PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications Overview 1.1 This Functional Specification defines communication functions for PLC-WL2500 / WL2501. 1.2 Compatible to Firmware Ver. 1.x of the projector. 1.3 Most commands can be used to control projector remotely from PC by RS-232C. Therefore, the commands are defined as Expand Serial Commands.
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications Notes for communication 1. Expand Serial Command is defined as one command / one line that starts with “C” and ends with carriage return (0x0D) 2. There are two types of commands: Functional Execution Command and Status Read Command.
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 5. Functional Execution Command Table 5.1 Image Command Table Execute command Item CF_BRIGHT_%1[CR] Set Brightness value CF_CONT_%1[CR] Set Contrast value CF_COLOR_%1[CR] Set Color value CF_TINT_%1[CR] Set Tint value CF_SHARP_%1[CR] Set Sharpness value CF_GAMMA_%1[CR] Set Gamma value CF_WBAL-R_%1[CR]...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 5.4 Screen Command Table Execute command Item CF_SCREEN_%1[CR] Select Screen size CF_DZCENT_%1[CR] Cancel Digital Zoom mode CF_KEYSTONE_%1[CR] Set Keystone CF_KYSTNMODE_%1[CR] Set Keystone Store mode CF_VSCALE_%1[CR] Set value of Vertical scale CF_VPOS_%1[CR] Set value of Vertical position CF_HSCALE_%1[CR] Set value of Horizontal scale CF_HPOS_%1[CR]...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 5.8 Other Command Table Execute command Item Behave the same as corresponding key of the projector / CF_KEYEMU_%1[CR] remote control. CF_MENU_%1[CR] Switch ON/OFF of each Menu. CF_POWER_%1[CR] Switch ON/OFF of Power. CF_FREEZE _%1[CR] Set Freeze function.
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 6. Status Read Command Table 6.1 Image Status Read Command Table Status read command Item CR_BRIGHT[CR] Get Brightness value CR_CONT[CR] Get Contrast value CR_COLOR[CR] Get Color value CR_TINT[CR] Get Tint value CR_SHARP[CR] Get Sharpness value CR_GAMMA[CR] Get Gamma value...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 6.5 Screen Status Read Command Table Status read command Item CR_SCREEN[CR] Get selected screen size CR_KYSTNMODE[CR] Get setting status of Keystone Store mode CR_VSCALE[CR] Get setting status of Vertical Scale CR_VPOS[CR] Get setting status of Vertical Position CR_HSCALE[CR] Get setting status of Horizontal Scale CR_HPOS[CR]...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications CR_FILH[CR] Get Filter used time CR_FILREPL[CR] Get the information for Filter replacement time CR_FILTIMER[CR] Get time when Filter warning OSD is displayed 6.9 Other Status Read Command Status read command Item CR_STATUS[CR] Get setting status of Projector behavior CR_SIGNAL[CR] Get Signal Status if there is a signal or not...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 7. Error Code Table Error Code Details -When the received data cannot be decoded -Parameter determination error (digit number error, including invalid value, etc.) When the function selected is not available under current condition. ex) When receiving signal-related commands while no signal is entered Selected value is out of range (Not reflected) Command mismatched to Hardware (command for Optional function...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 8. Functional Execution Command 8.1 Format PC issues commands in format as below: Pattern1 : “CF_COMMAND” [CR] Pattern2 : “CF_COMMAND_”%1 [CR] CF_ : Header COMMAND : Character line %1 : Parameter (Character line) _ : Space (To separate COMMAND and Parameter) The projector decodes the received command and when it is ready to receive the next command, it returns the response.
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 8.4 Image Command 8.4.1 CF_BRIGHT Command Command "CF_BRIGHT_%1”[CR] "000~063” --------------- Directly select Brightness setting value "UP” ----------------------- Current Brightness setting value + 1 "DN” ----------------------- Current Brightness setting value – 1 Set Brightness value of user control The value set by this command will not be saved to projector.
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 8.4.5 CF_SHARP Command Command “CF_SHARP_%1”[CR] “000~015” ---------------- Directly select Sharpness setting value “UP” ------------------------ Current Sharpness setting value + 1 “DN” ------------------------ Current Sharpness setting value - 1 Set Sharpness value of user control The value set by this command will not be saved to projector.
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 8.4.8 CF_COLTEMP Command Command “CF_COLTEMP_%1”[CR] “000” ------ Xlow “001” ------ Low “002” ------ Mid “003” ------ High Set Color Temperature. (Available only in the normal Power ON status) The value set by this command will not be saved to the projector. Therefore, when Details turning into Standby status or ALL is OFF, the value returns to original setting.
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 8.4.11 CF_IMAGE Command Command “CF_IMAGE_%1”[CR] “DYNAMIC” ------ Dynamic (Fixed value to enable projection with a sharp, powerful picture tone) “STAND” ---------- Standard (Image adjust value is set to factory default) “REAL” ------------ Real (Fixed value to display graphic image with natural tone) “CINEMA”...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 8.5 PC Adjust Control Command 8.5.1 CF_FSYNC Command Command “CF_FSYNC_%1”[CR] “0000~0031” --------------- Directly select Fine Sync setting value “UP” -------------------------- Current Fine Sync setting value + 1 “DN” -------------------------- Current Fine Sync setting value - 1 Set Fine Sync value of PC signal The value set by this command will not be saved to projector.
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 8.5.4 CF_H – POS Command Command “CF_H-POS_%1”[CR] “0000~nnnn” --- Directly select Horizontal Position setting value “nnnn” shows maximum value, it is current Total Dots value - Display Dots value “UP” -------------- Current Horizontal Position setting value + 1 “DN”...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 8.5.7 CF_DLINE Command Command “CF_DLINE_%1”[CR] “0100”~”nnnn” --- Directly select Display Line setting value “nnnn” shows maximum value, it is current Total Line value – Vertical Position value “UP” -------------- Current Display Line setting value + 1 “DN”...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 8.6.5 CF_INPUT3 Command Command “CF_INPUT3_%1_”[CR] “HDMI” ------------------ Select HDMI Select HDMI Input and source specified in %1 at once. Details This command is available in normal Power ON status. Acceptable “000”[CR] Response Unacceptable “Error Code”[CR] 8.6.6...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 8.7.3 CF_KEYSTONE Command Command “CF_KEYSTONE_%1”[CR] “UP” ------------- Correct Keystone distortion to reduce upper part of image “FUP” ----------- Correct Keystone distortion to reduce upper part by 2steps “DN” ------------- Correct Keystone distortion to reduce lower part of image “FDN”...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 8.8 Lamp Command 8.8.1 CF_LAMPH Command Command “CF_LAMPH_%1”[CR] “RST” Reset Lamp use time counter. Details This command is available in normal Power ON status. Acceptable “000”[CR] Response Unacceptable “Error Code”[CR] 8.8.2 CF_LAMPMODE Command Command “CF_LAMPMODE_%1”[CR] “NORMAL”...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 8.9 Sound Command 8.9.1 CF_VOLUME Command Command “CF_VOLUME_%1”[CR] “000-063” -------------------------- Directly select Volume setting value “UP” --------------------------------- Current Volume setting value +1 “DN” --------------------------------- Current Volume setting value -1 Control Volume value The same operation of Volume Up/Down as projector and RC, and directly select Volume setting value.
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 8.10.3 CF_AUTOSETUPPCADJ Command Command “CF_AUTOSETUPPCADJ_%1”[CR] “ON” ------------------- Set Auto PC ADJ. function to ON “OFF” ------------------ Set Auto PC ADJ. function to OFF Set/Cancel Auto PC adj. function This command is available in normal Power ON status. Details Note) It is unable to set both PC ADJ.
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 8.10.9 CF_CEIL Command Command “CF_CEIL_%1”[CR] “ON” ------------------------ Set Ceiling to ON “OFF” ----------------------- Set Ceiling to OFF Set/Cancel Ceiling setting. The value set by this command is stored in EEPROM and its setting is effective Details even after ALL is OFF This command is available in normal Power ON status.
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 8.10.13 CF_HDMI SOUND Command Command “CF_HDMI SOUND_%1”[CR] “HDMI” ----------------------- Select PCM sound (Digital sound) “EXTERNAL” ------------- Select External sound input Select sound mode of HDMI setup. The status set by this command is stored in EEPROM and its setting is effective Details after ALL is OFF This command is available in normal Power ON status.
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 8.10.17 CF_P-MANETIME Command Command “CF_P-MANETIME_%1”[CR] “01” ~ ”30” ----------------------- Directly select setting time by the minute “UP” ------------------------------- Plus one minute (01 → 02 → ÿ e ÿ e ÿ e → 30 → 01) ÿ...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 8.10.21 CF_PTIME Command Command “CF_PTIME_%1”[CR] “001” ~ “180” -----------Directly specify the time by minutes. Set Countdown timer for P-timer function. The status set by this command is stored in EEPROM and its setting is effective Details after ALL is OFF This command is available in normal Power ON status.
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 8.10.24 CF_RCODE Command Command “CF_RCODE_%1”[CR] "001” --------------------------- Select Code1 "002” --------------------------- Select Code2 “UP” --------------- Switch Code setting of Remote Control forward “DN” -------------- Switch Code setting of Remote Control backward Note) “UP” and “DN” behave the same. Select Code of Remote Control The status set by this command is stored in EEPROM and its setting is effective Details...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 8.10.27 CF_FANMODE Command Command “CF_FANMODE_%1”[CR] “L1” ---------------------------- Set Fan Mode to L1 “L2” ---------------------------- Set Fan Mode to L2 Switch Fan Mode When L1 is selected, fan noise after POWER OFF is louder. When L2 is selected, fan noise after POWER OFF becomes quiet.
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 8.10.31 CF_FILH Command Command “CF_FILH_%1”[CR] “RST” ---------------Reset Filter used time Details Reset filter used time Acceptable “000”[CR] Response Unacceptable “Error Code”[CR] 8.10.32 CF_FDEFAULT Command Command “CF_FDEFAULT_%1”[CR] “RST” Set the value to Factory Default Details This command is available in normal Power ON status.
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 8.11 Other Command 8.11.1 CF_KEYENU Command Command “CF_KEYENU_%1”[CR] “RIGHT” ------------------------- Shift Pointer on OSD Menu to right “LEFT” --------------------------- Shift Pointer on OSD Menu to left “UP” ------------------------------ Shift Pointer on OSD Menu to right “DN”...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 8.11.4 CF_FREEZE Command Command “CF_FREEZE_%1”[CR] “ON” ------------------------ Set Freeze to ON “OFF” ----------------------- Set Freeze to OFF “UP” ------------------------------ Switch setting (On → Off → On → ÿ e ÿ e ÿ e ) “DN”...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 9. Status Read Command 9.1 Format PC issues commands in format as below: “CR_Command” [CR] Command: Character Line When projector receives the appropriate command, it returns a character line as the required data “000ÿ...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 9.4 Image Status Read Command 9.4.1 CR_BRIGHT Command Command “CR_BRIGHT”[CR] Details Get Brightness value of user control Acceptable “000_ÿ ÿ A ”[CR] Response “000”~“063” Unacceptable “Error code”[CR] 9.4.2 CR_CONT Command Command “CR_CONT”[CR] Details Get Contrast value of user control Acceptable...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 9.4.7 CR_WBAL – R Command Command "CR_WBAL-R”[CR] Details Get White Balance Red value of user control Acceptable “000_%a”[CR] Response “000”~“063” Unacceptable “Error code”[CR] 9.4.8 CR_WBAL – G Command Command "CR_WBAL-G”[CR] Details Get White Balance Green value of user control Acceptable “000_%a”[CR] Response...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 9.4.12 CR_PROGV Command Command “CR_PROGV”[CR] Details Get setting status of Progressive scan Acceptable “000_%a”[CR] “L1” ----------------- Progressive Mode L1 is selected “L2” ----------------- Progressive Mode L2 is selected Response “FILM” -------------- Progressive Model FILM is selected “OFF”...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 9.5 PC Adjust Status Read Command 9.5.1 CR_FSYNC Command Command "CR_FSYNC”[CR] Details Get Fine Sync value Acceptable “000_%a”[CR] Response “0000”~“0031” Unacceptable “Error Code”[CR] 9.5.2 CR_TDOTS Command Command “CR_TDOTS”[CR] Details Get Total Dots value Acceptable “000_%a”[CR] “nnnn”~“mmmm”...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 9.6 Video Status Read Command 9.6.1 CR_SERSYS Command Command “CR_SERSYS”[CR] Get currently selected signal Details Returns auto-detected signal in Auto mode Only available for Video input. (N/A when Input is computer) Acceptable “000_%a”[CR] “1080I60”...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 9.7.9 CR_SYSLIST Command Command “CR_SYSLIST”[CR] Details Get selectable System titles Acceptable “000_%1_%2_..._%x” [CR] - When Input is PC-Analog “XGA1” ------------ XGA1is selectable “1080I ” ----------- 1080i is selectable Projector does not return Auto, Mode 1-10 When there is no signal, it returns Error Code “101”...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 9.9 Lamp Status Read Command 9.9.1 CR_LAMPREPL Command Command “CR_LAMPREPL”[CR] Details Get information of Lamp Replacement time Acceptable “000_%1”[CR] “1Y” -------------------------- Over lamp replacement time “1N” -------------------------- Within lamp replacement time “1” means the number of lamps. Response (1 lamp model→...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 9.9.5 CR_LAMPMSTS Command Command “CR_LAMPSTS”[CR] Details Get Lighting status of lamp Acceptable “000_%1”[CR] “ÿ N **** ” A number of * should be among 1-4. First character shows how many lamps are incorporated in projector.
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 9.11.4 CR_BACKGND Command Command “CR_BACKGND” [CR] Details Get setting status of Screen for no signal Acceptable “000_%1” [CR] “BLUE” -------------------------------- Blue Back is selected Response “USER” ------------------------------- User is selected “BLACK” ------------------------------ Black Back is selected Unacceptable “Error Code”...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 9.11.9 CR_SCREENASPECT Command Command “CR_SCREENASPECT”[CR] Details Get status of Screen aspect Acceptable “000_%1”[CR] “43MODE” ÿ e ÿ e ÿ e ÿ e ÿ e ÿ e ÿ e Select 4ÿ 3 mode Response “169MODE”...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 9.11.14 CR_P-MANE Command Command “CR_P-MANE”[CR] Details Get Power management setting status Acceptable “000_%a”[CR] “OFF” -------------------------- Power Management is OFF Response “READY” ---------------------- Power Management is Ready “SHUTDOWN” ---- Power Management is set to Shut Down mode Unacceptable “Error code”[CR] 9.11.15 CR_P-MANETIME Command...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 9.11.24 CR_KEYDIS Command Command “CR_KEYDIS”(CR) This command is available to models with top panel buttons only. Details Get disability status of RC/Projector keys (valid or invalid) Acceptable “000_%a”[CR] “NONE” -------------------------- RC / Projector keys are valid Response “RC”...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 9.11.29 CR_DELAYCTRL Command Command “CR_DELAYCTRL”[CR] Details Get setting status of Video delay control Acceptable “000_%1”[CR] “ON” ----------------------- Video delay control is active Response “OFF” ---------------------- Video delay control is inactive Unacceptable “Error Code”[CR] 9.11.30 CR_FILH Command Command “CR_FILH”[CR]...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 9.12 Other Status Read Command 9.12.1 CR_STATUS Command Command “CR_STATUS”(CR) Get status of Projector behavior. Details This command affects the same as ”CR0” of Basic Serial command, but this has an error code. Acceptable “000_%1”[CR] “00”= Power ON...
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 9.12.5 CR_TEMPWARN Command Command “CR_TEMPWARN”[CR] Get the temperature inside a projector and its condition if it is abnormal temperature or close to abnormal temperature Details If there are several sensors installed, it is possible to get information from all the sensors at once.
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 9.12.6 CR_TEMP Command Command "CR_TEMP”[CR] Get current temperature inside a projector. Details If there are several sensors installed, it is possible to get information from all the sensors at once. Acceptable “000_%1_%2_%3”[CR] %1= Sensor 1 temperature (Outside temperature) %2= Sensor 2 temperature (Inside temperature1) %3= Sensor 3 temperature (Inside temperature2)
PLC-WL2500 / WL2501 Expand Serial Command Functional Specifications 9.12.7 CR_TEMPFAIL Command Command "CR_TEMPFAIL”[CR] Get the temperature inside a projector when abnormal temperature occurs. Details If there are several sensors installed, it is possible to get information from all the sensors at once. Acceptable “000_%a_%b_%c”[CR] %a ------------------ Sensor 1 temp.