Functions specific to SCALANCE
5.10 Remote capture
Requirement
You are in the REMOTE CAPTURE configuration mode.
The command prompt is as follows:
cli(remote-capture)#
Syntax
Call the command without parameter assignment:
activate-after-restart
Result
The function is disabled.
Further notes
You disable the setting with the no activate-after-restart command.
5.10.3.2

no-activate-after-restart

Description
With this command, you disable the function.
Requirement
You are in the REMOTE CAPTURE configuration mode.
The command prompt is as follows:
cli(remote-capture)#
Syntax
Call the command without parameter assignment:
no activate-after-restart
Result
Saving the configuration of "remote capture" is disabled. After a restart the configuration is rest
to the default settings.
162
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08