Table 1-6. System Messages (continued)
Message
No boot sector on hard
drive
No timer tick interrupt
Not a boot diskette
PCIe Degraded Link Width
Error: Embedded
Bus# nn /Dev# nn /Func n
Expected Link Width is n
Actual Link Width is n
PCIe Degraded Link Width
Error: Slot n
Expected Link Width is n
Actual Link Width is n
PCIe Fatal Error caused a
system reset: Slot n
or
Embedded
Bus# nn /Dev# nn /Func n
Please check the system
event log for details.
PCI BIOS failed to
install
Plug & Play Configuration
Error
Causes
Incorrect configuration settings in
System Setup program, or no
operating system on hard drive.
Faulty system board.
No operating system on diskette.
Faulty or improperly installed PCIe
card in the specified slot.
Faulty or improperly installed PCIe
card in the specified slot.
Faulty or improperly installed PCIe
card in the specified slot.
PCI device BIOS (Option ROM)
checksum failure is detected during
shadowing. Loose cables to
expansion card(s); faulty or
improperly installed expansion card.
Error encountered in initializing
PCI device; faulty system board.
Corrective Actions
Check the hard-drive configuration
settings in the System Setup program.
See "Using the System Setup Program"
on page 23. If necessary, install the
operating system on your hard drive.
See your operating system
documentation.
See "Getting Help" on page 95.
Use a bootable diskette.
Reseat the PCIe card in the specified
slot number. See "Installing an
Expansion Card" on page 44. If the
problem persists, see "Getting Help"
on page 95.
Reseat the PCIe card in the specified
slot number. See "Installing an
Expansion Card" on page 44. If the
problem persists, see "Getting Help"
on page 95.
Reseat the PCIe card in the specified
slot number. See "Installing an
Expansion Card" on page 44. If the
problem persists, see "Getting Help"
on page 95.
Reseat the expansion cards. Ensure
that all appropriate cables are securely
connected to the expansion cards. If
the problem persists, see
"Troubleshooting an Expansion Card"
on page 80.
Install the NVRAM_CLR jumper and
reboot the system. See Figure 6-1 for
jumper location. If the problem
persists, see "Troubleshooting an
Expansion Card" on page 80.