Page 3
English 45L (12 Gallon) Portable Wet/Dry Vacuum DWV112 Congratulations! You have chosen a D WALT product. Years of experience, thorough product development and innovation make D WALT one of the most reliable partners for professional machine users. Definitions: Safety Alert Symbols and Words This instruction manual uses the following safety alert symbols and words to alert you to hazardous situations and your risk of personal injury or property damage.
Page 4
English 3) Personal Safety WARNING! Read all safety warnings and all instructions. Failure to follow the warnings and a ) Stay alert, watch what you are doing and use instructions may result in electric shock, fire and/or common sense when operating a machine. Do serious injury.
Page 5
English machine repaired before use. Many accidents are dust mask if area operation is dusty. ALWAYS WEAR caused by poorly maintained machines. CERTIFIED SAFETY EQUIPMENT:: f ) Keep cutting machines sharp and clean. Properly • ANSI Z87.1 eye protection (CAN/CSA Z94.3), maintained cutting machines with sharp cutting •...
Page 6
If an extension cord is to be used outdoors it must be marked with the suffix W-A or W following the cord This portable wet/dry vacuum DWV112 is designed for type designation. For example – SJTW-A to indicate it is professional applications.
Page 7
English Accessory Bag Holder Bracket Assembly Fig. E (Fig.C) Attach 2 accessory bag holder brackets to tank with 4 self- tapping screws provided. Fig. C Activation Position OPERATION WARNING: Always observe the safety instructions and applicable regulations. WARNING: To reduce the risk of serious personal injury, turn unit off before making any adjustments or removing/installing attachments or accessories.
Page 8
DEWALT distributor. When picking up large amounts of 3. To remove the filter for cleaning, turn the filter knob liquid we recommend that the filter be removed. If the...
Page 9
English ACCOMPLISHED WITH A WARM SOLUTION OF SOAP to its original position. To continue use, plug the cord into AND WATER. the wall outlet and turn the unit on. 3. This wet/dry vac is equipped with a float mechanism Blowing Operation which will rise automatically to cut off the airflow when the liquid in the tank reaches a predetermined level.
Page 10
TEChniCAl DATA WARNING: Do not remove filter cage and float. The float prevents water from entering the impeller and DWV112 damaging the motor. The cage prevents fingers from Voltage touching the moving impeller.
Page 11
English TROUBLESHOOTING PROBLEM POSSIBLE SOLUTION Check power cord, plugs and outlet. Motor does not run Ensure the on/off switch is in the ON position (I). Remove blockages in the nozzle, extension wand, hose or filter. Replace the paper or fleece bag. Suction capacity decreases Check for proper installation of the filter.