hit counter script

Lenovo System x3500 M5 Type 5464 Installation And Service Manual page 436

Hide thumbs Also See for System x3500 M5 Type 5464:
Table of Contents

Advertisement

Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Fan Failure
SNMP Trap ID
11
CIM Information
Prefix: PLAT ID: 0810
User Response
1. Make sure that the connectors on fan n are not damaged.
2. Make sure that the fan n connectors on the system board are not damaged.
3. Make sure that the fans are correctly installed.
4. Reseat the fans.
5. Replace the fans. (n = fan number)
• 800b050c-2581xxxx : Non-redundant:Insufficient Resources for [RedundancySetElementName]
has asserted. (Backup Memory)
This message is for the use case when a Redundancy Set has transitioned to Non-redundant:Insufficient
Resources.
May also be shown as 800b050c2581xxxx or 0x800b050c2581xxxx
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Memory
SNMP Trap ID
41
CIM Information
Prefix: PLAT ID: 0810
User Response
1. Check the system-event log for DIMM failure events (uncorrectable or PFA) and correct the
failures.
420
System x3500 M5 Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents