Operating and installation instructions Cooker hood DA 186 en - GB To avoid the risk of accidents or damage to this appliance, it is essential to read these instructions before it is installed M.-Nr. 07 623 170 and used for the first time.
Caring for the environment Disposal of the packing material Disposal of your old appliance The transport and protective packing Electrical and electronic appliances has been selected from materials which often contain materials which, if are environmentally friendly for handled or disposed of incorrectly, disposal, and should be recycled.
Any other usage is not supported by requirements. Inappropriate use the manufacturer and could be can, however, lead to personal injury dangerous. Miele cannot be held liable and damage to property. for damage resulting from incorrect or improper use or operation.
Technical safety Installation, maintenance and repairs may only be carried out by a Before installation, check the cooker Miele authorised person in accordance hood for visible signs of damage. with current national and local safety Under no circumstances should you regulations.
Page 6
Warning and Safety instructions Do not connect the appliance to the Using at the same time as other mains electricity supply by a heating appliances that depend on multi-socket unit or an extension lead. the air from the room These do not guarantee the required safety of the appliance (e.g.
Warning and Safety instructions Correct use In order to ensure safe operation, and to prevent gases given off by the Never use an open flame beneath heating appliances from being drawn the cooker hood. To avoid the danger back into the room when the cooker of fire, do not flambé...
All ducting, pipework and fittings into the appliance and hindering its must be of non-flammable material. smooth operation. These can be obtained from the Miele The filters should be regularly Spare Parts department or from cleaned or changed as appropriate.
No exchange of The charcoal filters are available to room and outside air can take place. order through your Dealer or the Miele Spare Parts Dept (see back page for When the cooker hood is switched on,...
Guide to the appliance / Operation Recirculation grille It is advisable to run the fan for a few (only for recirculation mode) minutes after cooking has finished to neutralise any lingering odours in the Exhaust connection air, whether you are using air extraction Adjustable bracket or recirculation mode.
Cleaning and care A range of Miele branded cleaning and Avoid: conditioning products is available to – cleaning agents containing soda, order from Miele (see back page for acids, chlorides or solvents, details) or via the internet at www.miele-shop.com. – abrasive cleaning agents, e.g.
65°C programme, ensuring the spray arm is not obstructed. If a Miele dishwasher is being used, select the Sensor wash programme. ^ Use a mild dishwasher detergent.
Cleaning and care Charcoal filters Important: For better access, the vapour canopy If the cooker hood is being used on can be removed completely. recirculation mode, two DKF 14-1 ^ Open the vapour canopy charcoal filters must be fitted behind the grease filters.
Cleaning and care Changing a halogen lamp Before any cleaning or maintenance work, disconnect the cooker hood from the mains supply. Exercise caution when changing halogen lamps. They get very hot during use, and remain hot for some time after being switched off. Do not touch the surface directly when ^ Unscrew the two fixing screws on the changing a lamp, as grease...
For information on the appliance under guarantee, please contact: guarantee specific to your country – your Miele Dealer please contact Miele. See back cover for contact details. In the U.K. your appliance is – the Miele Service Department guaranteed for 2 years from the date of (see back cover for contact details).
650 mm, unless a greater distance is specified by the manufacturer. If this cooker hood is installed above a Miele Wok CS 1028 CombiSet appliance, a minimum safety distance of 760 mm must be maintained between the burner and the lower edge of the cooker hood.
Installation Before installation, it is important to read the information given on the following pages as well as the Warning and Safety instructions at the beginning of this booklet. This is particularly crucial when using the cooker hood at the same ^ Take the filter out and then remove time as a heating appliance that the protective foil from around the...
Page 19
Installation Depth adjustment Fitting the cooker hood to the wall ^ Cut the drilling template for the wall fixings to size, and position against the wall. The top edge of the template indicates the top edge of the appliance. It must be at least H = 1100 mm in order to comply with the safety height required ^ The depth of the unit "T"...
Page 20
Installation ^ Position the vapour canopy with the furniture door front fitted, and close it. ^ The recirculation grille must be removed when the hood is used in extraction mode. The movement of the vapour canopy can be adjusted if necessary, for instance where a heavy furniture door is fitted.
Page 21
Installation Height adjustment Securing the appliance to neighbouring wall units or fitting side panels ^ Remove the vapour canopy. ^ Remove the grease filters. ^ Using the screws at the back of the adjustable brackets, align the cooker ^ Secure the cooker hood to the hood height with that of neighbouring neighbouring units, or fit the side units.
Page 22
Installation With air extraction: If the on-site ventilation system does not have a non-return flap, one of the two non-return flaps supplied (for C 150 mm or C 120 mm ducting) must be fitted. ^ Finally refit the grease filters. –...
Electrical connection If the switch is not accessible after All electrical work should be installation (depending on country), an undertaken by a suitably qualified additional means of disconnection must and competent person in strict be provided for all poles. accordance with current national For extra safety it is advisable to install and local safety regulations a residual current device (RCD) with a...
Connection for air extraction – Where ducting is horizontal, it must Important: To avoid the danger of be laid to slope away at at least 1 cm toxic fumes, please observe the per metre. Warning and Safety instructions. This is to ensure that condensate This is especially crucial when using cannot drain back into the cooker the cooker hood at the same time as...