Installer setting (For 3 Series)

• You can set the product user functions.
• Some functions may not be displayed/operated in some product types.
Function
3 Minutes Delay
Select Temperature Sensor
Dry Contact Mode
Central Control address
Pump Test run
Air cooling set temp.
Water cooling set temp.
Air heating set temp.
Water heating set temp.
DHW Set Temp.
Screed drying
Heater on temperature
Water supply off temp.
during cooling
Tank disinfection setting 1, 2
Tank setting 1
Tank setting 2
Heater priority
DHW time setting
TH on/off Variable, heating air Heating air temperature TH On / Off Type setting
TH on/off Variable, heating
Water
Factory use only
Selection for setting temperature as air temperature or leaving water
temperature or air+leaving water temperature
Dry contact function is the function that can be used only when the
dry contact devices is separately purchased and installed.
When connecting the central control, set the central control address of
the unit.
Water pump test run
Adjusting range of 'Setting Air Temperature' in cooling mode
Adjusting range of 'Setting Leaving Water Temperature' in cooling
mode
Adjusting range of 'Setting Air Temperature' in heating mode
Adjusting range of 'Setting Heating Flow Temperature' in heating
mode
Setting DHW set temperature
Setting for using Step 1 or 2 capacity of electric
Setting outdoor air temperature where half capacity of electric heater
starts operation.
Determine leaving water temperature when the unit is turned off. This
function is used for preventing condensation on the floor in cooling
mode
Setting start/maintain time for pasteurisation
Setting pasteurisation temperature
Setting start temperature for operation
Setting maintain temperature for operation
Determine electric heater and water heater on and off
Determine follow time duration : operation time of domestic hot water
tank heating, stop time of domestic hot water tank heating, and delay
time of DHW tank heater operating
Heating Water Outlet Temperature TH On / Off Type
INSTALLER SETTING
Description
143