Connection for air extraction
Condensate trap
(optional accessory)
In addition to insulating the exhaust
ducting, we recommend that a suitable
condensate trap is installed to collect
and evaporate any condensate which
may occur. Condensate traps are
available for C 125 mm or C 150 mm
ducting.
When installing a condensate trap,
ensure that it is positioned vertically
and, if possible, directly above the
exhaust connection. The arrow on the
housing indicates the direction of
airflow.
28
Silencer
(optional accessory)
To achieve even further reductions in
noise levels in air extraction mode, a
special silencer can be fitted in the
ducting system.
The silencer not only reduces noise
from the motor outside the house, but
also sounds from outside (e.g. traffic
noise). For this reason, the silencer
must be positioned as close as
possible to where the ducting leaves
the building a.
The most effective noise reduction is
achieved if two silencers are installed
one behind the other.