Hardware Diagnostics

Log Utilities

03. LOG UTILITIES logs error information generated while a test is in progress. The
results are stored in RAM.
Select 03. LOG UTILITIES from the HW Diagnostics Program Main Menu to check the
error logs. The following screen appears:
The screen contains the following information:
XXXXX ERRORS shows the number of errors.
PASS COUNT is displayed if the test parameter "Test Loop" is set as "Yes" in the test.
CNT shows the number assigned according to the order of occurrence of the error.
TEST XXX XX XXX
- Where digits 1 - 3 show the abbreviation of the test in which the error occurred.
MEMORY TEST
KEYBOARD TEST
DISPLAY TEST
FLOPPY DISK TEST
PRINTER TEST
SCSI DISK TEST
- Where digits 4-5 shows the subtest number in which the error occurred.
- Where digits 6-7 shows the step number in which the error occurred.
Depending on the test, digits 6-7 are not always displayed.
PASS shows the pass count where the error occurred.
Test
Abbreviation
RAM
KBD
CRT
FDD
PRT
HDD
HW Diagnostics Program Main Menu
Test
NPX TEST
CACHE MEMORY
TEST
SCSI TEST
CD-ROM TEST
SAF-TE TEST
BMC TEST
270
Abbreviation
NPX
CAH
SCS
CDR
SAF
BMC