hit counter script

Energy State - LG THERMA V HM093MR Installation Manual

Air-to-water heat pump
Table of Contents

Advertisement

ACCESSORIES INSTALLATION
112

Energy State

This product provides energy states that enable customers to use as much as possible of their
own renewable energy. It can shift setpoints depending on input signal from Energy Storage
System (ESS) or from any other third-party device using Modbus RTU or Digital 230V inputs.
Available Energy States
There are 8 energy states available. 4 fixed and 4 customizable - each with the possibility to
enhance self consumption of renewable energy.
Battery
Energy
Command
State of
state
charge
Operation Off
1
(Utility lock)
Normal
2
Normal
Operation
Operation On
3
Recommend
Operation On
4
Very High
Recommend
Operation On
5
Very High
Commend
Operation On
6
Recommend
Operation
7
Save
Operation
8
Super Save
Heating
Setting
Range
Forced
Low
internal
Fixed
operation off
Maintain
operation
Fixed
status status
Increase 2 °C
High
from target
Fixed
temperature
Maintain
operation
Fixed
status
Increase from
0/+30
target
(Default : +5)
temperature
Increase from
0/+30
High
target
(Default : +2)
temperature
Decrease from
0/-30
Low
target
(Default : -2)
temperature
Decrease from
0/-30
Very
target
Low
(Default : -5)
temperature
Operation (standard setting)
Cooling
Setting
Range
Forced internal
Fixed
operation off
Maintain
Fixed
operation status
Maintain
Fixed
operation Status
Maintain
Fixed
operation status
Decrease from
0/-30
target
(Default : -5)
temperature
Decrease from
0/-30
target
(Default : -2)
temperature
Increase from
0/+30
target
(Default : +2)
temperature
Increase from
0/+30
target
(Default : +5)
temperature
Domestic Hot Water
Setting
Range
Forced internal
Fixed
operation off
Maintain
Fixed
operation status
Increase 5 °C
from target
Fixed
temperature
DHW Target
Fixed
80 °C
Increase from
0/+50
target
(Default : +30)
temperature
Increase from
0/+50
target
(Default : +10)
temperature
Decrease from
0/-50
Target
(Default : 0)
Temperature
Decrease from
0/-50
Target
(Default : 0)
Temperature

Advertisement

Table of Contents
loading