This section lists the physical specifications.
Dimensions
Width: 310 mm (12.2 in.)
Height: 85 mm (3.35 in.)
Depth: 358 mm (14.1 in.)
Weight
Minimum configuration as shipped: 7.3 kg (16 lbs)
Maximum configuration: 8.5 kg (18.7 lbs)
Environment
Air temperature:
Operating at 0 - 3000 ft (914.4 m): 10° to 35°C (50°
to 95°F)
Operating at 3000 ft - 7000 ft (2134 m): 10° to 32°C
(50° to 89.6°F)
Non-operating: 10° to 43°C (50° to 110°F)
Humidity:
Operating: 8% to 80%
Non-operating: 8% to 80%
Transit: 8% to 90%
Maximum altitude: 7000 ft (2133.6 m)
Electrical input
Input voltage:
Low range:
Minimum: 100 V ac
Maximum: 127 V ac
Input frequency: 50/60 Hz
Voltage switch setting: 115 V ac
High range:
Minimum: 200 V ac
Maximum: 240V ac
Input frequency: 50/60 Hz
Voltage switch setting: 230 V ac
Input kilovolt-amperes (kVA) (approximate):
Minimum configuration as shipped: 0.10 kVA
Maximum configuration: 0.24 kVA
40
Hardware Maintenance Manual
Heat output (approximate) in British thermal units (Btu)
per hour:
Minimum configuration: 239 Btu/hr (70 watts)
Maximum configuration: 768 Btu/hr (225 watts)
Airflow
Approximately 45 cubic meters (16 cubic feet) per
minute maximum
Acoustical Noise Emissions
Declared Sound Power Levels
Idle: 4.0 bels
Operating: 4.3 bels
Average sound-pressure levels
At operator position - 0.5 meters (1.65 ft)
Idle: 29 dBA
Operating: 34 dBA
At bystander position - 1 meter (3.3 ft)
Idle: 26 dBA
Operating: 29 dBA
Note: These levels were measured in controlled
acoustical environments according to the procedures
specified by the American National Standards Institute
(ANSI) S12.10 and ISO 7779 and are reported in
accordance with ISO 9296. Actual sound-pressure levels
in a given location might exceed the average values
stated because of room reflections and other nearby noise
sources. The declared sound-power levels indicate an
upper limit, below which a large number of computers
will operate.