FCS Characteristics
not known to both of them. FCS operations can be done only on those switches that are visible in the VSAN.
M2 can send FCS requests only for VSAN 2 even though S3 is also a part of VSAN 1.
Figure 77: FCSs in a VSAN Environment
FCS Characteristics
FCSs have the following characteristics:
• Support network management including the following:
• Support TE ports in addition to the standard F and E ports.
• Can maintain a group of nodes with a logical name and management address when a platform registers
• SNMP manager can query FCSs for all IEs, ports, and platforms in the fabric.
Cisco Nexus 5000 Series Switch CLI Software Configuration Guide
662
◦ N port management application can query and obtain information about fabric elements.
◦ SNMP manager can use the FCS management information base (MIB) to start discovery and obtain
information about the fabric topology.
with it. FCSs maintain a backup of all registrations in secondary storage and update it with every change.
When a restart or switchover happens, FCSs retrieve the secondary storage information and rebuild its
database.
Configuring Fabric Configuration Servers
OL-16597-01