SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0240
User Response
1. Check the system-event log.
2. Check the PCI LED.
3. Remove the adapter from the indicated PCI slot.
4. Check for a server firmware update. Important: Some cluster solutions require specific code
levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest
level of code is supported for the cluster solution before you update the code.
5. (Trained technician only) Replace the system board.
• 806f0813-2584ffff : A Uncorrectable Bus Error has occurred on system
[ComputerSystemElementName]. (CPUs)
This message is for the use case when an implementation has detected a Bus Uncorrectable Error.
May also be shown as 806f08132584ffff or 0x806f08132584ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0240
User Response
1. Check the system-event log.
2. (Trained technician only) Remove the failing microprocessor from the system board (see
Removing a microprocessor and heat sink).
3. Check for a server firmware update. Important: Some cluster solutions require specific code
levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest
level of code is supported for the cluster solution before you update the code.
4. (Trained technician only) Replace the system board.
• 806f0823-2101ffff : Watchdog Timer interrupt occurred for [WatchdogElementName]. (IPMI
Watchdog)
This message is for the use case when an implementation has detected a Watchdog Timer interrupt
occurred.
May also be shown as 806f08232101ffff or 0x806f08232101ffff
Severity
Appendix A. Integrated management module II (IMM2) error messages