Advertisement

Diagnostics
12.1 Diagnostics
The parameters have the following meaning:
Parameter
l1
l2
poe
If you do not select any parameters from the parameter list, the default value "L1 and L2" is
used.
Result
The setting for monitoring the power supplies is configured.
Further notes
You can display the current setting with the show events faults config command.
You disable the function with the no power command.
12.1.6.9

no power

Description
With this command, you disable the monitoring of the power supplies. Depending on the
hardware variant there are one or two power connectors (L 1 / L 2) and a PoE power supply.
Note
This command is not available on the SCALANCE W786-2 SFP.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
no power [{l1 | l2 | poe}}
598
Description
Monitoring of power supply 1
Monitoring of power supply 2
Monitoring of the PoE power supply
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface