Parameter list
PNU
Description
P662
Source for control word 1, bit4
*
(0=set ramp-function generator to zero, 1=enable ramp-function generator)
BDS
(G180)
P663
Source for control word 1, bit5
*
(0=ramp-function generator stop, 1=ramp-function generator start)
BDS
(G180)
P664
Source for control word 1, bit6
*
(0=enable setpoint, 1=disable setpoint)
BDS
(G180)
P665
1st source for control word 1, bit7
*
(0 → 1 transition=acknowledge; ORed with 2
BDS
(G180)
P666
2nd source for control word 1, bit7
*
(0 → 1 transition=acknowledge; ORed with 1
BDS
(G180)
P667
3rd source for control word 1, bit7
*
(0 → 1 transition=acknowledge; ORed with 1
BDS
(G180)
P668
Source for control word 1, bit8
*
(1=inching bit0)
BDS
(G180)
P669
Source for control word 1, bit9
*
(1=inching bit1)
BDS
(G180)
P671
Source for control word 1, bit11
*
(0=pos. direction of rotation disabled, 1=pos. direction of rotation enabled)
BDS
(G180)
P672
Source for control word 1, bit12
*
(0= neg. direction of rotation disabled, 1= neg. direction of rotation enabled)
BDS
(G180)
P673
Source for control word 1, bit13
*
(1=raise motorized potentiometer)
BDS
(G180)
P674
Source for control word 1, bit14
*
(1=lower motorized potentiometer)
BDS
(G180)
P675
Source for control word 1, bit15
*
(0=external fault, 1=no external fault)
BDS
(G180)
Control word 2
P676
Source for control word 2, bit16
*
(select function data set bit 0)
BDS
(G181)
P677
Source for control word 2, bit17
*
(select function data set bit 1)
BDS
(G181)
P680
Source for control word 2, bit20
*
(select fixed setpoint 0)
BDS
(G181)
P681
Source for control word 2, bit21
*
(select fixed setpoint 1)
BDS
(G181)
11-72
nd
rd
and 3
sources for bit7)
st
rd
and 3
sources for bit7)
st
nd
and 2
sources for bit7)
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
All binector numbers
Ind: 2
1
FS=1
Type: L2
All binector numbers
Ind: 2
1
FS=1
Type: L2
All binector numbers
Ind: 2
1
FS=1
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=1
Type: L2
All binector numbers
Ind: 2
1
FS=1
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=1
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
SIEMENS AG
SIMOREG DC Master
Operating Instructions
05.05
See
Change
(Access /
Status)
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
6RX1700-0AD76