hit counter script

Wlan - Siemens SCALANCE W770 Series Configuration Manuals

Simatic net industrial wireless lan ieee 802.11n command line interface
Table of Contents

Advertisement

Security and authentication

11.3 WLAN

Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no radius-server { ipv4 <ipv4-address> | fqdn-name <FQDN> | ipv6
<ipv6-address>} [primary]
The parameters have the following meaning:
Parameter
ipv4
ipv4-address
fqdn-name
FQDN
ipv6
ipv6-address
primary
For information on addresses and interfaces, refer to the section "Addresses and interface
names (Page 29)".
Result
The entry for a connection between the RADIUS client and a server or the identification as
primary server is deleted.
Further notes
You configure the connection of a RADIUS client to a server with the radius-server
command.
You show the configuration of a RADIUS server on the client with the show radius
server command.
You show the statistical information of this function with the show radius statistics
command.
11.3
WLAN
This section describes commands for configuring and managing wireless LANs (WLANs).
494
Description
Keyword for an IPv4 address
IPv4 address of the RADIUS server
Keyword for a domain name
Domain name (Fully Qualified Domain
Name)
Keyword for an IPv6 address
IPv6 address of the RADIUS server
Identifies the RADIUS server as primary
server
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Range of values / note
-
Enter a valid IPv4 address.
-
Maximum of 100 characters
-
Enter a valid IPv6 address.
-
Configuration Manual, 09/2017, C79000-G8976-C324-08

Advertisement

Table of Contents
loading

Table of Contents