Dry Contact

Dry Contact is a solution for automatic control of HVAC system at the owner's best. In simple
words, it's a switch which can be used to turn the unit On/Off after getting the signal from
external sources.
How to install dry contact
[Parts of Dry contact]
Dry Contact body
Follow below procedures step 1 ~ step 4.
Step 1. Check if the power of the unit is turned off.
Step 2. Disassemble front panels and distinguish terminal block in Indoor PCB.
Step 3. Connect cable to the unit PCB(CN_CC) fully.
Step 4. Then, Insert harness to the dry contact PCB(CN_INDOOR) firmly as shown below.
- For 3 Series
CN_CC
Dry contact
CN_INDOOR
- For 4 Series
Indoor PCB
NOTE
• For more information about installing Dry Contact, Please refer installation manual provided
with Dry Contact.
• For more settings about Dry Contact, Please refer to "Dry Contact Mode / CN_CC /
CN_EXT" that installer setting part
Cable(for connecting with IDU)
Indoor PCB
CN_CC
ACCESSORIES INSTALLATION
Dry contact
CN_INDOOR
103