(8) How to move the pickup from the inner circumference to the outer circumference
<Hints>
The TS Mech has two different pickup (hereinafter referred to as "PU") positions: the PU stop position after the power for the main unit
is turned off and the PU fixed position on the service parts. The former has its PU stopped on the inner circumference, and the latter has
its PU stopped on the outer circumference. Thus when placing the TS Mech detached form the product in the container for transporta-
tion, it is required to move the PU stop position from the inner circumference to the outer circumference manually.
The condition of TS Mech Pickup positioned at inner /outer circumference
PU stopped at inner circumference
(At main unit power OFF with Disc
Cover open)
<Check Points>
1) Tool Reauired
Tweezers made of non-magnetic material whose ends are not sharp, or a bar-like article (made of plastic or wood)
2) Moving method
Slowly push the section shown in the figure (orange-colored section) outward. Pushing the other section may damage the pickup
section. When the pickup has reached the outer circumference, do not keep on pressing further.
PU stopped at the outer circumference
(Packed in the service part container)
Fig. 10
14
DC10 E, DC20 E
SERVICE HINTS