System time
6.1 System time setting
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
show dst info
Result
The entries for daylight saving time are displayed.
6.1.2

Commands in the global configuration mode

This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the configure terminal command to change to this mode.
Commands relating to other topics that can be called in the Global configuration mode can be
found in the relevant sections.
You exit the Global configuration mode with the end or exit command and are then in the
Privileged EXEC mode again.
6.1.2.1

time

Description
With this command, you configure the way in which the system time is obtained.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
time {manual|ntp|sntp|SINEC}
168