hit counter script
Table of Contents

Advertisement

Quick Links

SIMATIC IPC BX-35A
SIMATIC
Industrial PC
SIMATIC IPC BX-35A
Operating Instructions
04/2024
A5E52539873-AA
Preface
Overview
Safety instructions
Installing and connecting
the device
Installing OS and SDK
components
Security
Expanding the device
Maintaining and repairing
the device
Technical specifications
Technical support
Digital I/O and CAN
terminal block
Markings and symbols
List of abbreviations
1
2
3
4
5
6
7
8
A
B
C
D

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC IPC BX-35A

  • Page 1 SIMATIC IPC BX-35A Preface Overview SIMATIC Safety instructions Installing and connecting the device Industrial PC SIMATIC IPC BX-35A Installing OS and SDK components Security Operating Instructions Expanding the device Maintaining and repairing the device Technical specifications Technical support Digital I/O and CAN...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3 • SIMATIC IPC BX-35A Quick Install Guide • SIMATIC IPC BX-35A Operating Instructions (this file) Conventions The term "device" is sometimes used to refer to the SIMATIC IPC BX-35A in this documentation. Figures This manual contains figures of the described devices. The supplied device may differ in some details from the figures.
  • Page 4: Table Of Contents

    Downloading Support Package Manager ................34 4.1.3 Installing Support Package Manager ................... 34 4.1.4 Installing JetPack Operating System ................... 35 Installing the Jetson™ SDK components ................35 Adjusting power and performance ..................35 Security ..............................39 SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 5 Motherboard ........................80 8.8.2 External Interfaces ......................81 8.8.2.1 Overview of external interfaces ..................81 8.8.2.2 Power supply ........................81 8.8.2.3 Digital I/O connector ......................82 8.8.2.4 USB ........................... 84 8.8.2.5 DisplayPort ........................85 SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 6 Digital I/O and CAN terminal block ...................... 95 Markings and symbols ......................... 97 Overview ........................... 97 Safety ..........................97 Operator controls....................... 97 Certificates, approvals and markings .................. 98 Interfaces .......................... 99 List of abbreviations .......................... 101 Index ..............................103 SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 7: Overview

    Product description Features SIMATIC IPC BX-35A is powered by the NVIDIA® Jetson™ Orin NX module. It's a new generation of embedded edge computing products for high AI performance. It provides high- level industrial functionality, flexible expansion ability and a compact form factor for installation.
  • Page 8: Structure Of The Device

    1.2 Structure of the device Structure of the device 1.2.1 Views of the device Front view ① Cooling fins ② Power LED indicator ③ User defined function indicator ④ DI/DQ LED indicator Side view SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 9: Interfaces Of The Device

    USB 3.0 port 3 × USB 3.0 Type A, high current (X60/X62/X63) ⑥ DPP (X70) 1 × DisplayPort connection ⑦ USB 2.0 port (X61) 1 × USB 2.0 Micro B port, device mode only SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 10: Status Displays

    Description DI0 / DI1/DI2 /DI3 Digital input no data transmission or data transmission low. Green Digital input data transmission high. DQ0 /DQ1/DQ2/DQ3 Digital output data transmission low. Green Digital output data transmission high. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 11: Accessories

    System sleep USER Off/Red/Green/Orange Customizable Accessories Accessories from Siemens are available for your device. These are not included in the scope of delivery. Additional accessories can be found on the Internet: • Industry mall (https://mall.industry.siemens.com) • Expansion components and accessories (https://new.siemens.com/global/en/products/automation/pc-based.html)
  • Page 12 Overview 1.3 Accessories SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 13: Safety Instructions

    Risk of fire through expansion cards Expansion cards generate additional heat. The device may overheat and cause a fire. Note the following: • Observe the safety and installation instructions for the expansion cards. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 14 LEDs on a plug-in card in the device visible. • Cables are routed from the inside out of the device or from the outside into the device, for example, to connect sensors or displays. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 15 When you touch electrostatic sensitive components, you can destroy them through voltages that are far below the human perception threshold. If you work with components that can be destroyed by electrostatic discharge, observe the ESD Guideline (Page 71). SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 16: Cybersecurity Information

    Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
  • Page 17: Notes On Use

    Security notification Siemens recommends that you observe the following security practices: • Enable Secure boot feature to the first stage of boot/kernel/DTB to prevent attack. • Use SHA512 algorithm for public key hash collision.
  • Page 18 • Use separate accounts for admin tasks and user tasks. • Only install software components from trusted sources. • Change the system password regularly. • The device can be identified by collecting MAC/UID information from the system. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 19: Installing And Connecting The Device

    Death or serious injury could occur. • Make sure that the damaged device is not installed or put into operation. • Label the damaged device and keep it locked away. • Send off the device for immediate repair. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 20: Identification Data Of The Device

    Production version All existing Ethernet addresses (MAC) The following image shows the product label on the SIMATIC IPC BX-35A as an example. ID link The ID link is a globally unique identifier according to IEC 61406, which you can find as a QR code on the product and product packaging.
  • Page 21: Permitted Mounting Positions And Mounting Types

    Ensure that the following clearances measurements to another component or to a wall of a housing are complied with: • Below the device: ≥ 100 mm • Above the device: ≥ 50 mm SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 22: Mounting The Device

    (such as the provision of clean air), SIMATIC Box PCs may not be operated in harsh environments that are subject to caustic vapors or gases. Possible mounting types of the device: Mounting on DIN rails Wall mounting SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 23 This can result in personal injuries or material damage. Ensure that the wall is capable of bearing four times the total weight of the device (including the brackets and expansion modules). The total weight of the device is approximately 1.76 kg. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 24: Mounting On Din Rails

    Mounting on DIN rails Mounting on a standard rail is suitable for horizontal mounting of the device. Requirements • A SIEMENS 35 mm standard rail TH35-15 conforming to EN 60715:2001 The standard rail is mounted. • A standard rail bracket The standard rail bracket and two screws are included.
  • Page 25: Wall Mounting

    2 screws. Place the device with the mounting brackets onto the mounting surface. Mark the fixing holes. Drill the fixing holes. Insert the anchors in the drilled holes. Screw on the device. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 26: Connecting The Device

    • Only connect I/O devices which are approved for industrial applications in accordance with EN 61000-6-2 and IEC 61000-6-2. • I/O devices that are not hot-pluggable may only be connected after the device has been disconnected from the power supply. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 27: Connecting The Protective Conductor

    • Never operate the device without a protective conductor. • If a device is defective, remove it from operation without delay and label it accordingly. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 28: Connecting The Power Supply

    • If the device is installed in an enclosure that complies with section 9.3.2. c) of IEC/UL/EN/DIN-EN 61010-1 and IEC/UL/EN/DIN-EN 61010-2-201, the unit can be powered from a source "greater than NEC Class 2 / Limited Energy". The device is then classified as "OPEN EQUIPMENT". SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 29 Connect the two-core cable to the cable head separately. Connect the cable heads to the power supply terminal block. Tighten the screws on the terminal block at shown. Plug the terminal block into the power supply interface X80. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 30: Installing Os And Sdk Components

    SSD. And the Siemens Support Package will be installed automatically. • Siemens recommends you use SPM to install Jetson™ Linux® on IPC BX-35A. If you use other tools for the installation, certain functions of IPC BX-35A might not work properly.
  • Page 31: Downloading Support Package Manager

    For example: sudo ./SPM BX-35A jp5.1.2 NVME 4.1.2 Downloading Support Package Manager Support Package Manager (SPM) is published on Siemens Industry Online Support website. To download SPM, log in to Siemens Industry Online Support website (https://support.industry.siemens.com/cs/ww/en/view/109783704). Find and click on the SIMATIC IPC520A / IPC BX-35A entry.
  • Page 32: Installing Jetpack Operating System

    The default power mode configuration for BX-35A is 15W mode. NVIDIA® offers the powerestimator tool to adjust the power and performance according to your specific needs. For detailed information, please refer to the official NVIDIA® documentation (https://docs.nvidia.com/jetson/archives/r35.4.1/DeveloperGuide/text/SD/PlatformPowerAndP erformance/JetsonOrinNanoSeriesJetsonOrinNxSeriesAndJetsonAgxOrinSeries.html). SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 33 ID value 0 with the value 4: < POWER_MODEL ID=0 NAME=MODE_22_9_W > CPU_ONLINE CORE_0 1 CPU_ONLINE CORE_1 1 CPU_ONLINE CORE_2 1 CPU_ONLINE CORE_3 1 CPU_ONLINE CORE_4 1 CPU_ONLINE CORE_5 1 CPU_ONLINE CORE_6 0 CPU_ONLINE CORE_7 0 SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 34 CPU_A78_1 MAX_FREQ 1497600 GPU MIN_FREQ 0 GPU MAX_FREQ 918000000 GPU_POWER_CONTROL_DISABLE GPU_PWR_CNTL_DIS auto EMC MAX_FREQ 0 DLA0_CORE MAX_FREQ 614400000 DLA1_CORE MAX_FREQ 614400000 DLA0_FALCON MAX_FREQ 294400000 DLA1_FALCON MAX_FREQ 294400000 PVA0_VPS MAX_FREQ 512000000 PVA0_AXI MAX_FREQ 358400000 SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 35 11.Restart the device. You can switch to the custom power and performance configuration in the Power mode menu. Note The name of the custom configuration can be modified in step 10 command line < POWER_MODEL ID=4 NAME=MODE_22_9_W >. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 36: Security

    OPTEE, the user key PTA extracts this key, and when the system boots to UEFI, the OS Loader (L4tLauncher) calls the TA to decrypt and loads the encrypted UEFI payloads. For detailed information: UEFI Payload Encryption (https://docs.nvidia.com/jetson/archives/r35.4.1/DeveloperGuide/text/SD/Security/SecureB oot.html#sd-security-secureboot-uefipayloadencryption). SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 37: Disk Encryption

    • The fuses mentioned in this chapter can only be burned once. If the fuse keys are lost or compromised, the device is no longer safe. • If the device was burned with the wrong fuse value, it may become bricked. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 38 • <JetPack Version> specifies the JetPack version, you can get the supported JetPack version by command sudo ./SPM -l. • <rootdev> specifies the root device to store the rootfs in device. You can get the supported root device by command sudo ./SPM -l. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 39: Preparing Keys

    Public Key Cryptography (PKC) Generate an asymmetric key pair for PKC key. Refer to Generate A PKC Key Pair (https://docs.nvidia.com/jetson/archives/r35.4.1/DeveloperGuide/text/SD/Security/SecureBoot. html#generate-a-pkc-key-pair). IPC BX-35A (Based on Jetson™ Orin NX) only support RSA-3K/ECDSA P-256/ECDSA P-521. For example: SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 40 For example, you can input the below command to generate the OEM key: #Generate key for OemK1, the key value will be saved to OemK1.key $ openssl rand -rand /dev/random -hex 32 > OemK1.key SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 41: Creating Pkc Hash By Spm

    You must follow the above steps again to generate hash value for PKC1 and PKC2 key respectively. 5.2.3 Creating the fuse configuration file Requirements • Hash values for PKC0/PKC1/PKC2 are generated, see Creating PKC hash by SPM (Page 44). SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 42 – The Fuse Configuration File contains SBK value, so the value for Bit[3] should be 1b. – The ODM Key is valid, so the value for Bit[9] should be 1b. The BootSecurityInfo should be filled with 00000000000000000000001000001010b, which is 0x20A with hex format. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 43: Verifying The Fuse Configuration File

    5. Input y (or Y) and press the Enter key to start to test the Fuse Configuration File. 6. If no error was detected in the Fuse Configuration File, the message Success to test burning fuse will be displayed. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 44: Burning Fuse By Spm

    5. Press the Enter key to skip the test function and burn fuse directly. 6. Input Yes and press the Enter key to burn fuse. 7. If no error message is displayed after burning fuse process completed, the fuses are successfully burned. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 45: Installing Secured Images

    -sha256 -days 3650 -subj "/CN=my Platform Key/" -out PK.crt #4. Generate KEK RSA keypair and certificate $ openssl req -newkey rsa:2048 -nodes -keyout KEK.key -new - x509 -sha256 -days 3650 -subj "/CN=my Key Exchange Key/" -out SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 46 Enter key. Note After the installing process is finished successful, you can check if the UEFI Secureboot is enabled after the device startup. See Check if UEFI Secureboot is enabled (https://docs.nvidia.com/jetson/archives/r35.4.1/DeveloperGuide/text/SD/Security/SecureB oot.html#check-if-uefi-secureboot-is-enabled). SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 47: Installing The Os Image With Uefi Payload Encryption, Disk Encryption

    UEFI payload encryption key. • Please keep the key in a safe place. • Do not save any key in SPM workshop or in its child path. SPM default workshop is: /home/{user}/.local/share/spm_workshop/ SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 48 #1. Enter uefi-keys created in Step 1 $ cd uefi-keys #2. Create "uefi_keys.conf" with vim and open it $ vim uefi_keys.conf #3. Insert the following lines to uefi_keys.conf file and then save file: UEFI_PK_KEY_FILE="PK.key"; UEFI_PK_CERT_FILE="PK.crt"; UEFI_KEK_KEY_FILE="KEK.key"; UEFI_KEK_CERT_FILE="KEK.crt"; UEFI_DB_1_KEY_FILE="db_1.key"; SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 49 9. After the secured images are generated and marked as Done, press the Enter key to install the image to the device. 10.If the images are installed to the device successfully, the message Flash is successful will be displayed, otherwise an error message will be displayed. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 50: Revoking The Pkc Key

    4. If the SBK fuse on this device has been burned, input the absolute path of SBK key file. Press the Enter key. 5. If the OEMK1 or OEMK2 fuse on this device has been burned, input the absolute path of OEMK1/OEMK2 key file in KEY format and press the Enter key. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 51 10.If the PKC key is revoked successfully, the message Success to flash images to BX-35A will be displayed, otherwise the PKC key cannot be revoked. Note After the revoke procedure, SPM will clean the workshop and exit. Do not terminate the dialog manually. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 52: Expanding The Device

    Installing the M.2 module Introduction to the M.2 module Siemens uses the M.2 module to extend the Siemens IPC. You can use the M.2 module produced by Siemens or other third-party suppliers. The device provides three M.2 interfaces for M.2 B Key / E Key / M Key modules. The M.2 modules can be connected to the interface slot X100, X101, or X103 on the motherboard.
  • Page 53 M.2 module. Get the cable of the M.2 module installation accessory out of the housing through reserved antenna holes. Note: There are four caps on each reserved antenna holes. Remove the caps from inside. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 54: Inserting The Nano Sim Card

    Carefully insert the Nano SIM card into the card holder without applying excess force. Disconnect the device from the power supply. Remove the retaining four screws on the rear cover of the device. Lift up the rear cover. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 55: Installing The Ssd

    To ensure the heat dissipation and the performance of NVMe SSD, the BX-35A uses a heat sink to secure the SSD. The heat sink accessory is designed for 2280 SSD, and it is also compatible for 2242 SSD. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 56 Secure the SSD module with a screw. Note: Ensure the SSD module board is located between head and spacer of assembly screw. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 57: Installing The Som

    • A SoM (System on Module) that is approved for industrial applications. • T8 screwdriver and T10 screwdriver Procedure - installing the SoM Remove the four retaining T10 screws on the rear cover of the device, and lift up the rear cover. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 58 Remove the T8 screw and release the SSD. Remove the four T10 screws and release the panel. Turn to the back panel of the device and remove the two SW4.5 screw. Remove the four T10 screws and release the panel. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 59 Note: Make sure the side buckles of the bracket are secured. Remove the tapes on the TIMs attached on the top housing. Follow the above steps in reverse order to install the SOM. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 60: Maintaining And Repairing The Device

    Maintaining and repairing the device Maintenance To maintain high system availability, Siemens recommends preventative replacement of the back-up battery at replacement intervals of 3 years. Repair information Carrying out repairs Only qualified personnel are permitted to repair the device. Contact your local representative, see section "Service and support (Page 93)".
  • Page 61: Replacing The Backup Battery

    – Rated voltage: 3 V DC – Max abnormal charging current: 5 mA • For any requirements on product maintenance, contact Siemens Technical support (Page 93). • Do not throw lithium batteries into fire, do not solder on the cell body, do not recharge, do not open, do not short-circuit, do not reverse polarity, do not heat above 100°C and...
  • Page 62 – Courant de charge anormal max.: 5 mA • Pour toute demande concernant la maintenance du produit, contactez le support technique (Page 93) Siemens. • Ne jetez pas au feu des piles au lithium, n'effectuez pas de soudage sur la pile, ne la rechargez pas, ne l'ouvrez pas, ne la court-circuitez pas, n'intervertissez pas les pôles, ne...
  • Page 63: Recycling And Disposal

    Contact a certified disposal service company for electronic scrap for environmentally sound recycling and disposal of your old devices, and dispose of the device according to the relevant regulations in your country. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 64: Technical Specifications

    The following shows the approvals that may be available. For the device itself, it is certificated as shown on the product label and package label. ISO 9001 certificate The Siemens quality management system for all production processes (Development, Production, Sales and Service of Automation Products, -Systems and -Solutions) meets the requirements of ISO 9001:2015 Certificate registration no.
  • Page 65 UL approval The following approvals are available for the device: • Underwriters Laboratories (UL) in accordance with Standard UL61010-1 and UL61010-2- 201, File E472609 • Canadian National Standard CAN/CSA No.61010-1-12 and CAN/CSA C22.2 No.61010-2- SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 66 DI FA TI COS TT P.O. Box 1963 D-92209 Amberg The UK Declaration of Conformity is also available for download from the Siemens Industry Online Support website under the keyword "Declaration of Conformity". This product meets the requirements of India certification.
  • Page 67 Responsible party for Supplier's Declaration of Conformity 西門子股份有限公司 臺北市 11503 南港區園區街 3 號 8 樓 電子郵件信箱: (Adscs.taiwan@siemens.com) WEEE label (European Union) Disposal instructions, observe the local regulations and the section "Recycling and disposal (Page 66) ". SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 68: Directives And Declarations

    The following abbreviations are commonly used for electrostatic sensitive devices: • ESD – Electrostatic sensitive device • ESD – Electrostatic Sensitive Device as a common international designation Electrostatic sensitive devices can be labeled with an appropriate symbol. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 69 These values conform to the specifications of IEC 61000-4-2. ① Synthetic materials ② Wool ③ Antistatic materials such as wood or concrete SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 70 This way, the discharge energy does not reach and damage the sensitive components. – Discharge your body electrostatically before you take a measurement at a module. Do so by touching grounded metallic parts. Always use grounded measuring instruments. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 71: Dimension Drawings

    Technical specifications 8.3 Dimension drawings Dimension drawings Wall mounting All dimensions in mm. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 72: General Technical Specifications

    Protection class III in accordance with IEC 61140 Degree of pollution Device is designed for environments with pollution degree 2 Quality assurance In accordance with ISO 9001 : In the event of low supply voltage, the buffer time is reduced. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 73 SOM (System on Processor and RAM • 6-Core NVDIA ARM v8.2 (64bit) Processor, 8GB Module) LPDDR5 • 8-Core NVDIA ARM v8.2 (64bit) Processor, 16GB LPDDR5 QSPI Flash 64 Mb on board QSPI flash SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 74: Ambient Conditions

    • 4 × DI + 4 × DQ CAN BUS (X11) 1× isolated CAN FD port : Siemens recommends that PoE Ethernet port only connect to the PD device and non-PoE ethernet device. Ambient conditions Climatic ambient conditions For permitted mounting positions, see section "Permitted mounting positions and mounting types (Page 23)“.
  • Page 75 5 to 8.4 Hz: 3.5 mm • 8.4 to 500 Hz: 9.8 m/s Shock resistance, tested in accordance with IEC 60068-2-27 Operation • 150 m/s², 11 ms Storage/transport • 250 m/s , 6 ms SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 76: Power Demand Of The Components

    1 × 30 W or 2 × 15 W or 4 × 7.5 W USB port max. load 6.5 W Orin NX modules • 20 W for 8GB • 25 W for 16GB SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 77: Hardware Descriptions

    Technical specifications 8.8 Hardware descriptions Hardware descriptions 8.8.1 Motherboard The following figures show the motherboard of the SIMATIC IPC BX-35A. Component/interface Description Meaning Ethernet 1 RJ45 POE optional Ethernet 2 RJ45 POE optional Ethernet 3 RJ45 POE optional Ethernet 4...
  • Page 78: External Interfaces

    CAN connector (X11) External • 1 x CAN BUS connector 8.8.2.2 Power supply Plug connector, 2-pin Name of interface on the device: X80 Assignment GND (M) DC 12-24 V (9 to 36 V DC) (L+) SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 79: Digital I/O Connector

    • sudo dmesg | grep DQ_n/DI_n (If GPIO is exported after startup) n refers to the number (0~3) for DI or DQ. General specifications and DI features Technical data Digital inputs Number of inputs Type Sink SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 80 8 A for 100 ms max. Overload protection Isolation (field side to logic) 500 V AC for 1 minute Switching rate Mechanical Electrical 10 Hz Resistive load/lamp load (Tungsten) 10 Hz Inductive load (pilot duty) 0.5 Hz SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 81: Usb

    Power out Data channel USB2 Input / output Data channel USB2 Input / output Ground – Data channel USB3 Input Data channel USB3 Input Ground – Data channel USB3 Output Data channel USB3 Output SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 82: Displayport

    Output Ground ML_Lane 3- DP data 3- Output CONFIG1 CONFIG1 CONFIG2 CONFIG2 AUX_CH+ Auxiliary channel+ Bidirectional Ground AUX_CH- Auxiliary channel- Bidirectional Hot Plug Detect Input Ground DP_PWR +3.3 V (Power switch) power out SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 83: Ethernet Port

    Orange light: Link – Orange Blink: Activity Off: No Link 8.8.2.7 Serial port D-sub socket, 9-pin, with screw lock Name of interface on the device: X30 COM RS 232 RS 422 RS 485 SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 84 Receive data - (I) for full-duplex mode Signal ground Assignment RS 485 Short description Meaning Data- Transmit / receive data - (I/O) for half-duplex mode Data+ Transmit / receive data+ (I/O) for half-duplex mode Signal ground SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 85: Can Port

    M.2 M Key (X103) Internal Support NVME SSD card through PCIe GEN4 ×4 8.8.3.2 M.2 interface M.2 E Key module Name of interface on the device: X100 Pin no. Signal Signal Pin no. 3.3V 3.3V SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 86 3.3V USB2_D_P_CONN 3.3V M.2 B Key module Name of interface on the device: X101 Pin no. Signal Signal Pin no. 3.3V 3.3V 3.3V CFG1 SUSCLK RESET# SIM_DETECT (optional) ANTCTL3 COEX_RXD ANTCTL2 COEX_TXD ANTCTL1 SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 87 USB_D- W_DISABLE# USB_D+ WWAN_PWR_OFF_N 3.3V 3.3V M.2 M Key module Name of interface on the device: X100 Pin no. Signal Signal Pin no. 3.3V 3.3V 3.3V SUSCLK_M2_MKEY PCIE0_CLK_P PCIE0_CLK_N PCIE0_CLKREQ_N PCIE0_RST_N PCIE0_TX0_P_C PCIE0_TX0_N_C SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 88 Technical specifications 8.8 Hardware descriptions M2M_ALERT_N PCIE0_RX0_P PCIE0_RX0_N PCIE0_TX1_P_C PCIE0_TX1_N_C PCIE0_RX1_P PCIE0_RX1_N PCIE0_TX2_P_C PCIE0_TX2_N_C PCIE0_RX2_P 3.3V PCIE0_RX2_N 3.3V 3.3V PCIE0_TX3_P_C 3.3V PCIE0_TX3_N_C SSD_ACTIVE_LED PLN# PCIE0_RX3_P PCIE0_RX3_N 3.3V 3.3V SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 89: Technical Support

    You can find additional information and support for the products described on the Internet at the following addresses: • Technical support (https://support.industry.siemens.com) • Support request form (https://support.industry.siemens.com/cs/my/src) • After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) • Documentation for SIMATIC Industrial PCs (https://support.industry.siemens.com/cs/us/en/view/109744171) • Your local representative (https://www.automation.siemens.com/aspa_app) •...
  • Page 90: Troubleshooting

    USB device does not respond The USB ports are not correctly You need to install the USB device drivers for the supported. required operating system. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 91: Digital I/O And Can Terminal Block

    • Type of wire: – Solid – Flexible – Stranded • Clamping range: – without plastic collar ferrule: 0.2 mm² to 1.5m² – with plastic collar ferrule: 0.2 mm² to 0.75m² • A screwdriver SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 92 2. Put the wire into the wire entry. 3. Release the button. Procedure for wiring release Follow the above steps in reverse direction to release the wire. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 93: Markings And Symbols

    Disconnect the power plug before Opening for Kensington lock opening Attention ESD (Electrostatic sensitive Warning of hot surface device) Operator controls Symbol Meaning Symbol Meaning On/off switch, without electrical Eject CD/DVD isolation On/off switch, without electrical isolation SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 94: Certificates, Approvals And Markings

    CE markings for European countries Marking of Federal Communications Commission for the USA EFUP (Environment Friendly Use Approved for Korea Period) marking for China Test mark of the Underwriters Disposal information, observe the Laboratories local regulations. SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 95: Interfaces

    DVI-D interface Line In LAN interface, not approved for Line Out connecting WAN or telephone Serial port Microphone input USB port Universal Audio Jack USB 2.0 high-speed port Headphone output USB 3.0 super-speed port SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 96: List Of Abbreviations

    Personal computer Printed circuit board PCIe Peripheral Component High-speed serial, differential full-duplex PtP Interconnect express interface with high data rate. PELV Protective extra-low voltage Programming device Power over Ethernet Power Sourcing Equipment SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 97 Safety Extra Low Voltage Safety extra low voltage Secure Hash Algorithm UEFI Unified Extensible Firmware Interface Unique ID Underwriters Laboratories Inc. US organization for testing and certification according to national or binational standards. Universal Serial Bus SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 98 Motherboard EAC, 69 Technical features, 80 ESD, 71 Mounting ESD Directive, 71 Wall, 27 Ethernet port, 81 Mounting on a standard rail, 75 Expansion slot, 77 Mounting position, 23 Mounting type, 23, 24 SIMATIC IPC BX-35A Operating Instructions, 04/2024, A5E52539873-AA...
  • Page 99 RAM, 76 Rating plate, 22 RCM, 69 RCM Australia/New Zealand, 69 Repairs, 63 Safety information Storage, 22 Transportation, 22 Siemens Support Package, 33 SPM, 33, 33 Downloading SPM, 34 Installing SPM, 34 Installing, 59 Removing, 60 Static electricity Protective measures, 73...

Table of Contents