the key pressed accelerates the setting). •...
SPECIAL MAINTENANCE INTRODUCTION For a long working life of the stove, have a periodic cleaning of the stove as described in the following paragrafs. • Fume outlet pipes (fume conduit + chimney flue + chimney pot) must always be cleaned, scrubbed and checked by an autho- rized technician in compliance with local regulations, with the instructions of the manufacturer and those of your insurance company.
Page 19
Fig. 29 - Remove the screws Fig. 30 - Remove the inspection cap • Open the door. • Remove the 4 screws (see Fig. 32) and remove the inspection cap (see Fig. 32). Fig. 31 - Clean with pipe cleaner Fig.
ROOM FAN CLEANING Clean every the year the room fan from ash or dust which can cause a blade unbalance and a greater noise. Fig. 35 - Room fan cleaning • Remove the sides. • Remove dust build-up using a brush or a vacuum cleaner (see Fig. 35). FUME PIPES ANNUAL CLEANING Clean annually from soot with brushes.
Page 21
PROBLEM CAUSE SOLUTION INTERVENTION The stove is without power Check if the plug is connected. supply Burned protection Replace the protection fuses in the electric socket (3.15A- fuse in the electric 250V). socket The control display Faulty control Replace the control display. does not switch on display Faulty flat cable...
Page 22
PROBLEM CAUSE SOLUTION INTERVENTION Check as following: probable obstructions of the combusti- Not sufficient ble air inlet from the back or from the bottom of the stove; combustion air burning pot obstructed holes with too ash remains. Have the fan blades and auger cleaned. The exhaust chimney is partially or totally obsturcted.
TECHNICAL DATAS REPAIR INFORMATION Now we give some instructions for the Authorized Technician to take into consideration to have access to stove mechanical components. • For fuse replacement in the electric socket which stands on the back of the stove, extract the fuses to change with the aid of a screwdriver for opening the shutter (see Fig.
FEATURES DESCRIPTION VERA 7 INDIGO EVO WIDTH 45 cm 45 cm DEPTH 45,5 cm 45,5 cm HEIGHT 89,5 cm 89,5 cm WEIGHT 59 kg 59 kg INTRODUCED THERMIC POWER (Min/Max) 2,8 - 7,7 kW 2,8 - 7,7 kW NOMINAL THERMIC POWER (Min/Max) 2,6 - 7 kW 2,6 - 7 kW EFICIENCY (Min/Max)
Page 25
DESCRIPTION VERA 7.0 INDIGO EVO7 WIDTH 45 cm 45 cm DEPTH 45,5 cm 45,5 cm HEIGHT 89,5 cm 89,5 cm WEIGHT 59 kg 59 kg INTRODUCED THERMIC POWER (Min/Max) 2,8 - 7,7 kW 2,8 - 7,7 kW NOMINAL THERMIC POWER (Min/Max)
Page 26
DESCRIPTION VERA 7.0 UP CRISTAL3 7.0 UP WIDTH 45,2 cm 45,2 cm DEPTH 45,7 cm 45,7 cm HEIGHT 91,2 cm 91,2 cm WEIGHT 59 kg 59 kg INTRODUCED THERMIC POWER (Min/Max) 2,8 - 7,7 kW 2,8 - 7,7 kW NOMINAL THERMIC POWER (Min/Max)