hit counter script

Role - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

11.1.4.1

role

Description
With this command, you create roles that are valid locally on the device.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
role <role-name> function-rights <function-rights-value(1-15)>
[description <role-description>]
The parameters have the following meaning:
Parameter
role-name
function-rights Keyword for the function rights
function-
rights-value
description
role-
description
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08
Description
Role name
Value of the function rights
Keyword for the description
Content of the description
Security and authentication
11.1 User rights management
Range of values / note
Enter a name for the role. The name must
meet the following conditions:
● It must be unique.
● It must be between 1 and 64
characters long.
-
Select the function rights of the role.
● 1
Users with this role can read device
parameters but cannot change them.
● 15
Users with this role can both read and
change device parameters.
-
Enter a description for the role. The de‐
scription text can be up to 100 characters
long.
477